G.992.5
Doubles the bandwidth (ADSL) close up, boosts it nicely in middling ranges and pushes high-speed always-on data over telephone lines out to 18,000 feet.
-
Product
Measurement and Analytics Solutions
-
Based on our OTP² system platform, we were able to implement a family of scalable test systems which is based on a common systems architecture, e. g. for products in the area of chemical analytics measurement. We not only implemented a universal, extremely comprehensive test system, but also a series of compact systems for benchtop placement which are fully compatible with the larger, universal system. Our specialized self-test adapters and test software enable fast verification of the test systems as well as partly automated calibration by the customer.Our systems are also used in electrical measurement applications, e. g. for calibrating analog input assemblies for PLC technology. For this purpose, specialized calibrators are integrated into the system; they provide traceable calibration of the relevant stimulus signals.
-
Product
PLC Line Drivers
-
Renesas' PLC line drivers are commonly used in broadband HomePlug (IEEE 1901.1) and G.hn (ITU-T G.9960) applications, as well as narrowband PRIME and G3-PLS applications (CENELEC-A).
-
Product
Liquid Level Switch
CL-10GH
-
The Dynatrol® CL-10GH Liquid Level Detector and EC-501A(G) Control Unit is used for high, intermediate or low point level detection of liquids and slurries. A unique vibrating principle permits design and operation features not available with other types of liquid level detectors.
-
Product
Efficient All-In-One Test Solution for Low-Cost IoT Devices
KT RFCT 2400
-
The low price point creates a cost effective means for testing wireless communication units, while generating a favorable cost to performance ratio.The calibrated RF test system has a small footprint, integrating seamlessly into test system infrastructures via a single Ethernet connection. GPIOs control the DUT and peripherals. The test system enables communication interfaces like SPI, I2C, UART and CAN. Simple Go/No-Go tests can be performed in parallel. The KT-RFCT 2400A features a 70 MHz to 6 GHz frequency range and includes non-signaling and signaling connections. Bluetooth signaling standards are supported up to 4.1 as well as BT-LE. WIFI signaling standards supported are a, b, g, n and ac.The KT-RFCT 2400A is the perfect test system for a wide range of applications, such as Bluetooth, Infotainment, Keyless Entry, Tire Pressure Measurement, GPS and WIFI.
-
Product
3U 5-Slots OpenVPX P&G, w/o ROHS, 3.125G
101VPX305P-9K05
-
3U 5-Slots OpenVPX Power & Ground, Pass through, conformal coating, w/o ROHS, Max data rate (Gbps) 3.125.
-
Product
Module Type Amplifiers
-
Optical amplifier Gain Blocks are compact in size and suitable for built-in use. FiberLabs provides a wide wavelength range of optical amplifier Gain-Blocks over the O-, S-, C- and L-bands. These Gain Blocks can be used for B-PON system using three wavelengths of 1.31 μm, 1.49 μm, and 1.55 μm (ITU-T [compliant with G.983.3]), DWDM system and 100 GbE (IEEE 802.3ba) using the 1.3 μm band.
-
Product
IEPE Triaxial Accelerometer – 10 mV/g
HDP356A02
-
Triaxial accelerometer miniature for hand-arm measurement, ICP, 10mV/g, weight 4g, range 500 g pk
-
Product
Calibrator for Vibration Transducers
HD2060
-
Hand-held calibrator for vibration chains with frequency 15.915 Hz and levels 1 m/s² and 0.1 g, and frequency 159.155 Hz and levels 10 m/s² and 1 g. With LCD display.
-
Product
Digital Accelerometer
ZET 7152-N-VER.1
-
Digital accelerometer ZET 7152-N-VER.1 has a compact triaxial sensing element; it is purposed to measure linear acceleration and vibration acceleration variable component in three mutually perpendicular planes. Light weight of sensing element (only 1.5 g) considerably decreases self-mass load effect, and compact dimensions (8.5×8.5×8.5 mm) allow using ZET 7152-N-VER.1 digital accelerometer to measure vibration in small work-area systems.
-
Product
3U 1-Slot OpenVPX P&G, Aperture G, VITA 67.2/67.3B in J2A, Module
101V301P01-9002
-
3U 1-Slot OpenVPX Power & Ground, Aperture G supports VITA 67.2/67.3B in J2A, Module TE 1996777-2, Pass through with VITA 67.2 ctr, not ROHS compliant, max data rate (Gbps) 3.125.
