MUX
Combine multiple signals into one signal.
-
Product
PXI Dual 2 Channel Fiber MUX SC
40-855-222-M
Switch Module
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
Product
PXI Single SP4T MUX 40GHz 50Ω SMA-2.9
40-784-141
Multiplexer Module
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode
40-850A-014-M50-HI
Multiplexer Module
The 40/42-850A-014-M50-HI is a PXI/PXIe 4-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI Octal 3:1 High Voltage Power MUX
40-331-005
Multiplexer Module
The Pickering Interfaces 40-331/332 High Voltage Power Multiplexer and Matrix Modules are suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. The 40-331 is available as a single 24:1, dual 12:1, quad 6:1, hex 4:1, octal 3:1 or twelve 2:1 multiplexer, and the 40-332 is available in 12x2 or 6x4 matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
Product
PXI 5A MUX, 1-Bank, 48-Chan, Ind. Isolation
40-651-101
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
Product
PXI Very High Density Versatile 2-Pole MUX
40-613-002
Multiplexer Module
The 40-613 Very High Density Versatile 2-pole Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves.
-
Product
PXI High Density MUX BRIC, 10-Chan, 80-Pole
40-570-115
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode
40-850A-414-M50
Multiplexer Module
The 40/42-850A-414-M50 is a PXI/PXIe 4-channel multiplexer with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI 2 Amp MUX, Dual 16-Channel 1-Pole
40-635-105
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 3A Power MUX BRIC, 6-Channel, 48-Pole
40-571-006
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PCI High Density Screened MUX 99 Ch 1 Pole
50-670-021-S-99/1
Multiplexer Module
The 50-670 series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI 2 Amp MUX, Quad 4-Channel 2-Pole
40-635-109
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PCI High Density Screened MUX 49 Ch 2 Pole
50-670-021-S-49/2
Multiplexer Module
The 50-670 series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.The 50-670 shares exactly the same architecture as the established PXI 40-670 module.
-
Product
High Density 1xN mux or 2xN Matrix Switching Systems
JX Series
-
This compact and economically priced series can be used as either 1xN multiplexers, 2xN matrices, or individual switches. As multiplexers, they can be used as a large number of individual muxes or jumpered together to form as large a mux as you need to switch a large number of inputs or outputs to one common port. As a 2xN matrix they allow you to switch any number of signals between two ports of a DVM, DMM, LCR, or other type of meter or supply. Individual relay modules are available for other configurations requiring discrete SPST or SPDT relays with standard or power relays.
-
Product
LXI 16:1 Optical MUX LC Single Mode
60-850-413
Multiplexer Module
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber
40-852A-318-M50-HI
Multiplexer Module
The 40/42-852A-318-M50 is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe MEMS Optical MUX, Single 2-Channel, Single-Mode
40-855A-112
Multiplexer Module
The 40/42-855A-112 is a PXI/PXIe 2-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
LXI 8:1 Optical MUX LC Loop-Thru
60-850-421
Multiplexer Module
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
Product
PXI 5A Power MUX, 4-Bank, 11-Channel
40-651-003
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
Product
PXI High Density MUX 94-Channel 1-Pole
40-640-022-94/1
Multiplexer Module
This series of high density multiplexer modules feature a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The multiplexer module is available as a 47-channel 2-pole, 94-channel 1-pole or 47-channel 1-pole with screened relays. Connections are made via a front panel 96-pin connector. It may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available for this 1-pole version).
-
Product
PXI/PXIe MEMS Optical MUX, Single 2-Channel, Multi-Mode, 62.5/125 Fiber
40-855A-512-M-HI
Multiplexer Module
The 40/42-855A-512-M-HI is a PXI/PXIe 2-channel multiplexer with ST connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI 3A Power MUX BRIC, 8-Channel, 12-Pole
40-571-302
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI Dual 12:1 High Voltage Power MUX
40-331-002
Multiplexer Module
The Pickering Interfaces 40-331/332 High Voltage Power Multiplexer and Matrix Modules are suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. The 40-331 is available as a single 24:1, dual 12:1, quad 6:1, hex 4:1, octal 3:1 or twelve 2:1 multiplexer, and the 40-332 is available in 12x2 or 6x4 matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
Product
PXI 10A Power MUX, 2-Bank, 8-Channel
40-661-102
Multiplexer Module
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber
40-850A-214-M62.5-HI
Multiplexer Module
The 40/42-850A-214-M62.5-HI is a PXI/PXIe 4-channel multiplexer with SC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI Dual 6 Chan Mux 18GHz 50ohm SMA
40-785-522
Multiplexer Module
Pickering Interfaces PXI Microwave multiplexer modules are suitable for switching 50_ signals up to 40GHz. The 40-785 is available as a single or dual 6 channel multiplexer, with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
LXI Dual 8:1 Optic MUX SC Loop-Thru
60-851-222
Multiplexer Module
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
Product
PXI 3A Power MUX BRIC, 10-Channel, 24-Pole
40-571-105
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI Solid State MUX, 4 pole, 40 channel
40-680-404
Multiplexer Module
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode
40-850A-214-M50
Multiplexer Module
The 40/42-850A-214-M50 is a PXI/PXIe 4-channel multiplexer with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.

























