Product
Dual-ridge Horn Antenna 1 to 18 GHz
EH118
-
EH118, a dual-ridge horn antenna that will operate from 1 to 18 GHz. This antenna has a balanced, smooth antenna factor curve that extends all the way to 18 GHz, a reduction of higher order modes on the aperture, and low return loss (SVSWR). The EH118 is applicable for commercial, military and automotive test standards and will include applicable calibrations. The EMC dual-ridge horn antenna offers these key features: single linear polarization, smooth/balanced gain with frequency, low return loss /VSWR, and ultrawide bandwidth (18:1).
-
Product
Electrodynamic Vibration Generator System
LVD-100KG
-
• Vibration table size: 500*500mm (Other size can be designed) • Vibration: 0~5mm (Adjustable range P-P). Vibration waveform: sine wave (half wave and full wave). Acceleration speed: 0~20g (Adjustable) • Maximum test load Capacity: 100kg • Accuracy: Frequency can be displayed to 0.01 Hz. Precision 0.1 Hz. • Sweep Frequency function (1~600Hz): (Upper frequency, Lower frequency, Time range) It can set real standard arbitrarily to sweep frequency back and forth • Programmable Function (1~600Hz): It can set each segment in 15 segments arbitrarily (frequency/amplitude/time/acceleration), and it can be recycled • Frequency doubling function (1~600Hz): 15 segments multiplied-increase: 1)Low to high frequency 2)High to low frequency 3)Low to high and then to low frequency, it can be recycled • Logarithmic function (1~600Hz), 3 modes of logarithm/can be recycled: 1)Lower to upper frequency 2)Upper to lower frequency 3)Lower to upper and then to lower frequency • Measuring instrument: To display amplitude, acceleration speed and the maximum acceleration speed.
-
Product
Acoustic Transducer
RESON TC 1037
-
Originally designed for underwater telephone systems, the TC 1037 is a rugged directional transducer ideal for operating at low frequencies.
-
Product
Phase Locked Oscillators
-
Phase locked oscillators (PLO) utilize state-of-the-art planar circuits, three-terminal devices and dielectric resonator technology to generate high-quality microwave signals at lower frequencies. Frequency multipliers, amplifiers and filters are used to extend the low frequencies for higher frequency requirements. The standard offering covers the frequency range of 2 to 110 GHz and provides both internal and external reference options. The frequency stability and phase noise are dependent on the oscillator reference type.
-
Product
Analog Seismic Sensors
Seismometers
-
Designed to yield the performance needed for scientific studies, our seismometers are used for monitoring long period (very low frequency) signals. These units are often used for earthquake monitoring and for triggering potential alerts during natural disasters such as tsunamis.
-
Product
Power Monitor, AC-Powered, Field Adjustable
YMA/YQA
Power Monitor
NAI's YMA and YQA Power Monitors are used to monitor voltage, frequency, and phase characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within predetermined limits.High and low voltage and frequency limits, and "pick-up" and "drop-out" time delay are field-adjustable using potentiometers. These power monitors are ideally suited for rugged defense and industrial applications.
-
Product
Frequency Counters
-
-Frequency Range : 0.2Hz to 5.5GHz Built-in CMOS Gate Array Fast, High-Resolution, 10 Digits Green LED Display Microprocessor Controlled Reciprocal Technique for Low Frequency Resolution Self Diagnosis Routine Total, RPM Function, Period Low Pass Filter(100KHz, -3dB) Rs-232c Interface(Option)
-
Product
Miniature Subwoofer
MM-10
-
Delivering expanded low frequency for applications that require excellent audio quality from a compact system, the MM-10 subwoofer allows system designers to create full-range systems where space limitations are a concern, and are adaptable to complement MM‑4XP and UP-4XP loudspeakers.
-
Product
Personal RF Detection Meters, Low Frequency
-
Personal RF Detection Meters, Low Frequency by Sensory Perspective Ltd.
-
Product
Sub-Harmonic Mixers
-
Subharmonic mixers are composed of a passive mixer with a subharmonically pumped (×2) local oscillator. These mixers allow designers to use low LO frequency, which eases the need to generate a high frequency LO signal. For high frequency application design, Analog Devices subharmonic mixers offer a simpler alternative to traditional mixers with no LO multiplier.
-
Product
Carbon-Fiber Reinforced-Polymer Optical Breadboards And Benches
-
Advanced Photonic Sciences LLC
Carbon fiber optical breadboards provide a similar thermal stability to Super Invar but at a lower cost and are inherently non-magnetic. For ages, steel breadboards have been the only choice; however, structures made from carbon fiber reinforced polymer (CFRP) have been used in the aerospace and space industries for many years due to their low weight, high strength, excellent thermal stability and low resonant frequencies. APS now brings this advanced technology to the world of photonics in the United States and Canada with carbon fiber breadboards from CarbonVision. Four grades of carbon fiber breadboard are offered: the economic EC-Series, the advanced AD-Series, the all-carbon AC-Series, and the slim SL-Series.
-
Product
XCITE 1200-2 Inertial Mass Excitation System
-
The Xcite 1200-2 Inertial Mass Excitation system provides a new dimension to structural testing. The ES-302 Exciter contains a 250 lb mass which is accelerated through a 2″ displacement by a hydraulic actuator. The 2,000 lb inertial force which is generated provides ample input to structures such as those shown below to perform low frequency seismic studies and high frequency rotating equipment analyses.
