Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
Product
Standard 1.00 (28.00) - 2.30 (65.00) Non Replaceable General Purpose Probe
P2532-1
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 156Test Center (mm): 3.96Full Travel (mil): 139Full Travel (mm): 3.53Recommended Travel (mil): 93Recommended Travel (mm): 2.36Overall Length (mil): 812Overall Length (mm): 20.62Rec. Mounting Hole Size (mil): 94.5Rec. Mounting Hole Size (mm): 2.40Recommended Drill Size: #41 or 2.40 mm
-
Product
ITO Sheet Resistance Standards (ITOSRS)
-
Indium Tin Oxide Sheet Resistance Standards (ITOSRS) from VLSI Standards are NIST-traceable products, intended for calibration of both contact and non-contact sheet resistance measurement tools used in the LCD, flat panel and touch-screen markets.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-F180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Switchable Fixed Frequency Synthesizer
EXP Series 2.25" x 2.25" x 0.6"
-
*Connectorized Package *Switches Between Multiple Fixed Frequencies *Exceptionally-Low Phase Noise *DRO Replacement *High Vibration Design
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-FK180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25Z1-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standardized Bus Interface
IP-429-II
-
Connect to your Avionics with IP-429. Pick 2,4,6,or 8 ARINC 429 compatible receivers and 1, 2, 3, or 4 transmitters. Transorb protected IO. Software programmable transmit rates [100K or 12.5K]. Time Tag on received data. IndustryPack campatible with 8 or 32 Mhz. bus operation.
-
Product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
High Frequency Probe
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Standard Brinell Hardness Tester
BRIN400 Series
-
The Standard Brinell Hardness Tester - BRIN400 Series of closed loop Brinell hardness testers represent the latest in Brinell hardness testing technology. They are robust, reliable, proven and designed to meet a customer’s most demanding requirements in harsh industrial environments such as those found in foundries, forges and steelworks.
-
Product
DC Josephson Voltage Standard
-
The system enables a number of calibration and measurement functions for dc voltages:*Calibration of secondary standards*Calibration of linearities and accuracies of dc voltmeters in the measuring range from 0 to ± 10 V.*Extremely exact output of any reference voltages*Direct comparison of two voltage standard measuring systemsNo other measuring system in the world offers such a variety with the highest precision.
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50G
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Frequency Converter Upwards
UPCONVERTER 10 GHz VXI
-
The UPCONVERTER 10 GHz control software is VXI Plug & Play and does not depend on the module version. The software allows for automated calibration and verification of the main characteristics of the device.
-
Product
Audio Frequency Output Power Meter
-
PGP Electronics Private Limited
PGP Electronics AF Output Power meter, model 3301provides reliable measurement of Audio Frequency Output Power. The audio power output meter, measurable from 0.01mW to 30W in 12 decades with 10 different termination impedances with both balanced and un balanced inputs. The instrument is very useful to conduct students projects, design and test simple sub systems in laboratories. New improved design features provides reliable working even in adverse environments.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25B-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1L
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
Switch Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-C
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1Q1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Optical Frequency Combs
-
The Optical Frequency Comb technology is regarded as a breakthrough technology for measurements with highest accuracy. Lowest phase noise, stable supercontinuum, and turn-key operation make the Menlo Optical Frequency Comb solutions unique in accuracy and reliability. According to our principles: The best Optical Frequency Comb for any application.
-
Product
Standards Waveform Generator
3110A
-
The 3110A software is built around the simple concept of a waveform segment. Each waveform segment can have a unique waveform, (sine, square, triangle, and/or DC offset). Frequency, amplitude and DC offset can be clipped, fixed, variable or swept. Segments can be calibrated (as required in CS101) and set to continue on to the next segment or to hold for an external trigger.
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4T
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard Gain Horn Antenna
SAS-586
-
This Standard Gain Horn Antenna will provide reliable, repeatable measurements. An ideal solution and a standard workhorse of any EMC test house for compliance testing. Features: 12.4 GHz to 18 GHz, Individually Calibrated, FCC, MIL-STD, VDE and TEMPEST Testing.
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62J-4-S
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Robotics and Machine Vision Standards
-
Accuracy in machine vision systems is critical to achieving strategic goals regarding quality, efficiency, and consistency. Use our ACCUplace product lines to calibrate vision systems’ distortion, placement/alignment, or other field parameters in systems used for guidance, identification, gauging, and inspection. Using our specialized ACCUedge® technology, our Robotic and Machine Vision Standards are manufactured with line-edge quality that is second to none in the industry, providing the precision needed to calibrate almost any system. Should you need to alter feature patterns, size, or substrate to fit your needs, fill out our Optical Components and Standards form to start the conversation.
-
Product
Frequency & Pulse Distribution
-
Timetech frequency distribution amplifiers and pulse distribution units.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72U-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Connectors
-
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.