Total Harmonic Distortion
Is a measure of a signal's sum power of all harmonic components to the power of the fundamental frequency.
See Also: Distortion, Intermodulation Distortion, THD
-
Product
Modulation Distortion Up To And Beyond 125 GHz
S930713B
-
S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Total Organic Carbon Monitor
HT-110
-
The continuous online TOC-Analyzer HT-110 is suitable for the measurement ot total organic carbons in Purified Water (PW), Water For Injection (WFI) and Highly Purified Water (HPW). The unit is operating according to USP 643. It is applicable for pharmaceutical and/or semiconductor manufacturing. The measuring principle is based on UV-Oxidation and measurement of the difference in conductivity. TOC concentration measurement (TOC concentration 500 ppbC or lower) is necessary to perform quality control according to GMP (Good Manufacturing Practice).
-
Product
Total Organic Carbon Analyzer
TOC-L Series
-
The TOC-L series of TOC analyzers adopts the 680°C combustion catalytic oxidation method, which was developed by Shimadzu and is now used worldwide. While providing an ultra wide range of 4 μg/L to 30,000 mg/L, these analyzers boast a detection limit of 4 μg/L through coordination with NDIR. This is the highest level of detection sensitivity available with the combustion catalytic oxidation method. In addition, the combustion catalytic oxidation method makes it possible to efficiently oxidize not only easily-decomposed, low-molecular-weight organic compounds, but also hard-to-decompose insoluble and macromolecular organic compounds.
-
Product
Total Sulfur Analyzer
Model 6200T
-
Teledyne Analytical Instruments
The Model 6200T Total Sulfur Analyzer utilizes proven UV fluorescent technology to continuously detect sulfur found in inert gas streams. An internal, quartz catalytic converter is employed to convert the sulfur, when mixed with scrubbed ambient air, into SO2 via higher temperature oxidation. An internal vacuum pump is employed to draw both the sample and the ambient air into the converter. The converted sample gas is fed to the fluorescence chamber where it is then exposed to ultraviolet radiation.
-
Product
Waveguide Harmonic Mixer, 33 to 50 GHz
11970Q
Harmonic Mixer
The Keysight 11970Q waveguide mixer is a general-purpose harmonic mixer employing a dual-diode design to achieve flat frequency response and low conversion loss. These are achieved without external dc bias or tuning stubs. Manual operation and computer-controlled hardware operation are simplified because mixer bias and tuning adjustment are not required.
-
Product
pH and Free & Total Chlorine PRO Photometer
Mi411
-
Milwaukee MI411 PRO Photometer is for users demanding fast, reliable, repeatable results with ease of use.
-
Product
Total Nitrogen Unit For TOC-L Series
TNM-L
-
Perform simultaneous TOC and TN measurements. *720 °C catalytic thermal decomposition/chemiluminescence methods are adopted for TN measurement. There is no interference from metallic ions or bromine in sea water.*Measurements over a wide range with a detection limit of 5 μg/L for TOC-LCH to an upper limit of 10,000 mg/L.
-
Product
Totalizer (pulse input)
-
Two independent scalable pulse-input channels. Count up or down to a preset at rated up to 1 MHz. Scaled rate and total from the same electronic counter. Scaling for direct readout in engineering units, such as gallons or cubic feet based on counts from a turbine flow meter. One channel can display total while other displays rate.
-
Product
Total Nitrogen Analyzer
QuickTON
-
The QuickTONb from LAR AG provides rapid nitrogen analysis
-
Product
Total Solution
SD 4.1 Family
-
To meet the ever increasing data transfer rate in high end applications, such as professional broadcasting transmission or advanced high resolution display, the SD 4.1 specification calls out the maximum performance of 1.56 Gbps at UHS-II full duplex mode per lane or half duplex UHS-II at 3.16 Gbps. In real applications, due to the system overhead and different SD 4.1 device controller designs, the actual measured performance can vary dramatically from system to system. With the newly introduced ADMA 3, the OS driver is now able to issue multiple read or multiple write commands at once, without having to wait for the SD controller to complete one command at a time. Once the SD host controller has collected multiple commands, it will then manage and complete them without intervention from the host software drive. Thus, the UHS-II 1.56 Gbps interface can be more effectively utilized and maximize the system throughput. This feature can be very useful when running multithreaded applications where multiple applications are constantly updating their status or swapping their contents by writing or reading small chunk of data to or from the memory card.
-
Product
Total Hydrocarbon Analyzer
Model 4030
-
Teledyne Analytical Instruments
The Model 4030 uses a field proven FID detector in a heated chamber. The chamber is heated to a high temperature to meet US EPA requirements for VOC emissions monitoring.
-
Product
LV Iron Core Harmonic Filters
-
Nonlinear loads such as power electronics based equipment and electric furnaces are sources of harmonic currents leading to harmonic distortion, which is one of the most important parameters for defining the power quality. Most of the commercial loads such as personal computers, photocopy machines, power supplies, and compact fluorescent lamps; and industrial loads such as AC and DC motor drives inject harmonic currents into the network that they are connected to.
-
Product
Harmonic Trap Inductors
-
Osborne designs harmonic trap inductors to work in conjunction with capacitors in power systems to prevent specific line-frequency harmonics from flowing back to the power source (point of common connection). This power quality design approach prevents harmonic currents from flowing to the main facility power system and/or to the utility power system. The Osborne system also reduces unnecessary power losses and power-system pollution.
