DVB-T2
Digital Video Broadcasting – Second Generation Terrestrial
-
Product
Bench/System Precision Linear Regulated DC Power Supply With Digital Control, Single Or Triple Outputs, 105 To 242 Watts, With/without Remote Interfaces
QL Series II
-
Advanced dc power supplies, single or triple outputUp to 112 watts per outputVery high precision, very low noise, excellent dynamicsAdvanced user interface with numeric and rotary controlMultiple voltage/current ranges for increased flexibilityMultiple non-volatile memories for power supply set-upsSwitchable remote sense provides perfect load regulationComprehensive protection including OVP and OCP tripsCompact bench footprint; modular width for rack mountingAuxiliary output fully variable 1.00V to 6.00V at 3A with selectable voltage and current metering (T models)Bus programmable via USB, RS232, GPIB or LAN (P models)LAN interface is LXI compliantDuplicate power and sense terminals at rear (P models)
-
Product
Temperature Calibrator
Model KM-CAL-906
-
Kusam Electrical Industries Limited
This temperature Calibrator gives high accuracy of 0.02% for measure and source. It has dual display, 5 digits for measure and 6 digits for source & white LED for backlight. Volts, RTD & Thermocouple. It gives output up to 500W to 5kW and output for calibrating R, S, K, E, J, T, N, B, L, U type of Thermocouples RTD & Continuity.
-
Product
120W to 150W - Single Output
CUS150M Serie
-
*150W Convection rating (/U version)*ITE and Medical Certifications (2 x MOPP)*Class B Conducted and Radiated EMI*Suitable for Class I and II installations*Compact 2 x 4 x 1.24" footprint*Suitable for BF Rated Equipment*Operation up to 85°C Ambient
-
Product
C Series Counter Input Module
Input/Output Module
The C Series Counter Input Module features flexible, 32-bit counters. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can also directly connect sensors with open-collector or push-pull outputs by using an internal, switchable pull-up resistor. Additionally, you can use the C Series Counter Input Module to perform encoder position and velocity measurements as well as to synchronize the counters with other analog, digital, and counter measurements in your chassis.The C Series Counter Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
Flexible Implantable Microprobe
IT-21
-
IT-121 Flexible Implantable Microprobe - Implantable in semi-solids and tissue with 21 gauge needle (supplied). Ideal for subcutaneous and cranial temperatures in small animals. Also for immersion in various solutions. Totally sheathed in chemical resistant Teflon™. Maximum Temperature 150°C . Isolated. Probe diameter .016" (21 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.08 seconds.
-
Product
IEC 60884-1 Fig41 High Temperature Indentation Tester For Socket
CX-YH
-
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60884-1 High Temperature Indentation Test Device For Insulatio Material ndentation Device : For pressure tests on plug pin insulating sleeves at temperatures to 200° C with 2.5N loads, according to IEC60884-1 figure 41, BS1363 figure 10. This apparatus has a rectangular blade (see IEC60884-1 figure 41A) with an edge 0.7 mm wide, to be used in the case of round pins, or a blade having a round
-
Product
4-slot Fanless Industrial System With LGA1151 Socket 7th/6th Gen Intel® Core™ I7/i5/i3 & Celeron® Processor, Intel® Q170, Front-access I/O, PCIe And PCI Slots
IPC964-512-FL
-
The IPC964-512-FL is a 4-slot fanless barebone system with modular design and optimized expandability. The rugged industrial PC supports the high-performance 7th/6th generation Intel® Core™ and Celeron® processors with the Intel® Q170 chipset. The IPC964-512-FL features dual DDR4-2133 SO-DIMM slots with up to 32GB memory. For easy cabling and maintenance, the IP40-rated embedded system features a wide choice of front-accessible I/O interfaces, including two Gigabit LAN ports, four USB 3.0 ports, one VGA, one HDMI, one audio (Mic-in/Line-out), and three optional I/O modules - a 4-port isolated RS-232/422/485 module, an isolated 8-in/8-out DIO module, and a 2-port isolated RS-232/422/485 and 4-in/4-out DIO module. The compact industrial PC also provides four flexible PCI/PCIe expansion slots with three different combinations of expansion kits: one PCIe x16 and one PCIe x4; one PCIe x16 and one PCI; and two PCI. Additionally, it has a full-size PCI Express Mini Card slot for 3G/4G, GPS, Wi-Fi and Bluetooth connections, and comes with two easy-swappable 2.5” HDD trays for storage. To fit various industrial environments, the rugged modular industrial PC supports 24VDC (uMin=19V/uMax=30V) power input with a lockable terminal block-type connector and a wide operating temperature range of -10°C to +60°C.
