Winding Ohmmeters
-
Product
Tap Changer Analyzers & Winding Ohmmeters
-
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
Product
Motor Winding Ohmmeter
RMO-M Series
-
The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
Ohmmeter
PDRM-10A
-
The PDRM-10 A ohmmeter, with a range of 0.01µΩ to 200 Ω is currently the most accurate and highest resolution ohmmeter on the market, and at only 860 g it is also the lightest and most compact. All this has made it the standard low resistance ohmmeter in many electrical companies, industries and assembly companies. It has a resolution of 0.01µΩ.
-
Product
Ohmmeters
-
GAOTek provides state of the art, professional grade Ohmmeters for sale to the United States, Canada and Globally. GAOTek Ohmmeters are portable instruments that accurately measure electrical resistance between two points on a circuit. The Ohmmeters have their own power supply through their own battery, and are needed when the two probes (red: positive side of circuit, black: negative side of circuit) are connected to the two points in the circuit where the desired measurement is to take place. The circuit is turned off, which is when the ohmmeter sends its own current through the circuit. Units of Ohms, symbolized by the Greek letter Ω (Omega), are used as a unit of measure when measuring electrical resistance. In accordance with Ohm’s law, when the current is passing through a circuit is at its maximum, the resistance is said to be the smallest.
-
Product
MICRO OHM-METER
UONT100A
-
International Biological Laboratories
This Test Set is capable to measure low resistance like switch contacts, breaker contacts, busbar splices, joints, fuses, low inductive windings etc. by circulating high value of D.C. through the contact/junction and measuring D.C voltage drop (4 terminal method) which, sent to instrument amplifiers , thereby being displayed on resistance meter.
-
Product
Wind Sensors
FT702
-
The current version of the FT702 is Version 22. Its strength and dependability have made it particularly popular for wind turbine control. It is used globally by the world's leading wind turbine manufacturers, as well as in a range of meteorology applications.
-
Product
Digital Micro Ohmmeters
-
Our micro-processor controlled range of units offers the testing capability of up to 600 amps DC with 0.1μΩ resolution. Auto-ranging metering simultaneously displays all three parameters (mV, A, and μΩ).
-
Product
Live-Line Micro Ohmmeter
Ohmstik Plus
-
The Ohmstik Live-Line Micro Ohmmeter measures the micro-ohm resistance of conductors, connectors, splices and switching devices positioned directly on an energized, high voltage lines. This measurement is much more direct than infrared thermography, and is not subject to emissivity, weather, current loading, background, and other influences that cause infrared errors.
-
Product
Compliance Voltage Ohmmeter
ΩhmRanger-LCV
-
ΩhmRanger-LCV is an accurate, 3.5 Digit, Low Compliance Voltage Ohmmeter. It is able to measure from >100M to 10 Ohms, ΩhmRanger-LCV is suitable for professionals and enthusiasts alike.
-
Product
Precision Micro Ohmmeter
BS407
-
High basic accuracy of 0.1%Wide range of 1 µΩ to 20 kΩCurrent reversal switch for detecting thermal EMF effectsCurrent diversion switch for easy zeroingFour terminal measurement using Kelvin clip leads (supplied)Battery operation with built-in charger20mV clamp for "dry circuit" testing
-
Product
Winding Resistance Tester
JYR-50C/40C/20C
-
1. With demagnetization function.2. Testing range reach to 20k3. Also apply to testing tranformer with high winding resistance.
-
Product
Wind Power Solution
EVO ACCIONA
-
The EVO ACCIONA is custom-made with firmware and fixtures designed specifically for Acciona turbines. These precisely designed fixtures make generator-to-gearbox alignment easy inside any nacelle – safeguarding reliability and optimizing the energy efficiency of the wind turbine.
-
Product
Wind Power Solution
ECO GE
-
The ECO GE is custom-made with firmware and fixtures designed specifically for GE 1.5x and 2.5x. These precisely designed fixtures make generator-to-gearbox alignment easy inside any nacelle – safeguarding reliability and optimizing the energy efficiency of the wind turbine.
