-
Product
Low frequency Amplifiers
-
Low-frequency amplifiersCurrent sourcesSystems with multiple amplifiersCustomized systems
-
Product
Ultra-Low Frequency Workstation
MK52 Series
-
Providing Ultra-Low Frequency levels, the MK52 Series offers the ultimate low natural frequency performance for a wide range of high resolution instruments, such as analytical balances, cell injection, confocal microscopes, patch clamping, optical microscopes, wafer probing, sensor calibration, atomic force microscopes and other sensitive equipment requiring high isolation efficiency.
-
Product
Very Low Frequency Control Element
VLFC
-
Think extremely low. With a range of 13-30 Hz—the lowest reach of any Meyer Sound speaker—the VLFC extends below the threshold of human hearing to let your audience feel the sound like never before.
-
Product
Neodymium Low Frequency Transducers
-
High energy neodymium magnetic designs, complex cooling systems and new technologies for high-power handling, minimal distortion and low weight.
-
Product
Low Frequency Active Antenna And Amplifier
Type NLF-2
-
A Hot, Active, Noise Reducing Antenna System that will sit on your desk and copy 2200, 1700, and 600 through 160 Meter Experimental and Amateur Radio Signals!
-
Product
Low Frequency 3-Way Power Dividers To 1500 MHz
-
Pulsar Microwave manufactures 3-way power dividers from 1 MHz to 1.5 GHz in both surface mount and connectorized packages. They are rated for an input power of 1 watt maximum for a load VSWR of 1.20:1 or better. This series of 3-way power dividers are currently offered in four outline packages. The hermetically sealed outline 301 and surface mount outline B are useful in portable applications where space is premium. Outlines 412 and 433 are connectorized versions in cross or in-line format, respectively.
-
Product
LXI Low-Frequency Matrices
-
Our LXI low-frequency matrices provide complete flexibility for connecting test equipment and the unit under test (UUT)together and are compliant with LXI Standard 1.4
-
Product
Broadband Marine Source
TPS™
-
TPS™ (Tuned Pulsed Source) is a new marine seismic source that provides geophysical clarity by improving low frequency (content while) also supporting important environmental benefits.
-
Product
Measurement System for ESD Protection
SampleProtect
-
The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.
-
Product
VLF/DC Hipot Cable Testing
-
From the outset, HV Diagnostics has been a pioneer in the development of a small, portable, single piece oil free VLF (Very Low Frequency) Hipot cable test instrument that would be reliable, user friendly and more technically advanced than anything available in the industry.
-
Product
E-Series Average Power Sensor
E9304A
Power Sensor
Refer to the E9301A for standard power sensor features Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies Special option available to 18 GHz Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
GEOPHYSICS, SEISMIC, and ATMOSPHERICS RESEARCH RECEIVER
Type RAS-1
-
Called the RAS-1, the receiver is designed for ultra low and very low frequency scientific research work, including the exploration of low frequency emissions due to seismic and earth-quake activity, study of atmospheric phenomenon such as "whistlers", and low frequency Sudden Ionospheric Disturbance (SID) and electromagnetics phenomenon. The RAS-1 will receive signals from under 200 Hz. To over 250 KHz in both narrow bandwidth modes as well as broad badnwidth reception.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Field Intensity Tester
Model KM 828
-
Kusam Electrical Industries Limited
The meter can inspect particular objects or devices radiating low frequency electromagnetic waves. It can be used for power wire, computer monitor, TV, audio and visual, electromagnetic oven or analogous electrical installation.
-
Product
HiPot Tester
HiPot-30
-
The SURETECH HiPot 30 tester provides an economical solution to Low frequency AC and DC testing of cables,terminations, motors, generators and other electrical apparatus. 0 – 30kV
-
Product
KPG 24kV VLF Test Set
-
Kilovolt Prueftechnik Chemnitz GmbH
The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.
-
Product
Passive Probes
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Test Board For QSFP+ Transceiver
EQSFP10
-
The OPTELLENT EQSFP10 is a cost-effective and convenient test board for testing QSFP/QSFP+ optical transceivers in R&D and manufacturing environments. The EQSFP10 is equipped with high quality RF connectors for data signals and test points for low frequency control and status signals. The EQSFP10 is equipped with power supplies to enable voltage margining. Key status signals are displayed using LED indicators.