-
Product
Embedded GPU Card With DP 1.4a
EAI-2100
-
MXM 3.1 Type A Intel Arc A370M Embedded GPU Card with DP 1.4a. Intel Arc A370M with 1550 MHz Base Clock, GDDR6 4GB 64 bit Memory, up to 4.198 TFLOPS. TGP 40W Low consumption with optional thermal kit, support 0-60°C working temperature.
-
Product
Cold Rooms
-
Our walk-in cold rooms offer reliable, efficient environmental controls for a variety of applications; including: GMP Storage and Cold Storage for Seed and Agricultural Products, Nutritional Supplements, and more. Our cold rooms are typically supplied with desiccant or refrigeration based dehumidification in order to maintain a low dew-point and prevent ice accumulation on both product and equipment surfaces. Typical temperatures for our cold rooms range from of 0o C to 10o C.
-
Product
cPSB 2.16 8 Slot - 6 w/cPCI & H.110, 2 FS - RoHS
108PS21608-0157R
-
CompactPCI CPSB 2.16 6U 8 slot, 6 w/cPCI & H.110, 2 fabric, RoHS, fully compliant to the PICMG 2.16 Packet Switching Backplane specification.
-
Product
PXIe-4340, PXI Displacement Input Module
785068-01
Displacement Input
The PXI Displacement Input Module supports 4-, 5-, and 6-wire AC linear variable differential transformer (LVDT) and AC rotary variable differential transformer (RVDT) measurements. The module simultaneously samples each analog input and sets the excitation frequency and voltage for each channel independently. You can set different timing, triggering, and sampling modes for each channel independently. Diagnostic features include self-calibration, overcurrent detection, and open coil detection.The PXI Displacement Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module
779994-02
Strain/Bridge Input Module
10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.
-
Product
Coating Thickness Gauge
456
-
The Elcometer 456 dry film thickness gauge is available in four different models. Each thickness gauge provides the user with increasing functionality - from the entry level Elcometer 456 Model E, to the top of the range Elcometer 456 Model T.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
VME J2 5 slot
101VMEJ205-0900R
-
VME J2 backplane 5 slot, compliant with ANSI/VITA 1-1994. The A+C rows are bussed in all slots. Also, row B has onboard, inboard termination.
-
Product
Copper, Type T (°C) Contact
-
Thermocouple contacts are manufactured from chromel or alumel alloys and are color-coded for easy identification. They are crimp terminated and easily inserted into connector modules and readily removed using a special removal tool.
-
Product
32-CH Sinking Type Digital Input EtherCAT Module
EPS-1132
Digital Input Module
*32-CH sinking type digital input*Quick removable European type connector*Slave module healthy monitoring*Wide operation temperature range: -20°C - 60°C*Compact size: 100 (L) x 100 (H) mm
-
Product
Single-channel Cable/terrestrial Receiver For PCIe
DTA-2138B
-
DekTec's PCIe hardware-based receiver for DVB-T2, T, C2, C and ISDB-T. With full support for single- and multi-PLP, as well as SISO and MISO, this low-profile card is perfectly compliant to DVB-T2 v1.3.1.
