Standard Transformers
-
Product
Solid State Synchro Control Transformer and Solid State Resolver Control Transformer
SCT-RCT Series
-
Computer Conversions Corporation
The SCT Series are low cost, miniature, solid state control transformers designed for military and industrial control applications. They will directly replace conventional electromechanical control transformers & thus provide digital control to existing analog servo systems. They simultaneously accept a 3 wire synchro input (0) and a digital angle input (0), and provide an ouput which is the sine of the difference between these two input angles (A sin wt sin (0-0) ("wt" is the synchro excitation frequency).
-
Product
Split Core Current Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
Product
Programmable S/R Standard & Simulator
5300
Simulator
NAI’s 5300 Synchro/Resolver Standard & Simulator is a laboratory-grade, programmable instrument. This model can be used as a true Synchro/Resolver standard for calibrating and testing Automatic Test Equipment (ATE) for Calibration/Metrology Labs, and for Engineering Design and Production Test environments. It can also be used to measure Angle Position Indicators (API) and Synchro-to-Digital converters for static or dynamic characteristics. This model also may use an external reference waveform.
-
Product
Voltage Transformer
PT4
-
SHANGHAI POWOO INDUSTRY CO., LTD
- completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - the lead wire has a pin format, which makes it easy to be fixed on a PCB; - the mechanical dimensions for this series of PTs are relatively small, hence can be used an electronic component; - good linearity, high precision, wide operating range; - ABS anti-combustion plastic casing; - encapsulated with epoxy resin to ensure strong insulation ability.
-
Product
Rubidium Frequency Standards
-
Incorporating time-tested and field-proven technology, these rubidiums deliver high-precision time and frequency accuracy for measurement equipment. Products are available in VXI and PXI versions.
-
Product
Power Transformer Automatic Test Device
XD71
-
Hangzhou Xihu Electronic Institute
The device is used for power transformer power outage routine test items to do automated testing.Which is characterized by dielectric loss, insulation resistance, DC resistance, tap-changer switching characteristics, short circuit impedance and variable ratio of six test items are concentrated in an instrument,so that the instrument function, test power and test lead height fusion.Field test, just start wiring once, at the end of unplugging wiring once,the middle process by the test personnel in the computer terminal to send command control,the test system automatically completes all or part of the above test items.
-
Product
BMS Transformers
-
In large battery pack applications with daisy chain connections, the number of cells connected in series is very high, and the large voltage differences demand component-to-component isolation. The serial communication links between boards need to be isolated by transformer coupling circuits instead of capacitor coupling.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Vehicle Standard Interface
VSI-2534
-
Vehicle reprogramming tools are becoming an essential auto diagnostic tool in automotive repair shops. Technicians often come across OEM Technical Service Bulletins that require them to reprogram the vehicle with the latest OEM calibration files in order to diagnose and repair car problems such as check engine light, gas mileage, false DTCS, shifting, hesitation, rough idle, emissions quality, ABS, performance, and more.
-
Product
Cylinder Type Transformer Systems
YDTW\YDTCW Series
-
Shanghai Jiu Zhi Electric Co., Ltd.
Conventional AC test transformers are especially designed for testing objects of medium capacitance. These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers).The possibility of stacking several of these transformer modules allows reaching very high voltage levels by keeping reasonable floor space.
-
Product
Transformer Demagnetization Tester
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
Product
Standard Resistors for Temperature Measurement
-
Measurements International Ltd.
High Stability, Split Guard Circuit, Internal Temperature Sensor, Custom Values Available, Includes Calibration Data.
-
Product
Standard Series
-
TPC-100W Series offers versatile web terminals in 7", 10", 15.6" and 21" displays, designed for factory.
-
Product
Fourier Transform Infrared Spectrophotometer
IRSpirit
-
Despite their small footprint, smaller than an A3 size sheet of paper (297 x 420 mm), these models have been engineered with a wide sample compartment that accommodates existing accessories from Shimadzu and other manufacturers. This capability makes them the smallest (installation footprint) and lightest FTIR spectrophotometers in the world that can be used with optional products from other manufacturers. They also include a program, IR Pilot, with 23 application-specific workflows that can be utilized without involving any complicated parameter setup process. Customers can select from either the IRSpirit-T model, which offers sensitivity equivalent to standard Shimadzu models, or the reasonably priced IRSpirit-L model.
-
Product
Transformer Turns Ratio Meter
TTRM 101
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
NTSC Standard Pattern Generator
PG315N
-
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
Product
Transformer Test Equipment
-
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
Product
NF-Series Standard Plus Models
-
The E-DRIV® NF-Series standard plus models feature a selectable Double Hit Mode for soft joint applications and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
Uniload Voltage Transformer Test Set
2J6
-
The Type 2J6 Knopp Uniload Voltage Transformer Test Set consists of three major parts: When the Knopp Precision Transformer in the 2J6 set is compensated for, and used with, a secondary burden of 15 volt-amperes, for example, the ratio of this precision transformer is well within 0.02% and the phase angle is well within 2 minutes. The transformer, in common with other Knopp Precision Multirange Transformers, is wound so that it has practically the same ratio and phase angle accuracy on all ranges.
-
Product
Single Phase Transformer Ratio Meter
-
*Ideal for VT testing*Bushing Current Transformers (BCTs)*Higher resolution*Excitation current meter
-
Product
Standard Precision GNSS Module
AIW-210
-
M.2 2242 Key B form factorStandard Precision GNSS L1 band92 channel support u-blox NEO-M9N engine (GPS, GLONASS, BeiDou, Galileo, QZSS andSBAS)Open sky cold start 24 second / Aided starts 2 secondUSB 2.0 communication interfaceAccuracy 2.0m CEPOperating temperature: -40°C ~ +85°C / -40°F ~ 185°F
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
ANSI Relaying Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
Precision Multirange Current Transformer
P-2000
-
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
Product
Peripheral Level Transformer
-
The Peripheral Level Transformer (PLT) is an adapter module that increases the voltage of the analog inputs&outputs for easy communication with external devices. It is connected between the instrument and the periphery.
-
Product
Current Transformer Field Test Set
1043
-
The Catalog 1043 Current Transformer Field Test Set is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The tests are made without interrupting the Customer's service and while the load is on.
-
Product
Transformer Tester
-
MOTOMEA Distribution Transformer Test Systems: Routine Testing for Production (EOL) and Quality Assurance (QA). Type Testing at Laboratory (R&D)
-
Product
Standard Lifetime Measurement System
Filter-Based Systems
-
*Excitation by bh ps Diode Lasers (BDS-SM or BDL-SMN Series)*Optional: fs Fiber Laser*Wavelength Selection by Filters*Detection by bh HPM-100 Hybrid Detectors*Excellent Dynamic Range*Ultra-High Time Resolution*IRF Width Down to 40 ps FWHM with HPM-100-06/07*Low Cost Detector Option: PMC-150 PMT Modules
-
Product
PPS Clamp Transformer
-
PPS2 provides power supply to the PD detectors installed on HV cable when low voltage AC power is not available. The PPS2 takes the required power directly from the High Voltage power line under monitoring by means of units clamped on the HV power cable(s).PPS2 is designed to withstand High Voltage line failure events such as temporary overload and short circuit conditions. An internal detection and self limiting circuitry guarantees that PPS2 and the connected equipment survives in case of such events.
-
Product
AC Calibration Standard
1U647-001
-
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.