-
Product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
RFID
LF (BIS C)
-
BIS C works with low frequency (LF) and uses two frequencies: 455 kHz for writing and 70 kHz for reading. The wide variety of passive data carriers with various dimensions, configurations, memory sizes, operating temperatures, materials, mounting options and ranges allows you to tackle nearly any technical task. BIS C established as the standard for tool identification.
-
Product
Blocking Capacitor, 0.045 to 26.5 GHz
11742A
DC Block
The Keysight 11742A blocking capacitor blocks dc signals below 45 MHz and passes signals up to 26.5 GHz. Ideal for use with high-frequency oscilloscopes or in biased microwave circuits, the Keysight 11742A will suppress low frequency signals that can damage expensive measuring equipment or affect the accuracy of your RF and microwave measurements.
-
Product
Ferrite Low Frequency Transducers
-
Ceramic magnetic design able to provide high-power handling and low distortion for the most demanding speaker manufacturers.
-
Product
AC Current Sensor
LFR
-
The LFR ac current probe has been designed to have market leading low frequency performance, meaning low phase shift and low noise. This compact, low cost, clip-around probe is both flexible and dual-range, and is optimized to give minimal phase measurement error at frequencies from 45Hz to 20kHz and have a very low noise floor.
-
Product
High-performance multifunctional AC Power Supplies (CV/CF)
PCR-LE Series
-
The PCR-LE Series is a new line of advanced multifunctional AC power supply that has been developed from our PCR-L/LA Series (linear amplifier type). The PCR-LE Series provides high reliability and can be applied to various applications, by taking advantage of the features that can control broadband waveform freely. Moreover, the PCR-LE Series can be configured as a core device of a test system combined with E-loads and Power Analyzers for “Grid Connection Testing” in regard to dispersed power generation, such as Solar Power, Wind Power, Fuel Cell, and Gas Engine referred to as “New Energy Field”. With various options, the low frequency immunity test and various power enviroment tests are supported. The options for parallel operation and three-phase operation enable you to expand a single-phase system up-to 27kVA, single-phase three wires up-to 54kVA, and a three-phase system up to 81kVA. The system can be applied to a large-scale EMC site for testing of industrial high-capacity air conditioners.
-
Product
VXIbus Module
-
Universal Switching Corporation
The VXIbus modules offered by Universal Switching Corporation are listed in the table below by "maximum" frequency range order beginning with low frequency (DC) to the highest (40GHz) followed by our soon to be released fiber optic modules. Each module has its own characteristics and features.
-
Product
Low Frequency RF Broadband Power Sources
-
Class A has RF power source, ideal for Industrial /Scientific / Medical applications. Class AS is a robust source of RF power for ultrasonic, laser modulation, RFI/EMI, plasma generation, general laboratory and industrial applications.
-
Product
RF Proximity Detector
Type RPD-2 AND Type RPD-2A
-
The Type RPD-2 Radio Frequency (RF) Proximity Detector is designed to detect and locate devices that radiate radio waves in the high frequency to low microwave frequency range. Such devices often include surveillance and “spy” equipment. The Type RPD-2, when used with the different sensors, will detect the emanation of the radio wave within a confined area, and then isolate its location to within approximately a square foot. The type RPD-2A may be used as an RF field strength indicator for antenna field strength measurements. The RPD-2A is identical in function except that the meter scale is calibrated in relative dB units.
-
Product
Triaxial Linear Accelerometers
-
Columbia Research Laboratories
The Triaxial Force Balance Linear Accelerometers range from general purpose, low cost sensors, capable of measuring DC and low frequency acceleration simultaneously in three axes, to Miniature Airborne, Highly Reliable Sensors that operate from +24 to +32VDC Aircraft power. Also offered are compact, premium performance, extremely rugged sensors, well suited for demanding missile and airborne applications.
-
Product
Electromagnetic Radiation Analyzer
SEM-600
-
Beijing KeHuan Century EMC Technology Co,.LTD
Broadband Electromagnetic Radiation Analyzer SEM-600 can accurately measure various complex electromagnetic environments. The probe covers all frequencies from low frequency to microwave radiation. It can measure electric field strength and magnetic field by equipping different types of probes. Intensity (magnetic induction) and power density, it is also equipped with ordinary probes and other weighted probes based on human safety standards.





























