Partial Discharge
voltage discharge within an insulator causing dielectric breakdown.
See Also: Partial Discharge Detection, Partial Discharge Monitors, PD, PD Test, Partial Discharge Test
-
Product
Tan Delta Measurement
TD Series
-
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
Product
Software
-
The MSPS Software offers complete remote control of the partial discharge test set TPP.It is built ontop of a powerful database and offers the following possibilities. It is especially designed for use in a continious manufacturing test environment within a quality management system.
-
Product
Online PD Spot Tester
Liona
-
Cable testing and diagnostics with the BAUR liona. Liona is a portable online PD spot tester for measuring and locating partial discharges in cables and switchgear during normal mains operation. Liona lets you test cable systems and electrical equipment online without switching off partial discharge activities, and then generate trend analyses. Even a PD spot test (duration: 5-10 minutes) is capable of reliably assessing the current status of your system.* Automatic PD detection during normal mains operation (without switching off the cable route)* With DeCIFer technology: PD identification based on 500 million measurement results* Precise online PD mapping with PD transponder
-
Product
Partial Discharge Measurement System
DAC-6021
-
DAC-6021 is a measurement system for testing Partial Discharge of high frequency equipment, power devices, stator coils, etc.Since the system combines Partial Discharge Measuring Instrument (DAC-PD-3) with Testing Corona-free Variable Frequency Voltage Source (DAC-WT-50) and Testing Shielded Chamber, most external noises are removed, and the measurement is safe.
-
Product
Horn Antenna
-
Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.
-
Product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
-
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
Product
Partial Discharge Tester
19501-K
-
Chroma Systems Solutions, Inc.
The Chroma 19501-K Partial Discharge Tester is an instrument equipped with AC hipot test and partial discharge detection functions, providing 0.1kV~10kV of AC output, 0.01μA~ 300μA of leakage current, and 1pC~2000pC partial discharge detect ion range for measurement. Chroma 19501-K Partial Discharge Tester is compliant to the IEC60270-1 standard in particular the partial discharge testing requirements for high voltage.
-
Product
Spiral Antenna UHF Trafo
-
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes Spiral antenna the optimal sensor for direct installation on high voltage Transformers. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces. Contact our sales department for consulting.
-
Product
Multi-Channel PD System Locator
PDiagnostic Series
-
Power Monitoring and Diagnostic Technology Ltd.
The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.
-
Product
Partial Discharge
-
Partial discharge (PD) is a local electrical discharge that occurs in imperfections or inhomogeneities. The partial discharge measurement is a so-called “non destructive test” to determine the quality of insulating materials. On the contrary of pure high-voltage test, th test item is not pre-damaged at low PD levels.
-
Product
PD Monitoring systems
TECHIMP PD Hub™
-
Techimp’s Partial Discharge (PD) Monitoring systems usually consists of a Central Unit and distributed Data Acquisition Units – the PD Hub™ - able to acquire and process the PD signals locally detected through PD sensors installed on each of main electrical assets (generator, transformer, HV cables and GIS).
-
Product
Partial Discharge Test Set
-
We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.
-
Product
Dielectric Loss Tangent Testing Instruments
-
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
Product
Acoustic Imaging Cameras
Si1 and Si2 Camera series
-
Helps you significantly lower costs associated with mechanical bearing issues and partial discharge on electrical equipment. It also enables you to drastically reduce leaks in your facilities, cutting down expenses related to compressed air and gas leaks.
-
Product
Cable Diagnostic Tools
-
For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.
-
Product
Battery Cell Insulation Tester
Chroma 11210
-
Chroma Systems Solutions, Inc.
Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.
-
Product
Electrical Safety Testers
-
A high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
PDIV Tester for EV Motor
PDIV 500-T
-
Shanghai Dean Electrical Co., Ltd
Differing from partial discharge with high frequency pulse which produce sound and light phenomenon, the power frequency AC voltage reaches a certain threshold, can only produce instantaneous current leakage around the tested sample, it can be detected through discharge capacity (unit: PC) to evaluate partial discharge phenomena..The instrument PDIV 500-T is designed to put samples such as enameled wire, insulation paper/film, and electric motor stator in the High temperature / humidity environment chamber, applying a power frequency voltage with a programed rising speed, and prefect ground connection must be guaranteed , through the coupling capacitor as the medium, the continuous detection of discharge capacity against the voltages will create formulation between the Voltages and discharge capacities (pc), the software will find the discharge voltage threshold called PDIV.
