Contamination
-
Product
Multi-Analyte Testing Solutions
-
Aflatoxins, Fumonisins, Vomitoxin (DON), Ochratoxin A, Zearalenone, Nivalenol, T-2 and HT-2 are the primary targets for mycotoxin analysis for food and agricultural analytical testing laboratories. Global awareness, prevention based initiatives and strict regulatory limits require a deeper understanding of both the occurrence and contamination levels present in our raw materials, processes and finished product value streams. Simultaneous sample prep enables more efficient use of laboratory resources while reducing time to result for up to 13 mycotoxins in a single LC or LC/MS/MS analysis.
-
Product
Silver Ball Matrix Sockets
-
SM Contact is a unique contact that has precise silver balls held together by a proprietary conductive formulation. These conductive columns (diameter optimized for 50 ohm impedance) are suspended in a non-conductive flexible elastomer substrate with a patented solid core for enhanced durability and reliable performance over time, temperature and cycles. This flexible substrate is very compliant and resilient and enables the conductive columns to revert back to original shape when the force is removed. Solutions are available for 0.25mm to 1.27mm LGA, BGA, QFN, CSP, POP, WLP and other packages. The silver ball matrix contact technology is also available with a protective plunger matrix (a gold plated copper cylinder) that sits on top of the conductive columns. This plunger matrix protects the conductive column from contamination from various solder ball interfaces. A quickly replaceable plunger matrix enables minimal downtime during final production test. The product family code for this line of sockets is SMP.
-
Product
Stealth Vertex Metal Detector
-
Stealth Vertex metal detectors are custom manufactured to suit any inline processing application where space is limited. The ultra-slim Vertex detects metal contaminates in free-falling product prior to final packaging. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous, non-ferrous and stainless steel contaminants. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Airborne Particle Counters
-
Complete contamination control solution including cleanroom certification and clean area monitoring, while meeting global requirements for data integrity.
-
Product
PXI 8 Channel Switch Simulation Module
40-480-021
Switch Simulation Module
The 40-480 is designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions.
-
Product
2100Vdc Screw Terminal Connector Board | Cable & Harness Tester
CB29H
-
CAMI Research Inc. (Acton, MA) announces another new board for its CableEye cable and harness testing systems. Populated with four 16-pole screw terminal blocks, the board addresses high voltage (HiPot) testing to 2100Vdc/1200Vac. Of particular interest to the harness testing market, the CB29H is also available as a transition board variant (CB29AH). The CB29H and CB29AH boards are high voltage versions of the CB29 with the high voltage traces running on inner layers to afford additional safety, and protection from contamination.
-
Product
Metal Detection Pipeline System for Vacuum Fillers
HDS
-
Metal detection systems for sausage manufacture and inspection of high viscosity liquids. The maximum capacity to detect all metal contaminants combined with stable on-line performance. Full stainless steel construction and sealing standards up to IP69K make HDS pipeline detectors suitable for the harshest meat processing environments.
-
Product
Sample Pretreatment For Optical Emission Spectrometry
-
Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.
-
Product
Chloride Ion Test Kit for Abrasives
134A
-
Contamination can build up, particularly if the blast media is recycled several times. Using the Elcometer 134A Chloride Ion Test in the field will accurately identify contamination and prevent costly surface-related failures.
-
Product
Switch Mode Power Supplies-Water Cooled
-
The MSW Rectifiers are based on Switch Mode Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%.The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.
-
Product
Stealth In-Foil Metal Detector
-
Stealth In-Foil metal detectors are custom manufactured to suit any foil packaging application or aluminum casting inspection. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous contaminants, despite the presence of foil packaging. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Certified Sanitary Inline Refractometer | 2″ Tri-Clamp
VIP2-3A
-
3-A Sanitary Refractometer for Food & Product Safety: Driven by concerns over food and product safety in the dairy, food, beverage, and bio-pharmaceutical industries, 3-A certified sanitary refractometers must meet exacting hygienic standards before they are awarded certification, one of the top honors attainable in the field of refractometry. Needless to say, refractometers carrying the 3-A seal meet the highest level of professional standards for the protection of public health by offering the maximum degree of protection against food or product contamination, resulting in product contact surfaces that can be easily cleaned and sanitized.
-
Product
Cleanroom Testing
-
MicroStat Laboratories -R.E.T.S.
We utilize the relevant test methods and standards set forth by the ESD Association, ANSI, ASTM, NFPA, IEST, IEC, ISO, or our clients’ in-house specifications. ESD testing is performed in-house; other testing can be arranged through sub-contractors with interpretation of results performed by experienced contamination control experts..
-
Product
Handheld Infrared Oil Analyzer
FluidScan® 1000 Series
-
The FluidScan® 1000 series handheld Infrared oil analyzer provides direct quantitative measurement of a lubricant’s condition and plays an important role in Machine Condition Monitoring (MCM) for proactive and predictive maintenance in Reliability Management programs. It determines when oil needs to be serviced due to degradation of the oil chemistry or contamination by other fluids such as water or the wrong oil. It is compliant with ASTM D7889 “Standard Test Method for Field Determination of In-Service Fluid Properties Using IR Spectroscopy”.
-
Product
Optical 12,000 Meter Connector
-
Teledyne Impulse-PDM’s 5135/5175 optical connectors utilize proven standard ferrule technology and are available for multi-mode or single-mode operation.The connectors are manufactured in Titanium Ti 6Al-4V, which is electro-polished to remove surface contamination, thus improving resistance to corrosion. The engaging nuts are also manufactured in the same grade of Titanium and the threads are coated with a Nickel/PTFE composite coating to prevent galling. The connectors have been qualifi ed to 12,000 meter operating depth.
