Interferometers
Combine waves to reveal their properties by measuring the pattern of interference.
See Also: Beam Splitters
-
Product
Automated Interferometer with Floating Pastille Technology
DAISI MT FP
-
The Daisi MT FP combines the Daisi MT-V3 with the new Floating Pastille fixture technology from DATA-PIXEL (patent pending). This major technological breakthrough for multi-fiber connector fixtures is perfectly suited for highly accurate X/Y endface angle measurements.
-
Product
Laser Head
5517CL
Laser Head
The Keysight 5517CL is used primarily in VME and PC based laser interferometer systems where the velocity of motion is faster, such as semiconductor lithography and flat panel applications. Option 009 allows a larger angular range of measurement by providing a 9 mm beam diameter for use with three-axis interferometers. Please contact Keysight for custom requirements.
-
Product
Turning Mirror
10769A
Plane Mirror
The 10769A is ideal for use in laser measurement and calibration applications. In the calibration of slant bed lathes, for example, the beam steering mirror deflects the beam from the laser head upward, through the interferometer, along the lathe's cross slide. One or more mirrors can also create a path from a laser head to an interferometer located in an otherwise inaccessible position, as in the case of a milling machine with a table that moves in only one axis.
-
Product
Laser Head
5517FL
Laser Head
The Keysight 5517FL is used primarily in VME and PC based laser interferometer systems where the velocity of motion is faster, such as semiconductor lithography and flat panel applications. Please contact Keysight for custom requirements.
-
Product
Remote Receiver
10780F
Receiver
The Keysight 10780F Remote Receiver with fiber-optic pickup provides maximum layout flexibility for Keysight laser interferometer positioning systems. Remote pickup capabilities allow mounting of the heat-dissipating receiver electronics away from measurement areas, resulting in high measurement stability, accuracy, and repeatability.
-
Product
Optics Height Adjuster and Post
10785A
Accessory Kit
The Keysight 10785A Height Adjuster and Post is used to precisely position optics devices associated with the 5530 Laser Calibration System, such as the 10766A Linear Interferometer. The height adjuster and post also facilitate adjustments in measurements such as pitch and yaw.
-
Product
Short Range Straightness Optics
10774A
Optical Module
The Keysight 10774A Short Range Straighness Optics combines a straightness interferometer and reflector to make measurements over a range of travel up to 3 m (10 ft). The optics form a highly-accurate optical straightedge that can measure the straightness of travel of machine-tool and measuring-machine coordinate motions with a resolution of 0.04 micrometer (1 uin).
-
Product
Wavelength Meter
-
HighFinesse/Ångstrom offers sensitive and compact wavelength meters with a large spectral range for high speed measurement of lasers. The optical unit consists of temperature-controlled Fizeau-based interferometers that are read out by photodiode arrays. The high absolute accuracy is achieved by use of solid state, non-moving optics.
-
Product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
-
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
Product
Laser Head
5517C
Laser Head
The Keysight 5517C is used primarily in VME and PC based laser interferometer systems where the velocity of motion is faster, such as semiconductor lithography and flat panel applications. Option 009 allows a larger angular range of measurement by providing a 9 mm beam diameter for use with three-axis interferometers. Please contact Keysight for custom requirements.
-
Product
Differential Interferometer
10715A
Differential Interferometer
The Keysight 10715A Differential Interferometer performs differential measurements between the supplied reference mirror and a measurement plane mirror. It provides exceptional long term stability. The 10715A minimizes dead path, and, because the entire optical path through the interferometer is common mode, it eliminates thermal drift in measurements. The resolution of the measurement is twice that of a linear or single-beam interferometer.
-
Product
1/4-Inch Cube Corner
10713D
Retroreflector
The Keysight 10713D is one component of a family of measurement optics that tailor interferometer systems for the physical layout and measurement requirements of individual applications. Configured with appropriate laser head and system electronics, the optics are part of a precise positioning system that improves product quality, increases yields, and facilitates manufacture of precision products.
-
Product
Fiber End-Face Inspection Interferometer
CLEAVEMETER 3D
-
The CLEAVEMETER 3D™ is a non-contact interferometer designed for inspecting the end-faces of cleaved or polished optical fibers with cladding diameters of 125 µm to 1200 µm. It gives immediate and precise information on important end-face properties such as flatness, perpendicularity, hackles and dust. Based on the NYFORS CLEAVEMETER 3D™ design, in addition to producing sharp fringe patterns it also generates three-dimensional images of the cleaved fiber end.
-
Product
33% Beam Splitter - BK7, fixed horizontal-bend mount
E1834E
Beam Splitter
The E1834E is a 33% beam splitter in a high performance horizontal mount that offer the high pointing stability for Keysight laser interferometer measurement system. The 8 flexure feet are designed for stable beam pointing.
-
Product
MFI Michelson Fiber Interferometer
-
OPTIPHASE , a leading supplier of ultra-high performance interferometric systems, offers Fiber Interferometers for use in precision test and measurement instrumentation as well as fiber sensing systems. These interferometers are driven by our own PZ1 Low-profile Fiber Stretcher with enhanced modulation, through a front panel BNC connector. Michelson and Mach-Zehnder interferometers are available in wavelengths from 1064 to 1550 nm. Each interferometer has a “zero meter” path mismatch which provides flexibility to change the delay length to match varying test applications. The standard length shipped is 50 meters. We also build custom interferometers.
-
Product
Adjustable Mount
10710A
Mounting Bracket
The Keysight 10710A adjustable optics mount makes alignment faster and easier. It is a convenient accessory for the Keysight 10700A and 10701A beam splitters, the 10705A interferometer, and the 10707A beam bender. It allows for 8 degrees tilt and yaw adjustments.
