Voltage Calibrators
An accurate voltage units of measure to facilitate comparison to and adjustment of instruments.
See Also: Voltage Sensors
-
Product
Surge Voltage Generator
SSG 500
-
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
Product
ChenYang Voltage Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
DC voltage sensor/transducer works according to Linear PhotoelectricalIsolation and is designed for applications to measurement and monitoring of DC voltage. Theoutput signal (DC voltage or current) of this transducer is proportional to the input DC voltage.They are suitable for measurements and long time monitoring of DC voltages and can applied topower supply management, DC motor drivers, battery chargers and systems etc.
-
Product
Horizontal Calibration Instruments (Lab)
THV
-
The horizontal THV instrument has been designed for calibration and certification of gauging equipment of small dimension. It allows easy and precise checking of plug gauges, ring gauges, thread plug gauges, test and dial indicators as well as measuring of high precision production parts.
-
Product
Voltage Testers
-
Electrical Receptacle Tester Instantly Displays Wiring Condition of Any Standard 3-Wire AC 110-120 OutletNeon Indicators Give Positive Indication of Current StatusCompact Unit Simply Plugs into any Standard 3 Wire/Grounded Receptacle (110–125 Volt AC Circuits)Tests for 6 Circuit Conditions: Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse & Correct WiringBlister PackedcULus ListedOrder Qty of 1 = 1 Piece
-
Product
Portable Protection Test Set and Calibrator
CMC 430
-
The CMC 430 is the preferred choice for test engineers in cases where excellent transportability is needed and three currents up to 12.5 A or six voltage outputs are sufficient. Its low weight of just 8.7 kg / 19.2 lbs, and robust design with its edge protection predisposes the device to every outdoor and indoor use.
-
Product
Meters for Current & Voltage
EE301-DCM-xx
-
LCD Current Readings:0-80.0 / 40.0 / 20.0. LCD Voltage Readings:0-50.0 / 150.0
-
Product
Micro-Ohmmeter Calibration Kit
LOM-530
-
The LOM-530 is convenient single unit containing a complete set of (5) working standard grade resistors for complete calibration of micro-ohmmeters. The standard resistance values are those used by the LOM-510A Microohmmeter/Milliohmmeter.
-
Product
NIST Calibration for D410-A
D410-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Multifunction Calibrators
-
Many of the calibrators we offer are multifunctional calibrators, that is because then you don’t need to carry so many devices and also don’t need to recalibrate several devices. For us the “multifunctional” means a calibrator that can measure and generate electrical, temperature and pressure signals.
-
Product
Calibration
-
Calibration of a measuring tool is an operation that allows an assessment of the accuracy of the measurement, and the adjustment of the measuring tool so that it is more accurate. In scientific formulation, calibration makes it possible to evaluate the measurement error.
-
Product
Calibration Blocks
-
Are used to assess and refine measurement equipment's correctness, and these calibration blocks come in various sizes and shapes.
-
Product
Voltage Converter
99539C
-
The model 99539C is an 8 channel wide dynamic range voltage to frequency converter of modular design.
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
High Voltage Probe
PD-28
-
Kusam Electrical Industries Limited
Most Digital Multimeters can measure AC Voltage up to 750 /1000V and DC Voltage upto 1000V DC. To extend the measuring range of the digital multi meter for low - power , high - voltage , high impedance circuits such as TV, Video Monitors.
-
Product
Universal Calibrators
-
We offer our clients an exclusive range of Universal Calibrators which is designed and manufactured by our technical team. Our range is designed using superior quality material, and is widely appreciated for its rugged designs and durability. Also, these are presented with dual operating ability of source & sink of signals that make them appropriate for labs and process plants. Further, our assortment is extensively used in the calibration of instruments, commissioning of field instruments, repair & maintenance of filed instruments and as millimeter with limited facilities in various industries, such as chemical, cement, textile, fertilizer and automobile.
-
Product
Calibration
-
Testwave LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send recall notices before your equipment calibration expires, and if we don't hear from you, we will call, to make sure you stay in compliance for your calibration requirements.
-
Product
Calibration Services
-
WTG's calibration package is more than just verification of performance specs. It is a complete package of services including inspection and maintenance. Our services uphold the value of the instrument and extend its lifetime.
-
Product
Calibration
-
Omega carries a broad selection of calibrators, testers, and accessories for ensuring fast, accurate, and stable readings for all your test applications.
-
Product
Multifunction Field Calibrator & Communicator
MC6-Ex
-
The MC6-Ex is an intrinsically safe field calibrator and communicator. It is ATEX and IECEx certified and can be used in all hazardous zones / divisions. The MC6-Ex includes a field communicator for HART, FOUNDATION Fieldbus and Profibus protocols. Each calibrator is delivered with a traceable, accredited calibration certificate as a standard. t is a documenting, multifunction calibrator and communicator that offers calibration capabilities for pressure, temperature and various electrical signals.
-
Product
Digital Voltage Testers
-
Wenzhou Zhengyuan Electronic Co., Ltd.
Your product description goes here.
-
Product
Voltage Tester
-
*Simple and user friendly*Check 1.2V - 230V AC & 12V DC directly*Check ground line and phase line and breakpoint of the AC directly*No battery is required
-
Product
Three-Phase Electric Power/Energy Calibrator
MC133Ci
-
The MC133Ci model is a compact one-housing three phase electric power/energy calibrator. It can supply the device under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
Product
Voltage Tester
1806
-
Wenzhou Zhengyuan Electronic Co., Ltd.
Live and neutral wire identification.
-
Product
Calibration Standards
-
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
Product
Torque Calibration
-
Our years of experience has show us that torque tools given the fact that they are mostly driven by large (and small) springs do tend to drift out of specification quicker than other measurement tools – we have the expertise in house to adjust your tools back into spec and of course provide before and after results.
-
Product
Calibration Kit
WR-12
-
This precision calibration kit contains a flush short, offset piece and broadband load which allows for a full 12-term port calibration.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
Trace Level Portable Gas Calibrator
Model T750U
-
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
Product
High Voltage System
HV-2
-
International Electro-Magnetics, Inc.
*Tests Power Transformers for Continuity, Ratio and Phase. Applied and Induced Potential and No-load Losses.*14 Conductor Switching Matrix will test 7 individual windings, 13 taps of one common winding or some combination thereof. (10 Amp current limit)*The System Control is Windows/Visual Basic based. Menu screens allow full selection of test parameters and sequence. Low voltage tests can be performed first, allowing defective parts to be rejected without proceeding to time consuming induced Potential dwell routines. Test data labeling and data acquisition software can be easily added to the system.