Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
Dataloggers
-
Data loggers with one or more signal channels for DC and AC voltages and currents, thermocouples, Pt thermometers, process signals and serial data interfaces RS232 / RS485 are designed for industrial use. They can also be used as monitors or process controllers with additional data and signal outputs for control purposes. The devices are designed for panel construction and have communication software for Windows applications.
-
Product
Shield
Arduino MKR Therm Shield
-
The MKR THERM Shield allows a board of the MKR family to acquire temperatures from a thermocouple of type K and a DS18Bxx digital one wire sensor. The Thermocouple is a kind of temperature sensor that offers high accuracy and a wide range of measured temperatures. Its analog nature requires specific interfacing and this shield relies on the MAX31855 thermocouple digital interface.
-
Product
Calibrators
-
Thermocouple temperature calibrator is capable of measuring and simulating up to 8 types of thermocouples (J, K, T, E, R, S, B, N), as well as a voltage in mV.
-
Product
PXI Isolated Millivolt Thermocouple Simulator - 24 Channel
41-761-002
Simulator
The 41-761-002 is a low voltage 24-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
Product
Two Inputs Thermocouple Thermometer
HD2328.0
-
Thermocouple thermometer for probes type K, J, T, E. It measures temperature by means of immersion, penetration, contact or aria probes. Two inputs for miniature thermocouple connectors. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree.
-
Product
Configurable System For Temperature Measurement With CAN Interface
MU thermocouple1 CAN
-
The thermocouple measuring unit offers connections for 8 thermocouples, which are designed for the temperature measuring ranges J, K or T, depending on the product version.
-
Product
Miniature Digital Panel Meter
CSMS-321
-
Measuring DCA, DCV, Temperature. 1/32 DIN Size ( 48mmX24mm ). Accuracy: +/- 0.1%(DC), +/- 1%(Thermocouple), +/- 0.2%(Pt100). 3 1/2 Digits Display: 1999. Input Max. 2Adc +/- 10%; 300Vdc, T/C type K: 1200J, Pt100:600J. Aux Power 5Vdc +/- 10%; Isolated Aux. Power 5Vdc, 12Vdc, 24Vdc available in option. Easy to wire, screw type terminal. Outside dimensions is 1/32 DIN Standard ( 48 x 24mm ). High stability & low cost.
-
Product
Thermocouple Power Sensors
N8481B
Power Sensor
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
Push-Button Temperature Transmitter
659
-
Series 659 Push-Button Temperature Transmitters accept thermocouple (J, K, T), RTD (Pt100Ω) or thermistor input and provide a linearized 4 to 20 mA output. The transmitter is quickly ranged and calibrated by using a single on-board switch
-
Product
Vacuum Measurement
-
Agilent's full range of active and passive vacuum gauges and gauge controllers from atmosphere to UHV/XHV allow you to precisely and reliably control and measure vacuum. We offer Thermocouple (TC), Bayard Alpert (BA), Pirani, Inverted Magnetron (IMG), and Hot Filament (HFIG) gauges. Our gauge controllers are compatible with both Agilent and competitors' gauges and can handle up to 12 channels. Agilent controllers come with several communication interfaces including Profibus, ethernet, and RS-232/485 (other interfaces may be available upon request). There is also the option of a portable gauge controller (HGC-536).
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
Locator Tool
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
Single Cell Hardware
-
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
Product
BNC-2120, 68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block
777960-01
Terminal Block
68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.
-
Product
MAX31855 T-Type Thermocouple Sensor Breakout
SEN-30001-T
-
Breakout board for the MAX31855T digital thermocouple interface IC. Measured temperature range is -270C-400C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header, has a vertical mini thermocouple connector and four mounting holes for standoffs and 4-40 screws.
-
Product
Condition Monitoring
-
m+p Coda is a versatile monitoring system that captures and records signals coming from sensors such as accelerometers, thermocouples, strain gauges, and pressure transducers. Limit checking and alarm monitoring is provided for every active channel. The active channels are clearly displayed in a separate window, out-of-limit data can be seen at a glance. Alarm events are entered into a log file and can be reviewed at any time. You have the option to change the alarm limits online at any time without stopping the data acquisition.