-
Product
Harmonic Mitigation Transformer
-
A specialized three-phase transformer designed to reduce harmonic distortion and voltage distortion caused by non-linear loads (e.g., computers, VFDs) in electrical distribution systems.
-
Product
Modulation Distortion Up To 50 GHz
S930705B
-
S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Analyzer for Total Sulfur
FGA-1000
-
ATOM Instrument offers the most versatile total sulfur analyzers available. The ATOM FGA-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of applications such as monitoring refinery flare gas and subsequent sulfur dioxide (SO2) emissions as mandated by the EPA Rule 40 CFR 60, Subpart Ja.
-
Product
Waterproof High Range Total Dissolved Solids Pen (TDS)
T76
-
The Milwaukee T76 Waterproof High Range Total Dissolved Solids (TDS) Pen is designed for, aquariums, aquaculture, education, pools, water conditioning and many other applications. The T76 helps you make sure that your fish have the right TDS balance to help them stay healthy. TDS also help keep filters up-to-date and clean for water filtration or pools. Keep TDS in your target range to help your achieve better results.
-
Product
Ubuntu Total Solutions
-
The Ubuntu is a reliable, secure, and versatile environments for use, it gives unparalleled freedom and control which continues to expand into IoT.
-
Product
Analyzer for Total Sulfur in Gas Application
TRACE S- 1000
-
The ATOM TraceS-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.The Model TraceS-1000 with EUVF is a field proven technology that utilizes an excitation wavelength that achieves high detection sensitivity and detector stability. The TraceS-1000 is an excellent fit for applications in the 0-1ppm range and is exceptionally stable, even at concentrations less than 1 ppm. The TraceS-1000 is designed for outdoor installation and use in harsh environments as may be required by the refining (LPG), gas processing (NGL) and natural gas industries.
-
Product
Intermodulation Distortion Measurements
S93087B
-
The S93087B intermodulation distortion (IMD) measurement makes it very easy to set-up and calibrate swept IMD measurements with a spectrum-analyzer-like display. Not available with Option 200, 210, 400 and 410.
-
Product
Intermodulation Distortion Measurements For P50xxA/B Streamline Series VNA
S97087B
-
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S97087B software application with the P50xxA/B Streamline Series VNA
-
Product
Digital Harmonics Clamp Tester
HWT-301
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Harmonics and leakage current measurements.*Up to 25th harmonics current and voltage measurements.*True rms reading for ACA and ACV.*Data-hold and Auto power off function.*Conform to IEC safety requirements.
-
Product
Total Sulfur Process Analyzer
NEX XT
-
Applied Rigaku Technologies, Inc
Featuring third-generation X-ray transmission technology, the NEX XT represents the next evolution of process gauge for sulfur measurement (0.02% to 6% S) of crude, bunker fuel, fuel oils, and other highly viscous hydrocarbons, including residuums.The Rigaku NEX XT system is faster, more sensitive and far more compact than competitive systems, and provides continuous, reliable detection of sulfur at pressures up to 1480 psig. Rigaku NEX XT can operate as a stand-alone analyzer or provide real-time closed-loop control when tied into a blending or plant-wide automation system. Among its other key features are a simplified user interface, reduced standards requirement, automatic density compensation, password protection, and standard platform for communicating sulfur and density to a plant-wide DCS. Due to its unique design and robust construction, sample conditioning and recovery systems are typically not required.
-
Product
Total Reduced Sulfur System
ML670
-
The ML®670 Total Reduced Sulfur (TRS) system provides an accurate and convenient method of measuring Total Reduced Sulfur required for Emission Monitoring. The TRS system uses our specially designed TRS Dilution Sampling System combined with the T-Series® TRS analyzer to provide reliable TRS measurement. This system can be configured as an Open Architecture Design for ease of maintenance.
-
Product
Modulation Distortion Up To 70 GHz
S930707B
-
S930707B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 70 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930707B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Microprocessor Multifunction TRMS Power Meter + Harmonics Analyzer
8100 C
-
Kusam Electrical Industries Limited
INPUT :• Input Voltage Range :Voltage: 55 ~ 300V AC, or 300 ~ 600V AC, 45 ~ 65Hz.P.T. Ratio Programmable upto 9999 / KV.• Input Voltage Over Range :Voltage : 200 % Continuous, 300 % of rating for 10 sec.• Input Current Range :Current : 110 % of rating. 0-1A or 0 - 5AC.T. Ratio programmable upto 9999 / 5A.Input Current Over Range:Current : 400 % Continuous, 2000 % of rating for 10 Sec.• Input Frequency : 45 Hz ~ 70 Hz.• Input Burden :Voltage 0.25 VA / Unit, Current 0.25VA / Unit, at 50 / 60HzOUTPUTDC Current: 0 20 m A DCLoad resistance drive: output drive 10 V DC maximum.DC Voltage: 0 -10 V DCLoad resistance drive: output drive 5mA maximumOutput Protection: No damage even if output is Open or Short Circuit.Output Response Time : £ 1 Sec.Digital Output : RS485 Output, Isolate Type with MODBUS RTU mode., 4800, 9600,19200Baud Rate, User Selectable.
-
Product
Harmonic Filter Resistors
-
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Conductivity and Total Dissolved Solids (TDS) Pocket Water Meter
LAQUAtwin EC-33
-
The only pocket meter that directly measures conductivity and total dissolved solids (TDS) in 0.12ml sample. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample.
-
Product
Total Stations
Zoom40 Series
-
The Zoom40 manual total station, with its high resolution color and touch display, gives you the flexibility to run X-PAD, Field Genius, SurvCE, or any custom windows CE software.