Current Loops
See Also: Loop, HIL, Loop Testers
-
Product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
-
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
Product
4-Port Serial Interface
APCI-7500-3
-
This Model has a 37-pin D-Sub male connectorRS232, RS422, RS485, 20 mA Current LoopModular structure through SI modulesWith or without optical isolationMode configuration free for each port128-byte FIFO-buffer, common interruptTransfer rate programmable up to 115,200 BaudOption: up to 1 MBaud for RS485 and RS422Automatic direction recognition for RS48Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)Transmission mode asynchronous, full, half duplexTransfer rate: progr. up to 115.2 kBaud up to 1 MBaud on requestProtocol: 5, 6, 7 or 8-bit character 1, 1? or 2 stop bitsParity: even, odd, none, mark or spaceInterrupt lines: automatic through BIOS
-
Product
16-Channel DAC Function Card
ProDAQ 3510
-
The ProDAQ 3510 DAC function card is a ProDAQ high-density card that fits into ProDAQ VXIbus motherboards and LXI function card carriers. This high-density card contains 16 independent, 16-bit DAC channels, and each channel is equipped with its own DAC. The ProDAQ 3510 DAC function card is specially designed for DC, low-frequency, and current loop applications.
-
Product
Calibrator Process
VA70034
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
Product
Analog & Digital I/O Modules
-
USB analog and digital I/O modules are a complete family of data acquisition modules for use in process control systems. The analog input modules can measure process signals such as DC voltage, thermocouples, 4-20mA current loops, discrete contact closures.
-
Product
4-Port Serial Interface, Modular, With/Without Optical Isolation, 3.3V
CPCI-7500
-
*This Model has a 37-pin D-Sub male connector*RS232, RS422, RS485, 20 mA Current Loop*Modular structure through SI modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer, common interrupt*Transfer rate programmable up to 115,200 Baud*Option: up to 1 MBaud for RS485 and RS422*Automatic direction recognition for RS48*Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)*Transmission mode asynchronous, full, half duplex*Transfer rate: progr. up to 115.2 kBaud up to 1 MBaud on request*Protocol: 5, 6, 7 or 8-bit character 1, 1? or 2 stop bits*Parity: even, odd, none, mark or space*Interrupt lines: automatic through BIOS
-
Product
Current Loop Adapter
OP-1C
-
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
PCI 8 Form C Relay Output / 8 Isolated Input Digital Interface
8011
-
The 8011 digital I/O interface provides 8 optically isolated inputs and 8 Form C relay outputs. The inputs protect the PC and other sensitive equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide higher current capabilities (up to 2A) and are optimized for 24V operation.
-
Product
PCI 16 Reed Relay Output / 16 Isolated Input Digital Interface (10-30V)
8004H
-
Optimized for sensing up to 24V inputs, the 8004H PCI digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The inputs protect the computer equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide high quality, long-life, low-current (10 Watt maximum), dry contact switch closures. The relays are normally open, and close when energized.
-
Product
H/L Voltage Clamp Meters
-
High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.
-
Product
PXI Analog Output / Current Loop Simulators
-
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
Product
Rechargeable Multifunction Tester
ET4000
-
The new ET4000 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.
Everything about the new ET Series has been designed to save time and make testing easier.
Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .
Supplied with a full range of accessories.
-
Product
4 (High Current) D/A Outputs (±40 VDC or +100 mA)
DA3
-
The DA3 module features 4 high-current D/A output channels with a full-scale range of ±40 VDC or ±100 mA (max). The DA3 provides either voltage or current control loop modes that are programmable for the particular application.
-
Product
4-20mA Current Loop USB Data Logger
EL-USB-4
-
This data logger measures and stores up to 32,000 current loop readings over flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a a 4-20mA d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista
-
Product
Opto-Isolated Current Loop Signal
4029
-
SPECTEC Innovative Sensor Solutions
SPECTEC's Model 4029 digital opto-isolated current loop signal conditioner prevents ground loops and interrupts any galvanic signals riding on magnetic speed sensor's output signal.. This signal conditioner converts magnetic, variable reluctance and inductive sensors' sinusoidal signals into a 4-20 mA output suitable for interfacing with process control units, dataloggers, flow controllers, and computers.
-
Product
4-20mA Current Loop D/A Converters
-
ADI integrated solutions combine both the D/A converter and driver in one chip to provide the required output directly from the digital domain. Analog Devices’ portfolio of leading industrial D/A converters and drivers provides a range of programmable output ranges from standard 4 mA to 20 mA for current loop communication to ±10 V for actuator control. ADI industrial converters offer considerable control functionality and advanced on-chip diagnostics to maximize system uptime, as well as eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
Product
Digital LOOP/PSC/EARTH Tester
1824 LP
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.
-
Product
PCI Express 16 Reed Relay Output
8004e
-
The 8004e PCI Express digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The isolated inputs protect the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments. The outputs provide high quality, long-life, dry contact switch closures suitable for low-current applications.
-
Product
Digital LOOP/PSC/LOAD Tester
1825 LP
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.
-
Product
Intelligent Transmitter with Digital Indication
LEO 3
-
KELLER AG für Druckmesstechnik
LEO 3 is a micro-processor based transmitter with digital double-display for pressure (top display) and for the output signal (bottom display). The display is powered from the 4...20 mA current loop. Functions:
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 16 Channel
43-765-001
-
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
-
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Loop Meter
MZC-310S
-
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
Product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
-
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
Product
4 High-Voltage/High-Current (External VCC) D/A Outputs
DA5
-
Digital-to-Analog (D/A) module DA5 provides 4 independent D/A output channels (half-bridge) utilizing a single external supplied power source with full-scale operating range of 0-65 VDC (V-control mode) and 0-2 A (I-control mode). Alternatively, two channels can be paired (full-bridge) to achieve a full-scale operating range of ±65 V and ±2 A from a single external supplied power source. Linearity/accuracy is ±1% FS range over temperature. The DA5 provides either voltage or current control loop modes, which are programmable for the application.
-
Product
Multi Function Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
Product
PAT and Installation Verification Unit
PowerCheck 1557
-
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
Product
Fuse Buddy Current Loop
307M/308B
-
*Just clamp your current probe over the loop to access the amperage draw through a fused circuit. *Easy testing access, plugs right into fuse socket, no more hand made adapters. *Testing range 0-30 Amps - Do Not Exceed 30 Amps
-
Product
Resistance Tester With Leakage Current (Loop Current)
GT00WD00ZY
-
*screen display*Double protection insulation*Non-contact measured resistance, safe, fast
-
Product
PCI Express 8 Reed Relay Output
8012e
-
The 8012e Low Profile PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.