-
Product
Immersion Probe For Liquid
DPT-12
-
DPT-12 Immersion Probe for Liquids - 12'' #304 stainless steel welded shaft. Wooden Handle. Diameter is .3/16'' diameter. Immersible. Maximum temperature 350°C, Time constant 2 Seconds. 5 foot lead. Not isolated.
-
Product
GFCI Receptacle Tester
RT210
-
Conforms to UL Std 1436, Certified to CSA Std C22.2 #160.Built to withstand a 6.6 ft. (2m) drop.Operating temp: 32°F to 140°F (0°C to 40°C).Works on GFI outlets and confirms operation of the ground fault.Nominal Voltage: 110/125V AC at 50/60Hz in 3-wire outlet.
-
Product
Web Sensor
T3511
-
Web Sensor with relative humidity and temperature probe. The device is supplied with T+RH probe on the cable. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
Product
NI-9222 , ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
781397-01
Voltage Input Module
±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
Product
The Verifier
VC-2
-
Portable, battery operatedHighly accurate DC outputVerify any DC VoltmeterBattery test LEDWorks with T&R
-
Product
Temporal Artery Thermometers
-
Shenzhen Everbest Machinery Industry Co.,Ltd.
Body temp range: 30.0 to 43ºC/86ºF to 109ºFSurface temp range: 0 to 60ºC(32ºF to 140ºF)Basic accuracy: in mode of body +0.3ºC/+0.6ºFIn mode of surface +0.8ºC/+1.5ºFMeasuring distance: 5~15CMResponse time: 0.5 secondOver range indication: LCD will show "HI"/"Lo"Polarity Automatic (no indication for positive polarity)Minus (-) sign for negative polarityEmissivity: 0.95 fixed valueSpectral response: 6~14umPower off: automatic shut off after 7 secondsOperating temp.: 0ºC to 50ºC (32ºF to 122ºF)Storage temp. : -20ºC to 60ºC(-4ºF to 140ºF)Relative humidity: 10%~90% RH operating, <80% RH storagePower supply: 2X1.5V AAA batterySize (H x W x D): 131 x 82 x 35mmWeight: 130g
-
Product
Air Temperature Probe
U1183A
Air Temperature Probe
Measure dryer, transport pipe, and surrounding air temperature within the range of -50°C to 800°C.
-
Product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
779521-01
Strain/Bridge Input Module
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
Product
80 Channel Relay Switch
DP-VXI-4503
-
DP-VXI-4503 is a 80 channel, one Form C (SPDT) relay switch designed as a C size VXI module. This high density switch module is designed with a register based interface occupying only one VXI slot. This module uses two Form ‘C’ relay switches. Out of the two contacts in each relay, one is used to provide the status of the relay through read back and the other is used for switching purpose.The user can write the command for the selected channels on to the primary latch of the FPGA section. Readback is available to confirm the selected commands. On command, the data from the primary latch is transferred to the secondary latch. The relay driver section provides the necessary drive to switch ON the relays. The buffers in this section drive the relay coils.This module features a back plane trigger for VXI triggered operation. On receipt of the back plane trigger the programmed relays will be energised/de-energised. Alternatively, software trigger can be used.
-
Product
Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer
Model T360M
-
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
MIL-STD-1553 A / B Test And Simulation XMC Module
XMC-1553
-
*Dual redundant*1, 2 or 4 channels*Simultaneous bus controller, 31 remote terminals, bus monitor*Error entry and detection*FPGA based hardware architecture*Multi-level trigger for data acquisition and filtering*10 programmable, discrete I / O (up to 30V)*IRIG-B timecode encoder / decoder with free-running mode*Real-time recording and physical bus playback*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, LabView Real-Time and other systems
-
Product
Waveguide Directional Couplers
-
WR-42 to WR-10 waveguide sizes. Split block waveguide versions available. Available in 7 bands including K, Ka, Q, U, V, E, W from 18 GHz to 110 GHz. 30 dB typical directivity. E Bend and H Bend configurations available. 10 dB and 20 dB coupling values are offered.