Process Calibrators
Assure process control signal validity.
-
Product
Process Trace Oxygen Analyzer
Model 3020T
-
Teledyne Analytical Instruments
The Model 3020T is a microprocessor-based instrument for detecting oxygen at the parts-per-million (ppm) level in a variety of gases. This instrument serves as the explosion-proof, bulkhead-mount version of the 3000 Series. Simple menu choices, externally accessible command switches, and dual LCD and LED displays make setup and operation clear and quick.
-
Product
Calibration Kit
WR-12
-
This precision calibration kit contains a flush short, offset piece and broadband load which allows for a full 12-term port calibration.
-
Product
Documenting Calibrators
-
We offer documenting calibrators, for us the “documenting” calibrator means a calibrator that can store the calibration results into its memory and upload them to calibration software. This benefits you as you don’t need to carry pen and paper and spend time in making notes and typing them into software.
-
Product
Process Thermal Conductivity Analyzer
CI-IN56
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
CI-IN56 thermal conductivity analyzer is a kind of intelligent analyzer based on microprocessor, considering microprocessor thermal conductivity sensor as measuring unit. It has high accuracy, good stability, comprehensive function and long service life. Applied to test the H2 or He in binary gas or binary mixture gas. - See more at: http://en.ci-ele.com/dcb675d2-4e33-4eb9-33a0-60edf78c9348/6b085f77-cb25-8ccc-faaf-9b581710d730.shtml#sthash.Xs2anvsw.dpuf
-
Product
Laser Calibration System, Superior Accuracy, Portability and Reliability
5530
-
The configurable system offers all the components you need to perform a variety of measurements using the USB on your PC as the host controller and power source. For basic linear measurements you will need the USB Axis Module, USB Sensor Hub, Air and Material Sensors, Sensor Cables, Software, Laser, Laser Cable, Remote Control (optional)and the Linear Optics Set. Other available options include the Laser Tripod (with laser mounting plate), optics and fixturing kits for making additional types of measurements, and wheeled transit cases.
-
Product
Infrared Calibration
-
Optical pyrometers can be calibrated from 800 to 2300C using NIST certified ribbon filament lamps and temperatures up to 3500C using a graphite arc furnace. Infrared thermometers can be calibrated from -30C to 2300C utilizing state-of-the-art blackbody sources and transfer standards.
-
Product
Electrical Test Calibrators
-
The electrical test calibrators from Time Electronics are designed for rapid calibration of various electrical test equipment. Portable calibrators include the InsCal models for insulation tester calibration and the PatCal for calibration of portable appliance testers.
-
Product
Vibration Transducers Calibration System
-
The system is used for calibration of vibration transducers as well as:*ICP and charge accelerometers;*piezoelectrical and capacitive vibration transducers;*vibration-measuring instruments.
-
Product
Blackbody Calibrators
-
Omega offers a diverse portfolio of blackbody calibrators used to calibrate infrared pyrometers. Blackbody calibrators use a high emissivity target plate or target cavity to minimize error.
-
Product
Calibration Wheel
-
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Calibration wheel is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
Product
Calibration and Verification Kits
-
Flann offers a wide range of calibration and verification kits to suit many applications and price points. Compatibility with the vast majority of current and legacy VNAs can be provided. Additionally full customisation of our kits is possible to suit your requirements.
-
Product
Inline Process Refractometers and Concentration Sensors
-
MISCO Inline Process Refractometers and IRIS Intelligent Concentration Sensors are SMART sensors. They allow you to continuously monitor and control the concentration of dissolved solids or water-soluble fluids. As a result, you will save time and money compared with manual sampling, while improving accuracy and efficiency. Inline Process Refractometers and IRIS sensors are ready to connect directly to a PLC, HMI, or other data capture system.
-
Product
Partial Discharge Pulse Calibrator
TPK
-
Partial discharge puls calibrator TPK is a battery-powered handheld device for determining the correction factor in a Partial Discharge test circuit and to verify the Partial Discharge measurement.
