Filter Results By:
Products
Applications
Manufacturers
Ionizers
Neutralize static charge.
- 
			
		
			product Analog Ionizing Radiation DetectorsA great general purpose analog radiation detector. Detects from 0-50 mR/hr. 
- 
			
		
			product Bench Top IonizersPoint-Of-Use Ionizer, Adjustable (30-100 PSI) Compressed Air IonizerNeutralize Electrostatic Attraction (ESA) to control contamination by dislodging dust and debris attracted by static electricity.Detachable 7'' long ESD Protective Flexible Hose with Thumb Button Designed to for a wide range of motion and simple operation.Adjustable Balance (20 Volts) with Less Than 1 Second Discharge Time At 6 InchMeets required limits ANSI/ESD S20.20 tested per ANSI/ESDSTM3.1 and ESD TR53 
- 
			
		
			product Nexis GC-2030 BIDUFRGAUFRGA Series The Ultrafast RGA system utilizes the new Barrier Discharge Ionization Detector (BID) technology coupled with Nexis GC-2030 to create new system GC for ultrafast, high-sensitivity analysis. Since the electrode creating Helium plasma is totally isolated from the carrier gas, there is no chance to contaminate this electrode with a dirty sample. This enables long-term stability. 
- 
			
		
			product PRODUCTS TESTINGESD MicroStat Laboratories -R.E.T.S. Our ESD test capabilities include resistance, resistivity, electrostatic shielding, charge generation, and charge dissipation. We routinely test flooring materials, packaging, footwear, garments, ionizers and many other ESD control products and materials. We utilize the relevant test methods and standards of the ESD Association, ANSI, ASTM, NFPA, IEST, IEC, AATCC, or our clients’ in-house specifications. 
- 
			
		
			product Mass SpectrometrySQ Detector 2 Compatible with the broadest range of chromatography platforms and ionization sources, the SQ Detector 2 is the ultimate single quadrupole mass detector for chromatography. 
- 
			
		
			product Digital Static Field MeterModel 715B - Assess electrostatic fields or charge on objects- Measures up to ±19.99 kV at a distance of 1 inch- Accuracy of <±5% in both normal and ionized environments- Uses a chopper stabilized sensor- LED ranging lights for positioning the meter at the right distance- Zero function allows the display to be adjusted to zero (0)- Hold feature to lock the reading on the display- Low battery indicator on the display- 1-year limited warranty 
- 
			
		
			product Charge Plate MonitorsOur easy-to-use charge plate monitors allow you to accurately evaluate air ionization systems used to neutralize static charge accumulation. Benefit from our economical solutions and products that offer onboard data storage to automate ionization system testing. 
- 
			
		
			product Blood Ionized Calcium Pocket Water Quality MetersLAQUAtwin Ca-11C Milk fever, or Sub Clinical Hypocalcemia (SCH) is a significant problem with dairy cows. Total calcium levels in the cows’ blood drop after lactation. By measuring the ionized calcium levels of the blood directly cow side, the treatment can start sooner and is more effective. The new LAQUAtwin CA-11C has been specially developed for cow side measurement of ionized calcium in blood. Ionized calcium reflects more accurately the current calcemic blood situation compared to total blood calcium as it equals the free available calcium ions. 
- 
			
		
			product Anti Static BarsStatic bars, also known as, static eliminators or anti static bars, are a very cost effective way to remove static electricity on a web of material in a plastics, paper, glass, textile, and or film converting applications. All of these static bars are bi-polar ionization generators (produce both positive and negative ionization) to remove static electricity. Remember - A clean static bar is more effective. 
- 
			
		
			product Closed-loop Ionizer Controllers For Multichannel Voltage DetectionNovx 3352/3362 Simco-Ion’s Novx brand of Passive (Model 3352) and Active (Model 3362) Multi-fan Closed-loop Ionizer Controllers provide the capability to simultaneously detect, measure, record and monitor electrostatic voltages in multiple locations. The versatile antennas used with these systems allow their use in a variety of applications including monitoring sensitive workstations, in-tool voltages, or ionizer performance with the option of closed-loop control to select ionizer products. 
- 
			
		
			product Flame Ionization DetectorA flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation. 
- 
			
		
			product Test Line • Equipment For Testing For FunctionThe test equipment is used for qualitative functional testing of discharge power supply units and / or ionization units from the static line and air line (discharge). The devices are usually operated with a single button and indicate via LED, whether the device under review functions properly. 
- 
			
		
			product IonizersPanasonic Automotive & Industrial Systems Europe GmbH There are many production processes where electrostatic charges disturb smooth operation. To eliminate static, ionizers are used. One typical field of application is the semiconductor industry where the components are extremely sensitive and can even be damaged by high electric static charges. Another example is the printing industry: Here friction between the rollers and the paper generates static. The static makes the paper cling and not move correctly through the printing machine. Especially when printing on vinyl or plastics, electrostatic charges need to be removed. In the packaging industry, plastic sleeves or foils tend to stick to each other, which can be prevented with an ionizer eliminate static. A general problem in assembling processes is the adhesion of dust and dirt particles. Contamination of workpieces can be prevented by having static eliminators neutralize and blow away undesired particles. 
- 
			
		
			product Electrostatic Field Meter KitPFK-100B - Measure range & polarity of electrostatic fields in 1 volt or 10 volts increments- Charges from zero to over 1000 volts in less than 5 seconds- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Use with a datalogger to record measurements & create reports- Compatible with the Autoanalysis System- Accuracy of ± 5%- Battery Operated 
- 
			