-
Product
EDXIR-Analysis Contaminant Finder/Material Inspector
-
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues identification results and the degree of matching. it can also be used to perform EDX or FTIR data analysis on its own. The library used for data analysis (containing 485 data as standard) is original to Shimadzu, and was created through cooperation with water supply agencies and food manufacturers. Additional data can be registered to the library, as can image files and document files in PDF format. It is also effective for the linked storage of various types of data as electronic files.
-
Product
Sample Holder/Stocker For Contaminant Measurement
EDXIR-Holder
-
Measure the Samples Kept in the Holder with EDX and FTIR The Holder Can Be Used as the Sample Stocker after the Measurement
-
Product
On-site Oil Analyzer
MicroLab 30
-
MicroLab 30 is designed for fleets operating over-the-road vehicles or generator equipment. This analyzer best suited for companies interested in testing primarily engine oils to determine the serviceable life of the oil and the equipment condition. The MicroLab 30 analyzes six oil chemistry parameters along with viscosity to determine proper drain intervals. The standard 10 element version provides information on oil contamination and wear metal analysis to determine if mechanical issues exist. The MicroLab 30 can be upgraded to 20 elements if there is an interest to analyze oil additive levels as well as additional wear metals.
-
Product
Thin Films, Plasma and Surface Engineering
-
A residual gas analyser for vacuum process analysis. Measures the vacuum process gas composition, contamination and leak detection.
-
Product
On-Stream Analyzer
Boxray 24
-
For many concentrator plants. The on-stream analyzer Boxray 24 consists of a carousel equipped with 24 measurement cells. This enables a single analyzer to monitor multiple sample streams and process steps, from ore to concentrate and tailings. As each stream has its own loop and measurement cell, there is no risk that samples will be contaminated by other streams, which can corrupt analysis results.
-
Product
Molecular Contamination
-
Ion mobility spectrometers detect and alert users to small concentrations and changes in airborne levels of chlorides, acids, amines, and ammonia-containing species.
-
Product
Elcometer Bresle Patches
135B
-
Elcometer 135B Original Bresle Patches are used to determine surface chloride contamination and are self-adhesive rubber film patches with a sealed compartment for sampling soluble impurities from steel surfaces with a suitable solvent.
-
Product
Digital Inspector
DI-2000
-
Many modern network issues can be traced to contaminated or damaged fiber optic connector endfaces. Lightel’s DI inspection probe series provides ergonomic, easy-to-use, and versatile inspection of the endfaces for fiber optic male and female, single and multi-channel connectors.
-
Product
Liquid Thermal Shock Baths
TSB Series
-
CSZ's Liquid thermal shock chambers consist of separately controlled hot and cold baths. Product is submersed in fluid and thermally stressed between the hot and cold baths, resulting in immediate product temperature changes. CSZ uses perfluorinated fluid that does not coat the product or conduct electricity for use in both the hot and cold baths to eliminate cross contamination and reduce evaporation losses.
-
Product
Sulphur Dioxide Test Chambers
-
The Sulphur Dioxide Test Chambers from Weiber are Corrosion Test Chambers used for testing the corrosion resistance of metallic surfaces and outer protective layer of coatings. They are used to create a highly corrosive environment rich in corrosive gases and natural humid conditions to induce accelerated corrosion in protective coatings of machines and equipments, electrical items, electronic parts and components, mechanical constructions, automobile and aircraft parts and components etc. Since the corrosive action of Sulphur dioxide also depends on specific temperature and humidity conditions and the presence of other contaminants, the Weiber Sulphur Dioxide Test Chambers are designed to create optimal conditions of temperature and humidity and also make provisions for introducing impurities and contaminants. These equipments operate across a wide temperature range, creating variations in the working temperature to mimic a natural weathering environment.
-
Product
Particle Impact Noise Detection (PIND) Test
-
This test detects the presence of free moving particulate contaminants within sealed cavity devices. This test is specifically directed toward relays and other devices where internal mechanism noise makes rejection exclusively by threshold level impractical. This test method also may be used prior to final sealing in the manufacturing sequence as a means of eliminating loose particles from the interior of the device.
-
Product
SparkFun Air Quality Sensor
SGP40 (Qwiic)
-
The SparkFun SGP40 Air Quality Sensor provides a measurement of the quality of the air in your room or house. The SGP40 is based on Sensirion's CMOSens® technology and uses a metal oxide (MOx) sensor with a temperature controlled micro hotplate and provides a humidity-compensated volatile organic compound (VOC) based indoor air quality signal. Both the sensing element and VOC Algorithm feature an unmatched robustness against contaminating gases present in real world applications enabling a unique long term stability as well as low drift and device to device variation.
-
Product
First Trip Testing of Circuit Breakers
-
Significance of Circuit Breaker "First Trip Time"A circuit breaker may not be called upon to operate and clear a fault for years, but when a fault occurs, it is expected to operate within it's published time-current characteristics. Unfortunately, frequently this does not happen... environmental contaminants, hardened grease, vibration and other factors can adversely affect the operating time of the circuit breaker.
-
Product
Ionic Contamination Test Equipment
-
For manufacturers driven to deliver quality products, SCS Ionic Contamination Test Systems are the industry standard, delivering accuracy and performance in a range of configurations.





