-
Product
Custom solutions
-
Novacam develops custom interferometric solutions to address particular inspection and imaging needs of specialized applications and OEM markets. Our modular interferometer components offer a superior and cost-effective platform for developing high-performance systems and assemblies. We will collaborate with your application experts to devise the optimal combination of inteferometric (OCT) hardware, non-contact fiber-based sensor probes, and system software.As needed, Novacam engineers: develop customized optical probes and inspection stations develop inline probe fixtures for production environments adapt Novacam standard interferometer component modules to suit your application help integrate Novacam systems or components with third-party tools write customized software
-
Product
2x2 Interferometric Couplers
-
Feasa manufactures a series of couplers, which are optimised for use in fiber interferometers. The couplers have a highly reflective end on one or more output ports and can be configures as 1x2 or 2x2.
-
Product
Leak Test System
NorCom 2020
-
The NorCom 2020 batch inspects up to 500 devices per cycle for both gross and ultra-fine leaks. The system incorporates a patented full field interferometer that produces reliable, repeatable leak test results. The system eliminates the need for helium mass spectroscopy or krypton testing for fine, and bubble leak testing for gross leaks.
-
Product
Linear Interferometer
10766A
Linear Interferometer
The Keysight 10766A Linear Interferometer is used for general purpose single axis measurements and can be employed when the interferometer is the moving component, instead of the measurement reflector. It has a rugged, thermally stable stainless steel housing.
-
Product
Entry-level Price Interferometer for Geometry Measurement of Single Fibers
3D SCOPE-V2
-
Specifically designed for use in a production environment, 3D Scope-V2 is a robust, compact and easy to use interferometer that brings speed and precision to operators. 3D Scope-V2 supports our Blink software platform. Non-compressed, real time and high quality images are transfered from the hardware to the software via a USB 2.0 link in addition to the automation and control commands.
-
Product
Interferometers
-
Sumix interferometers are designed for inspection of fiber optic ferrules, patch cords, pigtails and bare fiber in the process of polishing and assembly. They enable you to check polishing quality, test connector end face geometry per IEC, Telcordia or your own custom standards and generate reports to supply with your patch cords.
-
Product
Laser Interferometer Position Measurement Systems
-
When built into manufacturing and inspection equipment, a laser interferometer system reports the position or controls the motion of a product platform with more accuracy than any other method. It allows manufacturers to produce precision products from integrated circuits to medical devices to aerospace components that meet the most stringent specifications.
-
Product
Linear Interferometer
10702A
Linear Interferometer
The 10702A includes one 10703A Retroreflector as a reference reflector. A second 10703A is needed to complete the linear measurement optic set. The interferometer cannot be used to bend the beam. If the interferometer is the moving component, the 10702A Option 001 must be ordered. More about the 10703A Retroreflector
-
Product
Retroreflector
10704A
Retroreflector
The Keysight 10704A retroreflector (cube corner) is a measurement reflector for single-beam measurements. It is paired with the Keysight 10705A single beam interferometer and is designed for making limited space, single-axis measurements. If mass is critical, the Keysight 10704A is available without housing as the Keysight 10713C, and for extremely critical mass requirements, the Keysight 10713D 1/4-inch base retroreflector can be used.
-
Product
Create Topographic Profiles from SPM Images
TopoStitch
-
topoStitch™ offers the easiest and most accurate way to stitch topographic or greyscale images from Scanning Probe Microscopes (SPM’s), profilers, interferometers, confocal microscopes or any other instrument type. All images are placed automatically according to stage position coordinates when stored in the image files. Otherwise, the Grid Layout Wizard helps to lay out images in seconds. topoStitch™ even offers advanced snapping and semi transparent rendering, which makes it easy to place and adjust images manually.
-
Product
HES Spectrometers
-
ISI’s standard HES spectrometer offers a 100-fold increase in throughput over conventional systems currently available. This increased throughput can lead to a superior signal-to-noise ratio (SNR) for a given observation over a Czerny Turner instrument. The HES spectrometer contains no moving parts and yet offers the advantages of a Michelson Interferometer with the spectral properties of a traditional diffraction grating-based device, such as a Czerny Turner spectrometer.
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
Erbium Fiber Frequency Comb
-
Detailed description of item: The AOSense frequency comb is a low noise, polarization maintaining (PM) device. Key features include a PM fiber architecture centered at 1550nm with turnkey modelocking; a free-running linewidth of the carrier-envelope offset frequency of <200 kHz; a temperature-insensitive all-fiber f-2f interferometer exhibiting fceo beatnotes with SNR > 45dB (300kHz RBW); and dual fast/slow cavity length actuators with a bandwidth of >300 kHz. The repetition rate of the comb is factory set and allows matching across multiple combs for dual comb applications. The optics package incorporates an optical heterodyne module designed for locking to the comb to an ITU-specified laser reference. The comb is capable of supporting an Allan deviation of < 5 x 10-18 at 1 second and ~10-20 after 105 seconds. Add-on features include all fiber extensions to visible wavelengths corresponding to several atomic transitions. An integrated comb electronics package is currently under development.
-
Product
Ultra-High Resolution Spectrometers
-
Fabry-Pérot interferometers are optical resonators used for high-resolution spectroscopy. They use the phenomenon of multiple-beam interference that results when light shines through a cavity bounded by two reflective parallel surfaces. When the light hits one of the surfaces, some is transmitted out, and the remaining part is reflected back. Fabry-Pérot produces a circular fringe pattern, similar to the Michelson pattern. However, the fringes are thinning, brighter, and more widely spaced. As a result, these instruments are able to detect and resolve the fine features of a transmission spectrum with high precision.





























