Rugged, Long Gauge Length Extensometers
Model 3543
Jinan Testing Equipment IE Corporation
With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
High Temperature Furnace COD Gages (1200 C or 1600 C)
Model 3548COD
Jinan Testing Equipment IE Corporation
These COD gages mount on a water-cooled bracket, which is mounted on the furnace side cut-out or with optional load frame support brackets. The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. Mounting brackets may be integrated with the furnace cut-out. Epsilon can also provide optional load frame mounting brackets to fit your test frame. Contact edges on the test sample should be somewhat rounded (not sharp knife edges) for best performance with this model. The Model 3548COD extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Long Travel Extensometers
The first type is specifically aimed at the plastic and rubber industries to provide accurate readings of strain and extension over a large extension range. The unit, incorporating two clamping arms and precision potentiometers, produces a DC voltage proportional to the distance between the arms. This generates accurate readings of percentage strain and allows additional parameters such as yield point and break points to be calculated when used with NEXYGENPlus software.
-
product
Universal Testing Machine:UTM Micro
Until now, testing of very delicate and small mechanical parts such as bearings, springs, microwires, organic fibers, and micro-electro-mechanical devices was not possible with conventional universal testing machines. But Anton Paar’s universal testing machine, UTM Micro, based on the renowned Anton Paar MCR rheometer, opens up a new world of material testing. The versatile UTM machine’s sensitive MCR technology, combined with its proven modularity, and an integrated extensometer and load cell, allows you to go beyond just tensile testing. You’ll now be able to rise to all kinds of challenges, even in the fields of DMA and optical methods.
-
product
Semi-automatic tensile testing machine
The controller of this testing machine automatically applies an appropriate load and puts the extensometer between the gauge lines, etc. after the sample is set. It provides measurement with high repeatability.
-
product
High Temperature XY Planar Biaxial Extensometer 1200 C or 1600 C)
Model 7651
Jinan Testing Equipment IE Corporation
Model 7651 extensometers measure combined in-plane strains in flat cruciform specimens tested in machines capable of simultaneous X and Y (perpendicular) axial loading and on standard flat samples tested in pure tension. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7651 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to eliminate crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃(2900°F) high temperature option.
-
product
Deflection Gauge Extensometers
AMETEK Sensors, Test & Calibration
We supply a wide range of deflection gauge extensometers ideal for measuring deformation in three and four point bend tests and in compression testing applications.
-
product
Video Extensometers
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
product
High Temperature Diametral Extensometers (1000 C)
Model 3580
Jinan Testing Equipment IE Corporation
This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Static Axial Clip-On Extensionmeters
2630-100 Series
The Instron static axial clip-on extensometer delivers precise strain measurement for static tests by quickly clipping to specimens (metals, plastics, composites) with minimal attachment force. Its rugged cross-brace design resists distortion, includes built-in over-extension protection, and meets ASTM E83 / ISO 9513 standards — making it a reliable, high-accuracy option for general and temperature-controlled testing.
-
product
Custom Extensometers
Jinan Testing Equipment IE Corporation
Special biaxial extensometer for limiting dome height bulge tester for sheet metal formability testing. Simultaneous X and Y strain measurements are taken.
-
product
High Temperature, Low Strain, Extended Performance Capacitive Extensometers
Model 7650A
Jinan Testing Equipment IE Corporation
Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200℃ (2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.
-
product
Contacting Extensometers
AMETEK Sensors, Test & Calibration
The contacting extensometers are designed for accurate strain and extension measurement of a material up to a maximum sample thickness of 25 mm.
-
product
Sheet Metal r-Value Extensometers
Model 3575AVG
Jinan Testing Equipment IE Corporation
Designed for measuring r-values in sheet metal testing, this extensometer averages the lateral strain at two locations. This model may be used simultaneously with the Model 3542 axial extensometer.
-
product
Auto Calibration for Load & Extensiometer
Jinan Testing Equipment IE Corporation
TE electronic calibration module provides an easy way to calibrate load cell or extensometer and signal conditioning electronics without using a mechanical calibrator. It enables performing on-site electrical calibration and easy to periodically “spot check”, which will help ensure that the load cell and the extensometer and electronics are calibrated correctly.
-
product
Axial Extensometers
6 models in this group cover tension, compression and cyclic testing Huge variety of gauge lengths and measuring ranges Cover temperatures from -265 to +200 °C (-450 to +400 °F)
-
product
Biaxial Clip-on Extensionmeters
2650 Series
The Instron 2650 Series Biaxial Extensometers are ideally suited for testing a wide range of materials, including polymer matrix composites, metals, and plastics over a range of temperatures. Two sensors measure axial strain on opposite sides of the specimen and a third sensor measures transverse strain. The extensometers meet the calibration requirements of ASTM E83 class B1, ISO 9513 class 0.5, and ISO 527.
-
product
Software
Tinius Olsen provides software to meet your R&D and quality control needs, working simply, efficiently and accurately. Horizon makes all your testing as effortless as it should be. It carries out your testing and seamlessly integrates with your processes. VSS works with Horizon to control your video extensometer testing.
-
product
Long Gauge Length Axial Extensometers
Model 3542L
Jinan Testing Equipment IE Corporation
The dual flexure design makes the 3542L very rugged and insensitive to vibrations. These extensometers are designed for testing a wide range of materials including metals, plastics, composites and ceramics. Epsilon’s Model 3543 is recommended for applications requiring long gauge lengths and larger measuring ranges.The Model 3542L comes standard with Epsilon’s quick attach kit, making it easy to mount the extensometer on the test specimen. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The 3542L extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Transverse (Diametral) Extensometers
Model 3575
Jinan Testing Equipment IE Corporation
Designed for general purpose transverse or diametral strain measurement on axially loaded specimens. This model may be used simultaneously with the model 3542 axial extensometer.
