Current Transformers
transfers accurately proportional levels of current to multiple circuits.
-
Product
Current Measurements of PWM or Inverter, AC/DC 0.5~5A, φ16mm
CTF-5DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 0.5~5A*Current measurements for PWM or inverter
-
Product
Eddy Current Probes and Drivers
-
Proximity sensors work on the eddy current principle. A proximity system consists of an eddy current probe, extension cable and driver. A high-frequency RF signal is generated by the driver, sent through the extension and probe cables and radiated from the probe tip. The tip consists of a precision wound copper coil inside a chemical and temperature resistant PEEK case.
-
Product
Low Level DC Current Data Logger
Process101A
-
The Process101A is one of MadgeTech's newest data loggers. It is part of a new series of low cost, state-of-the-art data logging devices. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers in the world today.
-
Product
Current Measurements of PWM or Inverter, AC/DC 1~50A, φ16mm
CTF-50DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 1~50A*Current measurements for PWM or inverter
-
Product
Voltage And Current Amplifier
KINGSINE KA30 / KA60
-
KINGSINE Electric Automation Co., Ltd.
KINGSINE's KA30 / KA60 voltage and current amplifier is high accuracy, high power, Panel-mounted type real time simulation power amplifier with four-phase voltage and three-phase current.
-
Product
Resistors for Calibration of Current Measuring Systems and Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
Is designed and made according to the Standard JB/T8225-1999 for DC resistors used in laboratory and electrical engineering.By using full closed structure and automatictemperature control it ensures resistor good long-term stability and small temperaturecoefficient. This DC resistor is very suitablefor DC current measurement and calibration of current measuring systems and current sensors. The maximal measuring current is 100A with measuring accuracy of ±0.02%
-
Product
Mini AC Leakage Current Clamp Tester
M-100+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・18mmφCT window and ultra compact size.・Least affection from the external magnetic field.・The special alloy is used for core material that resists the rust over long period of use and ensures stable,high accurate measurements with very slight influence from aging.
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-40
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Compact size*AC 1A~600A*Current measurements of feeder
-
Product
Current Meter
Model 106
-
The Model 106 is the ideal instrument for coastal and estuarine applications and other light-duty survey work.
-
Product
Low Input Bias Current Amplifiers (<100 pA)
-
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Portable Three-Phase Current Load
EE-120A-3
-
The Current Source is able to generate three-phase currents, synchronized with the service voltage, with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current is individually adjustable. The values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
Product
High Current SMU 600/1200/2400 A
AXC85xx
-
Generate extremely short, fully regulated current pulses in 4 ranges. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.
-
Product
Split type Pulse Current Sensor
CTF-05T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For detecting current pulse with open collector output (for power pulse)
-
Product
Current / Voltage input Panel meter with output options
DM3420
-
The DM3420 panel meter accepts Voltage and Current process signals and displays the process value on a high efficiency daylight readable LED display. A built in transmitter power supply is also provided.
-
Product
Iron Core Current Limiting Reactors
-
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
Product
Transformer Winding Resistance Tester
KRI 9310
-
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
Product
Split Type AC Current Sensor
CTF-24
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For AC current and power measurements.*Wide measuring range (AC 0.1~200A).*Compliant with RoHS drective.
-
Product
Leakage Current Clamp Tester with Bluetooth
M-1141XR
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Waveform display is possible with connection to a smartphone・Measurement data is to be accumulated in the server, and it is available for graph and CSV output・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency (fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight
-
Product
Medical Leakage Current Tester
2675Y
-
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.
-
Product
High DC Primary Current Injection Test Set
PDC15k
-
PDC15k High DC Primary Current Injection Test Set adopts high-frequency invert principle to realize the high DC current output capability, with very small size and light weight. PDC15k is modular designed with changeable modules and multi-functions local control software.
-
Product
Epoxy Resin Silicon Rubber Outdoor Voltage Transformer
JDZW-10RG
-
Beijing GFUVE Electronics Co.,Ltd.
Outdoor voltage transformer of the type JDZW-10 is single phase and epoxy resin silicon rubber insulated product, it's used for metering electric energy, voltage control and relay protection in 50/60HZ rated voltage less than 12kV electric system. It can be used for medial voltage AIS, or can be used for medial voltage switchgears. They can operate in all kinds of environments (such as wide range temperature (-50~70℃), high altitude, high humidity, high pollution or salt). This model JDZW-10 outdoor voltage transformer is also as voltage source to supply 220V voltage.
-
Product
KVS Rugged Igniter Tester With Current Monitor
4314
Tester
The Valhalla Scientific Model 4314 KVS Digital Igniter Tester is designed to provide extremely safe and reliable resistance testing of explosive or volatile devices. Proven uses include fuses, squibs, igniters, explosive bolts, automobile airbag initiators and many others.
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 5~100A, Φ16mm
CTF-100DC-U48V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 5~100A*For current measurements for PWM or inverter
-
Product
8-Ch SPST 20A-250VAC High Current
YAV90087
Relay
8 power relays Switching 20A 250Vac PNP Outputs para control or YAV90304 control CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
Current Data Logger 0-24mA
VA601-A125
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multi-function record meter is a new record meter designed for the actual demand of various industrial site, which integr.
-
Product
NI-9265, 4-Channel C Series Current Output Module
779334-01
Current Output Module
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
Current Probe
DCP-BTA
-
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Product
Current Clamp Meter
CP 41
-
The CP 41 current clamp meter has been designed for reliable and accurate, non-intrusive measurement of AC, DC and complex waveform currents. Using advanced Hall Effect technology the CP 41 can measure currents accurately from 5mA to 40Amps.
-
Product
Fourier Transform Optical Spectrum Analyzer, 350 - 1100 nm
OSA201C
-
Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.





