-
Product
Low Resistance Ohmmeters
-
Some times know as Ducter testers, these are highly accurate, easy to operate instruments that measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 200 amps covering a multitude of applications that require precise low-resistance measurements.
-
Product
Wind Tunnel Balances
-
To meet the increasing demands of a modern wind tunnel and the need for appropriate simulation, HORIBA has developed the rolling road and wheel spinning units for road simulation. To increase the wind tunnel efficiency, the HORIBA wind tunnel balances can be equipped with lifting platforms which enable vehicle modifications to be performed in a short time
-
Product
Ultrasonic Wind System
UWS
-
Aeronautical & General Instruments Ltd.
Data from the mast-mounted (and virtually maintenance-free) anemometers is processed and used to drive full colour displays. The system calculates cross winds, head winds and tail winds, gusts and lulls and directional variation, as well as allowing for marked discontinuities. Instantaneous data may be displayed, as well as 2 minute and 10 minute averages. Systems can be supplied fully installed with comprehensive engineering and operator training, and post-installation support is available worldwide.
-
Product
Wind Speed Anemometers
-
Comptus A75-101 and A75-104 Wind Speed measurement anemometers are built with durable injection molded polycarbonate rotors and housings, and utilize a fully hardened beryllium copper shaft.
-
Product
Winding Resistance Tester
JYR20S/10S
-
DC winding resistance testing is regarded as another essential routine screening tool. It indicates problems such as loose, defective or incorrect connections, which cause enough transformer failures each year to be regarded as a failure category of its own.
-
Product
Offshore Wind Farm Testing Equipment
-
Potential readings taken by a diver holding a BathyCorrometer in contact with submerged steel structures can be analysed by engineers to determine whether the cathodic protection systems are working effectively or whether remedial action is required.
-
Product
Wind Meter Base Model
Kestrel 1000
-
The Kestrel 1000 Wind Meter is the base model in our extensive assortment of Kestrel pocket weather meters. Simple and compact, the Kestrel 1000 fits right into the palm of your hand and weighs a mere 65 grams. It's also extremely durable and totally waterproof, allowing you to measure wind speeds in even the harshest weather conditions. It even floats.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
Product
Bench-Mounted Ohmmeters
-
The range of our bench-mounted ohmmeters are ideally suited for laboratory testing of samples and production line testing.
-
Product
WINDING COIL TURNS TESTER
VE201R
-
Winding Turns Tester for Counting Measuring Number of Turns for Air Core Coils, Bobbin Coils or Solenoid Coils. Can Measure : Turns along with Winding Polarity and DC Resistance.Turns Measurement : 1 Turns to 80,000 Turns
-
Product
Transformer Winding Resistance Meter
10A
-
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
Product
Wind Turbine Condition Monitoring
-
It has also become increasingly apparent in recent years that the wind turbine industry has recognised the importance of condition-based monitoring, especially for offshore wind turbines, where access is often limited.To increase reliability and minimise down time, many wind turbine manufacturers, owners and operators are turning to condition-based monitoring systems, aimed at predicting wind turbine maintenance issues, so that operators can quickly and effectively carry out predictive maintenance, repairs and replacements of components when needed, without the need for costly routine maintenance checks and visits. As a result, a condition monitoring system increases operational time, improves site performance and reduces maintenance costs for wind turbines, especially offshore ones.
-
Product
Digital Micro Ohmmeter
-
*For fast and accurate measurements of low resistance on Switch Contacts, SF-6 Switch Gear, Bushbars, Splices, Joints, Fuses, Breaker Contacts, and Rail Bonds.*100A DC continuous current in 4 ranges of 10A, 20A, 50A and 100A*4 1/2 digit display for higher resolution*Wide resistance range of 20µΩ to 200mΩ in 5 ranges*Suitable for operation in energized switchyard conditions*SMPS based- lightweight and portable
-
Product
TRANSFORMER WINDING RESISTANCE METER
-
International Biological Laboratories
This Test set is suitable to measure winding resistance of transformers, single or 3-phase, star or delta connected upto several MVA.Two independent displays read the resistance of both primary & secondary windings simultaneously. However, primary or secondary winding can also be measured separately.