-
Product
Head-Mount Temperature Transmitters
-
The compact head mounted temperature transmitter type from ABB is designed for standard type B sensor heads. The advantage increased measuring accuracy resulting from conversion of the sensor signal into a stable output signal close to the sensor. When using thermocouples, no compensating cables are therefore required.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745690-T002
-
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Gauge Type T Thermocouple Wire
W-TW-24
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Thermocouple Thermometer – 2 Inputs
HD2128.1
-
Thermocouple thermometer for probes type K, J, T, R, N, S, B, E, two inputs.
-
Product
PXIe-4353, 32-Channel, 24-Bit PXI Temperature Input Module
781348-01
Analog Input Module
32-Channel, 24-Bit PXI Temperature Input Module—The PXIe‑4353 is a thermocouple input module that provides integrated data acquisition and signal conditioning for temperature measurements. The PXIe‑4353 includes increased accuracy and synchronization features for scalable measurement systems from low‑ to high‑channel counts. The high accuracy is attributed to the NI TB‑4353 isothermal terminal block that optimizes thermal conductivity between the thermocouple terminals and the cold-junction compensation (CJC) channels. The PXIe‑4353 has two auto zero channels for offset compensation as well as open thermocouple detection to identify disconnected thermocouples.
-
Product
Thermocouple Data Logger
IM2000 Series
-
We have been offering IM2000 Series Thermocouple Data Logger with direct interfaces for various types like J / K / R / S / T / B / E etc. Loggers have built in ambient compensation. The thermocouples are most commonly used sensors for measuring temperature in process industries. These can take any form and are available in various mechanical shapes. The temperature ranges are varied.
-
Product
Portable Temperature Monitor
PTM1
-
The Model PTM1 is a high performance, precision hand-held instrument for the measurement of temperature using Physitemp’s Type T (copper-constantan) thermocouples (will also accept J & K). This versatile instrument measures temperature in both °C and °F. The internal memory of the microcomputer stores the minimum and maximum measured temperature range for instant recall via the LCD display.
-
Product
DC Source/Calibrators
-
Our DC Source/Calibrators are designed for a typical applications such as the design, check and calibration of high speed, high resolution A/D converters; design and certification of high speed data logging and process control systems; calibration of digital voltmeters and multimeters; as an “IMBEDDED STANDARD” and/or simulator; design, testing, simulation and certification of thermocouples, strain gages and transducer instrumentation.
-
Product
PTO Dynamometers
-
AW is the world leader in AG/PTO dynamometers with over 14,000 units sold. AW's hydraulic activated load unit is water cooled allowing it to test high torque loads for continuous periods of time. AW's heavy duty load units are well known to last for decades. Combine this with all new computerized electronic load control, software, thermocouples, sensors and you have a system second to none - the AG.X Series.
-
Product
In-Line IR Sensor
ILA
-
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
Product
Temperature Calibrators
-
Ensuring process temperature accuracy involves calibrating not only the system’s electronic temperature signals, but also the very temperature sensors that initiate those signals. Rugged Fluke handheld temperature calibrators source and measure RTDs and thermocouples, power transmitters, and store data. Fluke Calibration temperature sources cover temperatures from -45 °C to 1200 °C and include handheld, portable, and benchtop calibrators. Infrared thermometer calibrators and reference measurement thermometers ensure every necessary tool is available to you.
-
Product
Transmitters
-
Transmitters are used for industrial applications to convert process signals into standardized isolated output signals 0-10V or 0 / 4-20mA. In addition to the process signals, various sensors can also be connected, e.g. Pt-100, thermocouples, potentiometric sensors, inductive, capacitive and optical initiators, resistors, etc. The transmitters are supplied with 230VAC or 24VDC and housed in a DIN housing for 35mm rail mounting.
-
Product
Infrared Thermometer
DITH 120
-
Infrared Thermometer is also known as laser thermometerInfrared thermometer is a thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.Laser is used to help aim the thermometer or non-contact thermometers or temperature guns, to describe the device's ability to measure temperature from a distance. By knowing the amount of infrared energy emitted by the object and its emissivity, the object's temperature can often be determined. Infrared thermometers are a subset of devices known as "thermal radiation thermometers".The design essentially consists of a lens to focus the infrared thermal radiation on to a detector, which converts the radiant power to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature. This permits temperature measurement from a distance without contact with the object to be measured. A non-contact infrared thermometer is useful for measuring temperature under circumstances where thermocouples or other probe-type sensors cannot be used or do not produce accurate data for a variety of reasons.
-
Product
LXI Low Thermal EMF Matrix 1-pole 42x33
60-510-002
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.





