-
product
Non-Contacting Video Extensometer
AVE3
The AVE3 is Instron’s most advanced extensometer, engineered for high-precision, non-contact strain measurement across a wide range of mechanical tests—including tension, compression, and flexure. Its adaptable design accommodates various specimen types, sizes, and elongation ranges, making it ideal for everything from delicate films to robust metals. By eliminating the need for clip-on devices, the AVE3 streamlines setup and ensures uninterrupted data collection through specimen failure, even in high-energy break scenarios, such as composites. Compatible with environmental chambers and fluid baths, it supports non-ambient testing with ease. With compliance to ISO 9513 and ASTM E83 and a fast 500 Hz data rate, the AVE3 delivers reliable performance for demanding testing standards.
-
product
SSG Series Strain Gauge Extensometers
Shimadzu’s SSG series of strain gauge extensometers are compliant with ISO, JIS, and ASTM tensile test standards, including those for plastics and metallic materials These lightweight, precision extensometers feature a wide elongation measurement range, while retaining the flexibility to measure using small gauge lengths, and support both rod and flat plate shaped specimens. Consisting of an elongation sensor and amplifier, this extensometer is suitable for use with metals and hard plastic materials, and is fastened securely to specimens with screws. Calibration using an extensometer calibrator allows the extensometer to meet JIS and ISO Class 0.5 and ASTM Class C standards for higher accuracy.
-
product
Transverse and Diametral Extensometers
3 models cover most any test requirement and can be used with axial extensometers at the same time. Miniature and standard units, also r-value units. Available options cover temperatures from -265 to +200 C (-450 to +400 F).
-
product
Automatic Extensometer
SIE-560A/560SA
To determine the suitability of a material for an application where it is under load, measuring its elongation is important. Measuring elongation enables determination of the elastic modulus (reversible elongation in the elastic region) by measuring the small initial elongation range, and determination of elongation at specimen failure, by measuring larger irreversible elongation in the plastic region. Shimadzu’s SIE-560A series automatic extensometers accomplish both of these measurements with high accuracy, and provide automated functions that increase testing efficiency and test reproducibility. Ideal for testing a wide variety of materials, including metallic materials, plastics, and composites, the SIE-560A series complies with ISO 527, JIS K 7161, and ASTM D638 standards for plastics tensile testing. In addition, the SIE-560A series supports strain-rate controlled metallic material tensile testing measurements specified in ISO 6892, JIS Z 2241, and ASTM E4
-
product
Averaging Extensometers for ASTM D5656 Shear Tests
Model 4013
Jinan Testing Equipment IE Corporation
The Model 4013 extensometer meets the requirements of ASTM D5656 for measuring the strain properties of an adhesive in shear. It uses different contact point spacing compared to the extensometer shown in D5656. This makes it much easier to mount and eliminates the slippage problems associated with the design shown in the ASTM standard. The Model 4013 is available with all of Epsilon’s temperature configurations. It has a 3.0 mm (0.12 inches) full scale measuring range. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 4013 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Diametral Extensometers for Rock and Concrete Testing
Model 3975
Jinan Testing Equipment IE Corporation
Designed for accurate measurement of small diametral strains such as those required to determine Poisson’s ratio of rock, concrete and asphalt samples. The units are designed to be used in conjunction with the Model 3542RA axial averaging extensometer.
-
product
Extensometers for Simple Performance Testing of Asphalt
Model 3909
Jinan Testing Equipment IE Corporation
Designed for measuring axial displacements in the simple performance tests prescribed by NCHRP Report 465, and determining dynamic modulus of hot mix asphalt per AASHTO TP062.
-
product
High Temperature Axial Torsional Extensometers (1200 C or 1600 C)
Model 7650
Jinan Testing Equipment IE Corporation
Model 7650 extensometers are primarily used on round specimens tested in bi-axial test machines capable of simultaneous axial and torsional loading. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to minimize crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.
-
product
High Temperature Transverse Extensometers (700 C)
Model 7675
Jinan Testing Equipment IE Corporation
Designed for transverse or diametral strain measurement in environmental chambers where the entire extensometer must be exposed to elevated temperatures. These capacitive extensometers may be used up to 700 C (1300 F) without any cooling.
-
product
Bi-Axial or Axial Averaging Extensometers
Model 3560
Jinan Testing Equipment IE Corporation
This extensometer is ideally suited for testing anisotropic materials such as advanced composites as well as for general purpose tests like determining Poisson’s ratio. The Model 3560BIA uses a design unique to Epsilon, where the knife edges remain parallel during the displacement. This approach greatly reduces crosstalk between axes and allows use on round or flat specimens with equal ease. These extensometers are very easy to mount. Integral springs hold the unit on the test sample. The parallel multiple flexure design makes these units very durable.The Model 3560AVG reads axial strain only as a single averaged output. It may also be supplied with two independent outputs, one measurement from each side of the specimen. This set-up is most commonly required when an indication of specimen bending is desired. The second version, the Model 3560BIA, includes both the averaged axial strain and the transverse strain. Again, this may also be configured as dual independent axial readings, which results in a three channel extensometer.The Model 3560 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.