-
Product
3U 1-Slot OpenVPX P&G, Aperture H, VITA 67.3C
101V301P04-9X13R
-
3U 1-Slot OpenVPX Power & Ground, Aperture H, Supports VITA 67.3C , Pass through, w/ROHS, Max data rate (Gbps) 25.
-
Product
Constant Acceleration Tester-Arm Type
KRD31 series
-
KRD31 series constant acceleration tester are used to test articles under extreme acceleration conditions based on standard like MIL-STD-810F, MIL-STD-202 and IEC68-2-7. It is most suitable for testing electronic components or devices. Under high g effect on microcircuits, to check adaptability and reliability of wiring and the internal structures. It may expose mechanical and structural defects that are not found with vibration and shock tests.
-
Product
3U VPX 1 Slot P&G w VITA 67.3C aperture 10G
101V301P04-9X12R
-
Power for 3.3V, 5V and 12V are included, rear connectors are all fully loaded, use with Elma’s slot to slot or slot to I/O bulkhead cable products during system development.
-
Product
Military & Aerospace EMC Testing
-
EMC Technologies’ Melbourne and Sydney and also EMC Bayswater (south-east Melbourne) laboratories provide NATA accredited Electromagnetic Compatibility (EMC) MIL-STD testing of military equipment to MIL-STD 461 B, C, D, E, F & G. The scope includes most test requirements and methods called up by MIL-STD 461/2, allowing defence agencies, contractors and defence suppliers to prove compliance with the stringent EMC limits imposed on defence equipment and systems.
-
Product
3U 1-Slot OpenVPX P&G, Aperture J
101V301P05-9X12R
-
3U 1-Slot OpenVPX Power & Ground, Aperture J, Supports VITA 67.3D , Pass through, w/ROHS, Max data rate (Gbps) 10.
-
Product
Hot sale Window Tint Meter WTM-1100
WTM-1100
-
Guangzhou Landtek Instruments Co. Ltd.
Window Tint Meter WTM-1100Applications:Window Tint Meter WTM-1100 is applicable to measure the transmittance or haze of all kinds of transparent, translucent samples withparallel plane.Details:Display:10mm LCDMeasurement Range:0 to 100% Light TransmissionResolution:0.1Accuracy:± 2 %Sample Thickness:Less Than 18mm / 0.7inchLight Source:LEDMeasuring Mode:Single / ContinuousOperating conditions:Temperature: 0 ~ 50 ℃ Humidity: < 90 %Power Supply:4 x 1.5 V AAA Size (UM-4) BatteryDimensions:Unit: 126 x 65 x 27 mm (5.0 x 2.6 x 1.1 inch)Sensor: 125 x 38 x 38 mmWeight:100 g (Not Including Batteries)Accessories:Standard Accessories1. Main Unit2. Carrying Case3. Operation ManualOptional Accessories1. USB, RS-232C data cable with software2. Bluetooth data out put with softwareFor window tint meter price , please feel free to contact Lisa. Thank you!
-
Product
Portable Converged Networks Test Set
TX Series
-
The VeEX TX product series offers a complete test solution for Next Generation of Transport, Metro and Carrier Ethernet Testing. Color graphical display assisted with touch panel enables users tapping through the test configuration and accessing complex overhead bits and bytes. Features include APS, TDM, pointer adjustment, pulse mask analysis, G.821/G.826/M.2100, histogram, and overhead access.
-
Product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
-
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
Product
GPON ONT
ONT-2GF-V-W
-
Hangzhou Softel Optic Co., Ltd.
ONT-2GF-V-W is a residential gateway device with routing functions for XPON ONU and LAN Switch for residential and SOHO users, which is in line with ITU-T G.984 and IEEE802.3ah. The uplink of ONT-2GF-V-W provides one PON interface, while downlink provides two Ethernet one POTS and WiFi interfaces. It can realize optical access solutions such as FTTH (Fiber To The Home) and FTTB (Fiber To The Building). It fully integrates the reliability, maintainability and security design of carrier-grade equipment, and provides customers with the last kilometer of broadband access to residential and corporate customers.
