Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
16 Thermocouples/RTD Ch
APCI-3200-16
-
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel16 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 8 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
Product
Exhaust Gas Thermocouples
HYBRID Series
-
The AMETEK Hybrid Series Exhaust Gas Thermocouples for Frame 7 and 9 applications have been designed, fully tested and qualified to meet OEM specifications. AMETEK has worked closely with the OEM turbine manufacturer to qualify and engine test this thermocouple as a direct replacement, or for upgrading an older style Exhaust Gas Thermocouple.
-
Product
Fine Wire Versatile Thermocouples ANSI
-
An exposed junction thermocouple is the simplest form of thermocouple. It consists of two pieces of thermocouple wire joined together with a welded bead. Since they can be made very small, an exposed junction thermocouple can provide a very fast response time.
-
Product
Thermocouples
-
Watlow Electric Manufacturing Company
Thermocouples are best suited for high temperatures, extreme environments or applications requiring microscopic size sensors.
-
Product
Moulded On Thermocouples IEC
-
A moulded plug gives a robust construction as well as providing a waterproof termination.
-
Product
Exhaust Gas Thermocouples
8TR4C Series
-
The AMETEK 8TR4C Series Exhaust Gas Thermocouples for Frame 7 and 9 applications have been designed, fully tested, and qualified to meet OEM specifications. AMETEK has worked closely with the OEM turbine manufacturer to qualify and engine test this thermocouple as a direct replacement, or for upgrading older style Exhaust Gas Thermocouples.
-
Product
8 Inputs Temperature Data Logger – Thermocouples
HD32.8.8
-
Rugged data logger with 8 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes.
-
Product
J-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 2 m
745690-J002
Thermocouple Contact (ITA)
J-Type Thermocouple, 32°F to 900°F Temperature Sensor - The J-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the J-Type Thermocouple and acquire synchronized temperature data in units of degrees. The J-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Fabricated And Specialist Thermocouples
-
Fabricated and Specialist Thermocouples to suit a wide range of applications.
-
Product
K-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 1 m
745690-K001
Thermocouple Contact (ITA)
K-Type Thermocouple, 32°F to 900°F Temperature Sensor - The K-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the K-Type Thermocouple and acquire synchronized temperature data in units of degrees. The K-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
J-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 1 m
745690-J001
Thermocouple Contact (ITA)
J-Type Thermocouple, 32°F to 900°F Temperature Sensor - The J-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the J-Type Thermocouple and acquire synchronized temperature data in units of degrees. The J-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Balance Thermocouple Power Sensor, DC To 50 GHz
N8487S
Power Sensor
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
Product
K Thermocouple Penetration Probe
TP758
-
"K" Type thermocouple penetration probe. °C max: 400. Response time: 4 s.
-
Product
K Thermocouple Immersion Probe
TP742
-
Immersion “K” Type thermocouple probe. Tolerance according to IEC 60584-2 standard.
-
Product
MAX31855 K-Type Thermocouple Sensor Breakout
SEN-30001-K
-
Breakout board for the MAX31855K digital thermocouple interface IC. Measured temperature range is -270C-1372C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header, has a vertical mini thermocouple connector and four mounting holes for standoffs and 4-40 screws.
-
Product
Thermocouple (K-Type) And Temperature Probe Adapter
U1186A
-
Consists of a K-type thermocouple bead and a mini connector to dual banana plugs.
-
Product
K-Type Thermocouple
61-461
-
*Measures up to 275°*K-type thermocouple plugs into digital multimeter voltage jacks with 61-465 adapter
-
Product
Multi-functional High-speed I-V Measurement System
“Rakit”
-
Rakit is a maintenance device to measure current and voltage characteristics string by string, to grasp solar system characteristics, abnormal data, etc. The device comprising of I-V tracer, pyranometer, thermocouple, data logger, and "I-V data analyzer," the multi-functional analyzing software, provides accurate analysis report quickly. The I-V data analyzer is compatible with the following I-V tracers:
-
Product
K Thermocouple Surface Probe
TP745
-
Surface thermocouple Type “K” probe. Tolerance according to IEC 60584-2 standard.
-
Product
Low-Thermal EMF LXI Matrices
-
Pickering low-thermal EMF LXI matrices offer excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in automatic test equipment, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC microvolt measurements.
-
Product
Thermocouple Power Sensors
N8486AR
Power Sensor
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
LXI Low Thermal EMF Matrix 1-pole 14x33
60-510-004
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset. The 60-510 is designed in accordance with the LXI Standard 1.4 and is supplied in a 2U high, full rack width case with 500mm depth.
-
Product
Balance Thermocouple Power Sensor, DC To 18 GHz
N8481S
Power Sensor
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
Product
K Thermocouple Immersion Probe
TP741
-
Immersion "K" Type thermocouple probe. Stem diameter 1,5 mm.
-
Product
Thermocouple Contact, ITA, Copper, Type T (°C)
610113169
Thermocouple Contact (ITA)
Primary mating contact 610113168.
-
Product
PTO Dynamometers
-
AW is the world leader in AG/PTO dynamometers with over 14,000 units sold. AW's hydraulic activated load unit is water cooled allowing it to test high torque loads for continuous periods of time. AW's heavy duty load units are well known to last for decades. Combine this with all new computerized electronic load control, software, thermocouples, sensors and you have a system second to none - the AG.X Series.
-
Product
LXI Low Thermal EMF Matrix 1-pole 56x33
60-510-001
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Infrared Thermometers
-
Two specifications tell you nearly everything you need to know about any infrared (laser) thermometer: its measurement range and its distance-to-spot (D:S) ratio. The wider the range and the higher the D:S number (a measure of its optical resolution), the better the instrument. Infrared Thermometers (IRTs) with lower numbers are perfectly adequate for simple tasks like spot-checking food temperatures and energy auditing such as the IRT207 Non-Contact Infrared Thermometer. Higher-priced infrared thermometers intended for industrial users may have a SKU that ends in "K" such as the IRT850K Ultra-Wide-Range Infrared Thermometer with K Port and Adjustable Emissivity. The "K" indicates that it can accept inputs from a "K" type thermocouple probe used to measure temperature on-contact.





