-
Product
Low Frequency RF Broadband Power Sources
-
Class A has RF power source, ideal for Industrial /Scientific / Medical applications. Class AS is a robust source of RF power for ultrasonic, laser modulation, RFI/EMI, plasma generation, general laboratory and industrial applications.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Turned Log Peri Antenna
MOLP80-1000M
-
This is Antenna for IEC61000-4-3 Radiation Immunity Test. Unique Structure with turned Element increase the GAIN at the low frequency. Stew structure of 22 and can be fitted to normal Antenna MAST.
-
Product
XCITE 1100 Laboratory Series
-
The Xcite 1100 Laboratory Series is the most popular of the Xcite product line because of its large force capacity and broad frequency range compared to its extremely compact size. The 5 GPM 3-Phase hydraulic power supply used in the system provides a high level of low frequency displacement response for testing system subassemblies and non-linear structures such as suspensions and elastomeric dampers. The small piston area of the exciter and the high performance servovalve combine to provide excitation to over 1000 Hz allowing structure borne noise path evaluations.
-
Product
The Leading Measurement System for the Analysis of Porous Materials
ELWIS
-
ELWIS (Evaluation of Light Weight Impedance System) offers a full and rapid characterization of porous materials based on the analysis of a single sample. The ELWIS system consists of the ELWIS-A and ELWIS-S components which can be used independently from each other although both applications are needed for a complete material simulation.ELWIS-A measures acoustic parameters that are needed to evaluate the acoustic performance of sound insulation and sound-absorbing multi-layer materials. An additional impedance tube for absorption measurements at higher frequencies is available for ELWIS-A.ELWIS-S measures structural parameters that are needed to simulate the dynamic and acoustic behavior of sound packages in the medium to low frequency range (including the "Poisson Ratio" for foam materials).ELWIS is very easy to operate: Thanks to its user-friendly software, the system can also be used to obtain reliable results by users with only limited experience in the characterization of porous materials.
-
Product
Impulsive Sound Source
BAS006
-
The BAS006 is an innovative device used to create impulsive noise that includes low frequency energy and avoids problems like secondary bounce. These characteristics make it a great choice for quickly measuring reverberation time when the complexity and weight of a speaker and amplifier is not needed.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Compact Receiver Module
MixAMC-I
-
Virginia Diodes'' standard Spectrum Analyzer Extension Modules (SAXs) provide high performance broadband down-conversion and frequency extension of microwave specturm analyzers into the THz range. VDI now offers integrated MixAMC modules that provide industry leading performance in a compact package. These integrated MixAMC modules are used to down-convert millimeter-wave / THz signals only. Spectrum Analyzer Extension mode is not currently available for the MixAMC-I products. Integrated MixAMC modules utilize a low frequency LO input (<20 GHz) and have a seprate IF output port. Integrated MixAMC modules configured for high IF bandwidth may be available upon request.
-
Product
8-Channel VME Tachometer
V360
-
The V360 is a single-width, 6U height VME module designed specifically to acquire low frequency inputs from industrial speed sensors. The module can measure frequency and period over a wide dynamic range, and is specifically designed to ensure reliable measurement in high-noise industrial environments.
-
Product
Vibration Pickup
-
Constructed so that each Piezoelectric element has shear that is proportional to applied acceleration between the poles. It is useful for low frequency vibration measurement even in the environments of large temperature change because of it is hard to be effected by the Pyroelectricity. Furthermore, it is less sensitive to the strain in the base.
-
Product
Low/Mid-Frequency Power Systems
-
Advanced Energy’s low- and mid-frequency power supplies offer highly efficient, easy-to-integrate power. Quickly improve process control in a wide variety of applications.
-
Product
Frequency Up Converters
-
Are integrated assemblies that convert low frequency RF signals to higher frequency RF signals.
-
Product
Vibrational Analysis
GEMINI-2
-
GEMINI-2 is the compact solution for HVSR, MASW and Vibrational Analysis: a single waterproof container with integrated high-performance 3D geophone and low resonance frequency (2Hz sensors, suitably coupled) and a powerful real 24-bit acquisition card with USB port for connection to an external PC.
-
Product
Full Band Scalar Network Analyzer Extenders
-
Full band scalar network analyzer extenders are designed to extend low frequency scalar network analyzers to higher millimeterwave frequency ranges. These extenders offer a low cost means of producing millimeterwave scalar network analyzers while preserving the functionality and features that industry standard models offer. These extenders deliver a superior performance since they are assembled with SAGE Millimeter’s instrumentation grade frequency extenders (STE series), Faraday isolators (STF series), direct or programmable attenuators (STA series), directional couplers (SWD series) and waveguide detectors (STD series). The below standard offering covers the frequency range of 26.5 to 170 GHz. Specifications other than those listed below are available upon request.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
HiPot Tester
HiPot-30
-
The SURETECH HiPot 30 tester provides an economical solution to Low frequency AC and DC testing of cables,terminations, motors, generators and other electrical apparatus. 0 – 30kV
-
Product
Passive Probes
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Energy Saving Static Converter
-
The ENERGY SAVING static converter serves to generate a controlled squarewave single-phase alternate voltage (low frequency: 25 ÷ 125Hz) for industrial applications requiring high load power supplied by an external matching transformer. The power supply, sectioned by remote control switch and external fuses, is fed by a three-phase electric line via uncontrolled diode bridge and filtered by inductor and capacitor battery. The DC voltage thus obtained is converted into single-phase alternating voltage via “H”-shape bridge of semiconductors in order to control impressed frequency single-phase transformers.