-
Product
Partial Discharge Measuring Equipment
-
Different from a conventional partial dischargemeasuring set provided with a fixed testingfrequency, Model DAC-PD-5 is newly designed toselect the center and the bandwidth of testingfrequencies so that partial discharges emitting in anoptional frequency in the range of a specifiedbandwidth can be detected. Generally, partialdischarges are measured in a wide band frequencythough; the detecting sensitivity must be lowered inorder to detect partial discharges partially.DAC-PD-5 has a wider bandwidth and can measurepartial discharges in a high sensitivity by bypassingnoises emitting bands.
-
Product
Portable GIS Partial Discharge Detector
JHPD-10
-
Xiamen Jiahua Electrical Technology Co.,Ltd
JHPD-10 quickly and accurately detects various kinds of partial discharge signals that occur with insulation defects in GIS. Attached on the surface of GIS the detector collects the inside discharge signal of impure gas, suspension potential and solid insulation material. The diagnostic software analyzes the fault character and locates the fault to avoid electricity accident. The device is for daily patrol inspection with high efficiency and easy operation features. Designed with two UHF signal channels, one detects the partial discharge signal; another excludes the disturbance signal like corona discharge in the air and mobile phone communication.
-
Product
Universal Partial Discharge Measurement and Analysis System
MPD 800
-
Our MPD 800 universal partial discharge (PD) measurement and analysis system represents the next generation of our widely-used and innovative MPD PD testing technology. Enhanced and newly-added hardware and software features ensure highly-sensitive multi-channel PD measurements for reliable, industry-standard PD testing on a variety of electrical equipment and components.
-
Product
Flexible Magnetic Coupler
FMC
-
The FMC (Flexible Magnetic Coupler) is a partial discharge sensor whose working principle is based on a direct magnetic coupling with the cable conductor and shield.It picks up a magnetic signal given by PD activity. His compact and robust design makes the FMC the optimal sensor for direct installation on cables and accessories such as joints and termination.This sensor has a sensitive side which has to face to the object under test, while the other side (shielded) reject the noise from the environment.
-
Product
Handheld PD Tester
-
Weshine Electric Manufacturing Co., Ltd
TEV partial discharge inspection instrument uses two emerging technologies, transient-to-ground voltage (TEV) measurement and ultrasonic (US) measurement, to detect faults in switchgear. The equipment is portable and easy to operate. The TEV sensor is attached to the wall of the box, and the US sensor scans and detects along the gap on the switch cabinet.
-
Product
Partial discharge measurement with remote wireless reading
PD-LT
-
The PD-LT allows online partial discharge detection on cable accessories such as cable head for safety and maintenance purposes.The PD-LT indicates the intensity of the partial discharges, converting the electrical charge units (pC) into decibels (dB). Thus the reading is kept as a simple intensity level indication, proportional to the probability of a fault's presence in the tested medium voltage accessory.The remote display gives a dB value of the probe's measurement. The dB value will vary along with the discharges indicators on the PD-LT probe. The measurement range is from 0 to 65dB and the display will show ''OL'' if the reading is over 65dB.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Partial Discharge Test System
TPP
-
The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).
-
Product
Compact Ultrasonic Testing Device
SONAPHONE® Pocket
-
With the SONAPHONE Pocket you identify problems even before they arise and create value at all levels of your company. Just by detecting and eliminating leaks you can reduce the energy costs for your compressed air system up to 30 percent. This also has positive effects on your operational safety and system productivity through early warning of bearing failure and evidence of partial electrical discharges.
-
Product
Automation
-
The Transformers and measurement capacitors used in high voltage and Partial Discharge test equipment are typically reliable over several decades of continious use. The control technology is however typically obsolete after only 10-15years. MPS offers automated , state-of-the-art High Voltage Testing Equipment with the following features.
-
Product
Acoustic Imaging
-
Acoustic imaging offers cutting-edge solutions for precise leak detection, partial discharge identification, and mechanical fault diagnosis. With high-performance microphone arrays and advanced algorithms, our products ensure exceptional industrial safety and perfomance.
-
Product
UHF PD Detector
-
Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.