		
			product Static MetersETS static meters are offer accurate detection and measurement of static electricity found in the manufacture and handling of electronic, paper, plastic, textile, food, chemical, biomedical, and pharmaceutical products. In addition, these meters are invaluable for use in computer rooms, cleanrooms, hazardous environments, hospitals, and other locations that require the measurement of electrostatic fields. Chopper-stabilized models enable measurements in ionized environments. 
- 
			
		
			product Radiation And Process Monitoring SystemsProTK Monitoring of the main steam line for leakages in a PWR nuclear power plant with a wide-range gamma ionization chamber. 
- 
			
		
			product Deep Ultraviolet Spectrophotometer SystemVUVAS-10X A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions. 
- 
			
		
			product Ionization SourcesBaySpec offers many types of ionization sources to use with our Portability™ and Continuity™ portable mass spectrometers. Delivering ultimate mobility and ease of use, BaySpec’s Portability™ and Continuity™ are compatible with ambient ionization techniques, which do not require any gases or tanks to run measurements. Making it ideal for field analysis, ambient ionization does not require sample preparation; sample introduction quick, direct, and easy to perform by anyone in any location. Providing flexibility to perform applications using various ionization techniques, the external ionization sources can also easily be swapped in less than a minute. 
- 
			
		
			product Collapsible 6 Inch Charge Plate Monitor AssemblyCPM-760A - 6" x 6" (15 cm x 15 cm) conductive plate- Total system capacitance of 20 pF ± 2 pF- Meets the requirements of ANSI/ESD STM3.1 and ANSI/ESD SP3.3- Designed to perform audits on overhead ionizers and room ionization systems- Flexible to also evaluate and balance bench top ionizers- Completely collapsible for compact storage- Designed to be used with the PFM-711A and PFM-711B 
- 
			
		
			product Geiger CountersA geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings. 
- 
			
		
			product Radiation MicrodosimetersTeledyne e2v HiRel Microdosimeter is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test mass. The test mass simulates silicon die of integrated circuits on-board a host spacecraft in critical mission payloads and subsystems. By accurately measuring the energy absorbed from electrons, protons, and gamma rays, an estimate of the dose absorbed by other electronic devices on the same vehicle can be made. The Microdosimeter can operate from a wide range of input voltages. The accumulated dose is presented to three dc linear outputs and one pseudo-logarithmic output giving a dose resolution of 14 µrads and a measurement range up to 40 krads. These outputs are intended to be directly connected to most analog-to-digital converters (ADCs) or spacecraft housekeeping analog inputs (0-5 V range), which makes minimal demands on the host vehicle. The Microdosimeter incorporates a test function to allow electrical testing of the hybrid without the need for a radiation source. 
- 
			
		
			product Gamma DetectorsIn Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production 
- 
			
		
			product Portable Mass SpectrometerContinuity Continuity™ - the most sensitive portable mass spectrometer designed to provide quality and reliable mass spectrometer analysis outside of the laboratory. Continuity™ was created to provide even higher sensitivity, greater specificity with built-in MS/MS, and larger mass range coverage than its ground-breaking counterpart Portability™. Like its counterpart, Continuity™ requires no sample preparation and is compatible with almost any ambient ionization source including ESI, APCI, TD-ESI, TD-APCI, and DBDI. It allows for a broad range of applications from clinical to drug to chemical and biological threats analysis. The user-friendly interface, rapid deployment, and real-time results make Continuity™ a great solution for fast, dependable, and highly sensitive field analysis for any user in any location. This potable mass spectrometer is the excellent solution for various challenging applications, including vapors/liquids/solids, CWAs/TICs, biological/biomedical, forensic, agriculture, food safety, security, and explosives. 
- 
			
		
			product Charged Plate MonitorModel 280A Simco-Ion’s Model 280A incorporates enhanced circuitry that enables it to more accurately measure the performance of high frequency AC ionizers, as well as pulsed DC ionizers and steady-state DC ionizers. The Model 280A can be used as a portable CPM and is capable for of up to 6 hours of operation on the internal battery before recharge. 
- 
			
		
			product Walker Test SetPGA-710B A unique electrostatic data analysis device for use with Prostat’s PFK-100 Field meter/Charge Plate Monitor Set.• Records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltageretention, ionizer performance and other static measuring functions.• Creates detailed reports to help determine the risk of equaling or exceeding damaging or hazardous HBM dischargevoltages in static sensitive facilities.• Analyze Footwear & Flooring Combinations: Records personnel walking voltages in accordance with ANSI/ESD STM97.2 Body Voltage measurements as required by ANSI/ESD S 20.20 ESD Program Standard• Other Equipment Applications include voltage generation of chairs, carts and process equipment 
- 
			
		
			product Digital Ionizing Radiation DetectorsAll the numerous features of the SEI Inspector USB wrapped up in a rugged protective boot. For surveys in the field or on the move, this is a great option to protect your detector. 
- 
			
		
			product Radiation DetectorsA radiation detector is a device for measuring nuclear, electromagnetic or light radiation. A nuclear radiation detector identifies nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a geiger counter, a nuclear radiation detector consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or nuclear radiation detector. 
- 
			
		
			product Geiger-Muller CounterNukeMeter This hand-held ionizing radiation detector combinesa traditional look-and-feel with modern technology,providing an easy-to-use and portable solution. 
- 
			
		
			product Analytical BalanecesAT-R Series Basic Model with Improved Convenience.*Freely set responsiveness or stability*Connect with a computer via USB or RS232C*Perform stable measurements in combination with an ionizer 
- 
			
		
			product Ionization Test SetPFK-105 - Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included 






























