Contamination
-
Product
Health Physics Systems
-
Detection and quantification of radioactive material within the body is a key factor in determining internal personnel contamination and dose assessment. These measurements can be made on body fluid samples using lab instrumentation or through direct measurement of personnel. The measurement of body fluids is generally less attractive due to the bio-hazards and lack of immediate results unless non-gamma emitting nuclide measurements are required. The direct measurement of personnel for gamma emitting radioactive material provides rapid results, can determine where the material may be located within the body, and does not require mobility of the material through body fluids for detection.
-
Product
Low-Noise DC Bias
-
Imaging devices, such as CCDs, IR FPAs, and CMOS image sensors, require DC bias with very low electrical noise to prevent contamination of the image. Image quality can also be enhanced by carefully tuning each bias voltage to extract the maximum signal/noise ratio out of an array. Pulse Instruments has decades of experience providing DC bias supplies with the flexibility required tocharacterize and test a variety of devices while maintaining the noise immunity required for satellite and astronomy applications.
-
Product
Total Reflection X-ray Fluorescence (TXRF) Services
-
A highly surface-sensitive technique, TXRF is optimized for analyzing surface metal contamination on semiconductor wafers.
-
Product
Universal Differential pH Water Quality Sensors
SD7500CD
-
Continuous online pH monitoring in wastewater and coating industrial applications leads to contamination and eventually requires sensors to be replaced. A differential pH sensor utilizes a measurement technique designed to extend the working lifetime of sensors in challenging applications. Replacing the sensor reference (salt bridge) and buffered electrolyte solution can prevent sensor replacements, saving time and money. Our SD7500 Series features a combination sensor output; these differential pH sensors can be used with any conventional pH/ORP transmitter.
-
Product
Contaminometer
Conttest
-
Microtronic Microelectronic Vertriebs GmbH
Ionic contaminants can have a major negative impact on the reliability of assemblies. It therefore makes sense to check the assemblies for ionic contamination in the development stage and in the manufacturing process.The devices of the ConTTest series measure ionic pollution in accordance with international standards. The high-precision measuring system was designed to serve as a process control in production and to be used as a laboratory instrument in development and research.
-
Product
PAMAS Sensors
-
PaMas Partikelmess- und analysesysteme gmbH
High-precision, German-engineered laser-based instruments designed to measure solid particle contamination in liquids.
-
Product
Pass-Through Oven
UF TS
-
The Memmert heating oven with fully insulated stainless steel door on both sides saves time during loading and reduces the risk of contamination, specially when handling sensitive load between grey and clean rooms. On this page, you can find all the essential technical data on our pass-through oven. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at
-
Product
Stealth Laboratory/QA Metal Detector
-
Stealth Laboratory metal detectors are manufactured to suit any application. Designed to be used in offline product examination to assist in determining contaminant source. Stealth detectors use digital signal processing technology and have high sensitivity levels to ensure the detection of the smallest ferrous, non-ferrous and stainless steel contaminants. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Omicron Fiber Optic Connector
-
Teledyne Impulse-PDM’s Omicron 5030/5070 optical connectors utilize proven small form factor ferrule technology and are available for multi-mode or single-mode operation.The connectors are offered, as standard, in stainless steel to BSEN10088-3 Grade 1.4404 (316L), which is electro-polished to remove surface contamination, thus improving resistance to corrosion. Connector bodies can also be manufactured in other materials, either to address specific anti-corrosion requirements, or to increase depth rating. Engaging nuts are normally manufactured in naval brass to UNS C46400.
-
Product
Atmospheric Pressure Gas Analyzers
-
The Cirrus™ single-quadrupole mass spectrometers are powerful analytical tools for a wide range of laboratory and industry-based gas analysis applications. The Cirrus family, featuring the Cirrus™ 3 and Cirrus™ 3-XD atmospheric pressure gas monitoring systems are ideal for analysis of bulk gas, gas composition, and detection of trace gasses and contamination. These powerful, versatile and customizable platforms, when combined with Process Eye™ Professional software and its recipe-based control, can significantly boost your productivity.