-
Product
Micropower, 3-Axis, ±200 g Digital Output, MEMS
ADXL372
-
The ADXL372 is an ultralow power, 3-axis, ±200 g MEMS accelerometer that consumes 22 μA at a 3200 Hz output data rate (ODR). The ADXL372 does not power cycle its front end to achieve its low power operation and therefore does not run the risk of aliasing the output of the sensor. In addition to its ultralow power consumption, the ADXL372 has many features to enable impact detection while providing system level power reduction. The device includes a deep multimode output first in, first out (FIFO), several activity detection modes, and a method for capturing only the peak acceleration of over threshold events. Applications: Impact and shock detection. Asset health assessment. Portable Internet of Things (IoT) edge nodes. Concussion and head trauma detection.
-
Product
Gauss Meters
-
A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.
-
Product
Insulation Tester
AD-225
-
3 Measurement voltage range: 500 V; 1000 V and 2500 V, Control of measuring voltage during measurement, Insulation measurement up to 100 G W, Elimination of trough resistance insulation ? 3 connectors measurement method, Autoranging,
-
Product
Insulation Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
The insulation resistance (IR) test (also commonly known as a Megger) is a spot insulation test which uses an applied DC voltage (typically either 250Vdc, 500Vdc or 1,000Vdc for low voltage equipment <600V and 2,500Vdc and 5,000Vdc for high voltage equipment) to measure insulation resistance in either k, M or G.
-
Product
Voltage Input Device For FieldDAQ
-
The Voltage Input Device for FieldDAQ measures up to eight ±10 V channels with 24-bit resolution and simultaneous sample rates up to 100 kS/s/ch. Some models can power sensors, such as pressure sensors, with up to 24 V per input channel. This device offers 500 V channel-to-channel isolation, protecting instrumentation from high-transient voltages. Additionally, the device is IP65 and IP67 rated to be dust-proof and water-submersible, can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. It has an integrated network switch for simplified daisy chaining and provides tight synchronization over time sensitive networking (TSN) for distributed data acquisition systems.The Voltage Input Device for FieldDAQ includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
Chlorine Meters
-
Water chlorination is the process of adding chlorine (Cl2) to water as a method of water purification to make it fit for human consumption as drinking water. Sper Scientific offers Chlorine meters that meet the standard method 4500-CI G for drinking water and the ISO 7027 standards.
-
Product
Atmospheric Pressure Sensor
SBS-02A
-
Provides: Altitude and rate of climb/descent data. Range: 500-1100hPA or 162.4-16,000 feet (-50 to +5500 meters). Weight: 0.10 oz. (2.7 g)
-
Product
3U 1-Slot OpenVPX P&G, Aperture E, VITA
101V301P03-9006
-
3U 1-Slot OpenVPX Power & Ground, Aperture E, Supports VITA 66.4/67.3A/67.1 in J2B, Module TE 2226880-1, Pass through with VITA 66.4 ctr in J2B and RT2-R ruggedized VPX conn, w/o ROHS, Max data rate (Gbps) 3.125.
-
Product
Magnetic Permeability Meter Ferromaster
-
Instrument for easy measurement of the relative magnetic permeability µr of feebly magnetic materials and workpieces with a permeability between 1.001 and 1.999. The permeability is measured by touching the workpiece with the probe tip and reading the result from the display. Typical applications are: non-destructive testing of materials, e. g. quality control of stainless steel, material selection for electron-/ion-beam equipment, detection of material defects induced by mechanical or thermal stress.
-
Product
3U 1-Slot OpenVPX P&G, Aperture E, VITA 66.4/67.3A/67.1 in J2B, Module
101V301P03-9004
-
3U 1-Slot OpenVPX Power & Ground, Aperture E, Supports VITA 66.4/67.3A/67.1 in J2B, Module TE 2226880-1, Pass through with VITA 66.4 ctr in J2B and RT2-R ruggedized VPX conn, w/o ROHS, Max data rate (Gbps) 3.125.
-
Product
Spacecraft Power Bus Simulator
-
AMETEK Programmable Power, Inc.
*Provides enhanced measurement and data-logging of up to 40 channels.*Bus Power Monitoring Unit (BPMU) can be easily relocated to TVAC chamber to ease cabling complications*Data can be viewed either in spreadsheet or graphical format*Spacecraft (Payload) Protection Unit (SPU) provides 10 μsec reaction to out-of-tolerance conditions g