-
Product
Furnace Calibration
-
Tempsens Calibration Centre offers calibration of wide ranges of Furnaces at site and at our lab.
-
Product
Process Analyzers
202X Series – single-method process analyzers
-
Single-method process analyzers for water and wastewater monitoring with titration, pH, ISE, or photometry methods.
-
Product
Pharmaceutical Process Monitoring
-
Our pharmaceutical products target aseptic fill/finish manufacturing applications including manufacturing operations that utilize barrier isolators and lyophilization, often used to process the fastest growing segment of the pharmaceutical industry, biopharmaceuticals.
-
Product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
-
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
Product
Ralston Quick-test™ Microbore Calibration Hoses
-
Ralston Instruments Quick-test™ hoses can be attached and detached without a wrench or thread sealant while maintaining a working pressure of 6900 psi (475 bar). Quick-test hoses are small in diameter, flexible, and low in volume. These hoses provide an ideal way of transmitting pressure during a vacuum or pressure calibration. A wide variety of adaptors provide a connection for most calibration applications.
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Robot Calibration
-
Achieve improved absolute robot positioning accuracy via dynamic robot calibration using API’s Laser Tracker and Active Target a self-orienting motorized 360° rotation SMR.
-
Product
Process / Voltage / Current
-
Calibrator high precision process signals able to measure and generate current and voltage.
-
Product
Inline Process Refractometer – Smart, Rugged, Flexible
MVP™ Series
-
The MVP (“Most Valuable Process”) inline process refractometer is a rugged industrial refractometer equipped with MISCO’s latest SMART-sensor technology for automated continuous measurement of process fluids. This sensor is an industrial workhorse with wide operating temperature and pressure limits and a wide measurement range.
-
Product
CableEye Tester Calibration Verification Board | Cable & Harness Tester
CB50
-
Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently.
-
Product
Calibrators
-
Orbit Controls calibrators are suitable as signal sources for test benches or laboratories. They can be used as generators for calibrating and testing electronic measuring devices or assemblies, both by manufacturers and by companies that must perform periodic calibration tasks for quality certification.
-
Product
VME Radar Processing System
-
Signal Processor is Standard 19' rack mount chassis. 400 Hz, 3-phase, 115VAC aircraft power is available. Typical system can handle 200 MB/s (minimum) input data (also output data since we record the input data). Options include 10 GigE, Infiniband, FibreChannel or Serial FPDP. Optional 1GigEthernet for output products, parameter data, control messages, etc.
-
Product
Frequency Extension Calibration Kits
FEK
-
Farran’s FEK-xx-0001 calibration kit provides accurate calibration of the Vector Network Analyzer (VNA). It is compatible with TRL and SOLT calibration techniques and allows for a full 12-term port calibration.
-
Product
Calibrator for Vibration Transducers
HD2060
-
Hand-held calibrator for vibration chains with frequency 15.915 Hz and levels 1 m/s² and 0.1 g, and frequency 159.155 Hz and levels 10 m/s² and 1 g. With LCD display.
-
Product
Handheld Calibrators
-
These handheld calibrators are perfect for calibrating thermocouples and RTD's in cases where the sensors are fixed or need to be calibrated on the spot. Locations such as factory floor or in the lab.
-
Product
Calibration & Demag.
Model 8515-D
-
The Model 8515-D is a medium-energy, high voltage, and capacitor discharge type ringing demagnetizer capable of desaturating Ceramic and Rare Earth magnetic materials. The Model 8515-D is easily adapted to a wide range of production and laboratory demagnetizing requirements. A modern solid-state electronic control circuit, coupled with a rugged, heavy-duty discharge SCR and fixture, make this demagnetizer a highly reliable, low maintenance unit. The electronic voltage control circuit prevents the Model 8515-D from being discharged before the preset energy level has been reached, avoiding incomplete magnet desaturation. An easy to read front panel meter monitors the capacitor voltage. The energy storage level can be easily changed in the field. Integral electrical interlock and fail-safe circuitry provide a high degree of operator safety.





