-
Product
Multi-Mode And Single-Mode Applications
Expanded Beam Size 5 and 12 Contacts
-
Expanded Beam Fiber Optic Contact technology is specifically designed to fit into standard size 12 cavities of MIL-DTL-38999 Series I, III and IV connectors. The size 12 contact provides a robust fiber optic interconnection with low susceptibility to contamination and fits a variety of cable types with diameters from 1.6 to 2.2 mm with additional versions available upon request. The contacts are rear release/rear removable with standard size 12 removal tool.
-
Product
Surface Cleanliness
-
Surface cleanliness: Soluble salts & ion specific contamination (sulphates, chlorides, nitrates etc.) which are often invisible to the eye, together with amine blush (for amine cured epoxy coatings) can result in premature coating failure, resulting in high re-coating and maintenance costs. Elcometer has a range of test equipment for assessing surface cleanliness prior to applying a coating.
-
Product
Surface Cleanliness
-
Surface cleanliness: Soluble salts & ion specific contamination (sulphates, chlorides, nitrates etc.) which are often invisible to the eye, together with amine blush (for amine cured epoxy coatings) can result in premature coating failure, resulting in high re-coating and maintenance costs. Elcometer has a range of test equipment for assessing surface cleanliness prior to applying a coating.
-
Product
Phantom Pharmaceutical Metal Detector
-
The Phantom Pharmaceutical metal detector provides the ideal solution for detection and rejection of the smallest contaminants in tablets and capsules. With its current GMP design and construction suited for FDA compliance, the system meets the stringent QA requirements of the pharmaceutical industry. A free IQ/OQ Validation package is included. Built with a rugged mirrored stainless steel exterior, contact parts are all removable for cleaning without the need for tools. This compact detector can be easily angled and height-adjusted to suit any press configuration. Plus, it’s the only detector that features an electrical powered lift.
-
Product
Metal Detector
Safeline Profile Advantage
-
For challenging inspection applications where a product is wet, hot, chilled or cooling Profile Advantage technology provides the ultimate in metal contaminant detection capability. All metal contamination including ferrous, non-ferrous and even the most difficult to detect non-magnetic stainless steels are readily detected enabling them to be removed effectively from the manufacturing process.
-
Product
Stealth Pipeline Metal Detector
-
Stealth Pipeline metal detectors are custom manufactured to suit any piped product application. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous, non-ferrous and stainless steel contaminants. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Abrasive & Blast Inspection
-
Blasting parameters: A number of important parameters need to be monitored during the blasting or water jetting process, these include: air pressure (at the nozzle), nozzle diameter, blast media contamination & pH values in order to avoid recontamination of the substrate during blasting.
-
Product
Phantom Laboratory/QA Metal Detector
-
The portable and compact Phantom Laboratory Metal Detector is used offline to further examine rejected product from an in-line Large Bag or Gravity detection system. The Lab unit enables you to quickly filter out the metal contaminants and reclaim good product. Additionally, by isolating the contaminant QA can then determine the source of the problem and initiate corrective action. Equipped with a floor stand and castors, the Laboratory detector is easy to move from room-to-room. The ergonomically designed hopper offers a user-friendly means of hand-feeding product through its plastic pipe section. Two bins for Good product and Rejected product are also included with the system.
-
Product
Ionizers
-
Panasonic Automotive & Industrial Systems Europe GmbH
There are many production processes where electrostatic charges disturb smooth operation. To eliminate static, ionizers are used. One typical field of application is the semiconductor industry where the components are extremely sensitive and can even be damaged by high electric static charges. Another example is the printing industry: Here friction between the rollers and the paper generates static. The static makes the paper cling and not move correctly through the printing machine. Especially when printing on vinyl or plastics, electrostatic charges need to be removed. In the packaging industry, plastic sleeves or foils tend to stick to each other, which can be prevented with an ionizer eliminate static. A general problem in assembling processes is the adhesion of dust and dirt particles. Contamination of workpieces can be prevented by having static eliminators neutralize and blow away undesired particles.
-
Product
Dissolved Ammonia Delivery System
DI-NH3
-
MKS' DI-NH3 is a compact, stand-alone system providing dissolved ammonia water. With Semiconductor 3D IC architectures using new materials like Cu-Co and Si-SiGe, the ability to wet clean with precise alkaline chemistries is growing in frequency and importance. The DI-NH3 delivers dissolved ammonia, providing optimal cleaning capability in an alkaline chemistry, minimizing material loss and contamination and inhibiting Electrostatic Discharge (ESD). Using closed-loop control, conductivity and pressure are kept stable under changing flow conditions. The dissolved ammonia concentration is monitored and adjusted, delivering the specific NH4OH concentration needed. Dissolved ammonia’s alkaline chemistry provides ESD protection during rinsing, particle lift-off, and residual photoresist removal in middle-of-line (MOL) and prevents corrosion of cobalt/copper interfaces.
-
Product
Integrated Displacement Sensing
IDS3010
-
With its slim size, the IDS can be directly integrated into machines for free-beam operation and is the product of choice for challenging OEM & synchrotron applications. A passively cooled housing prevents contamination of optical and electrical components.
-
Product
Oil BDV Tester
-
Weshine Electric Manufacturing Co., Ltd
Insulating oil in electrical power apparatus serves two primary roles, as an insulator and a coolant. As an insulating liquid, oil’s most important property is a high dielectric strength and as a cooling liquid, a low viscosity is paramount. The principal nemeses of insulating oil are oxidation, contamination (particularly moisture, which tends to lower the dielectric properties of insulating oil), and excessive temperature.
-
Product
Surface Contamination Monitors
-
Small-sized devices for measuring the ambient dose equivalent rate and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130).
-
Product
Software
MOS Capacitance-Time Measurement and Analysis
-
Materials Development Corporation
The Capacitance-Time transient resulting from an MOS device pulsed into deep depletion reveals important information about bulk properties of the semiconductor and about damage or contaminants introduced during processing.
-
Product
Pulse AC Method Area Ionizers
ER-X Series
-
Panasonic Industrial Devices Sales Company of America
The ER-X Series Area Ionizers utilize the pulse AC ionization design to achieve high-speed charge removal of wide surface areas for high-volume production lines. In addition to supporting compressed air ionization, the ER-X also features both airless and low-pressure ionization modes for applications where tiny workpieces can be easily blown away. Additional features include automatic ion balance and discharge frequency control (manual control is also possible), flat discharge surface for easy cleaning, discharge needle air barrier design to reduce contamination of the needles, replaceable discharge needle unit for easy maintenance, and a dual head configuration for enhanced charge area and layout (2 different ionizer heads can be connected to a single controller).
-
Product
Bench Top Ionizers
-
Point-Of-Use Ionizer, Adjustable (30-100 PSI) Compressed Air IonizerNeutralize Electrostatic Attraction (ESA) to control contamination by dislodging dust and debris attracted by static electricity.Detachable 7'' long ESD Protective Flexible Hose with Thumb Button Designed to for a wide range of motion and simple operation.Adjustable Balance (20 Volts) with Less Than 1 Second Discharge Time At 6 InchMeets required limits ANSI/ESD S20.20 tested per ANSI/ESDSTM3.1 and ESD TR53
-
Product
Stealth Metal Detector
-
Stealth metal detectors are custom manufactured to suit any application. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous, non-ferrous and stainless steel contaminants. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Slip Testing (Articulated Strut) (Mark II)
SG-P07MII
-
It's used to determine the slip resistance of footwear sole, heel or related materials against planar walkway surface or walkway surrogates under dry, wet or contaminated conditions.
-
Product
Ammonium Logger Sensor
NUL-240
-
The NeuLog ammonium sensor can be used to measure the concentration of ammonium ions (NH4+) in aqueous samples. It can be used to evaluate the degree of contamination of water due to the use of fertilizers.Ammonium measurements can also be very relevant to study the nitrogen cycle in general and to relate this cycle to plants and algae.
-
Product
Ozone Gas Delivery Systems
-
MKS ozone gas delivery systems provide field-proven, high concentration, ultra-clean ozone generation for advanced thin film applications such as Atomic Layer Deposition (ALD), Chemical Vapor Deposition (CVD), Tetraethyl Orthosilicate (TEOS)/Ozone CVD (HDSACVD), contaminant removal and oxide growth. Gas delivery models have integrated ozone concentration monitoring, flow control, and power distribution. Additional system options include safety monitoring, status indicators and ozone destruction capability.





























