Isolated Digital Input Modules
-
Product
48-Channel VME Isolated Digital Input Module
V280
-
The V280 is a single-wide, 6U VME module that includes 48 isolated logic inputs. It is available in versions for nominal 5 volt or 24 volt input levels. The V280 has independently programmable rising and falling edge response times to support contact debounce, glitch catching, and DC or AC inputs.
-
Product
16-Ch Isolated Digital Input Modules
ADAM-5051S
-
50 Vmax Input Voltage2500 Vdc Optical Isolation70 Vdc Over Voltage Protection16-channel
-
Product
15-CH Isolated Digital Input Module
ND-6054
-
- Channels: 15- Isolation Voltage: 5000 VRMS- Switching Level: with 24 V common power. Low (0): 22 V min.; High (1): 0-22 V- Programmable input polarity
-
Product
96 Channel Isolated Digital Input / Interrupt Output Module
DP-cPCI-3096
-
96 Channel Isolated Digital Input / Interrupt Output Module
-
Product
8-CH Isolated Digital Input Module
ND-6052
-
- Channels: 8 DI. 6 fully independent isolated; 2 isolated with common ground- Isolated Voltage: 5000 VRMS- Programmable input polarity
-
Product
8-Ch Isolated Digital Input Module
ADAM-5052
-
Digital input level: Logic level 0: +1 V max.Isolation voltage: 5000 VRMSPower consumption: 0.27 W (max)Channels: 8
-
Product
48 Channel Isolated Digital Input/Output Module
DP-VME-3078
-
DP-VME-3078 is a 48 Channel Isolated Digital Input Output Module. This module provides 48 input / interrupt channels and 48 digital output channels with isolation. The 48 channel inputs are divided into 12 groups, each group consisting of 4 channels and 1 common GND .The 48 output channels are divided into 6 groups, each group consisting of 8 channels and a common GND.
-
Product
16-Ch Digital Input EtherCAT Slice IO Module
AMAX-5052
-
Channels:16Digital Input;Dry Contact;Logic level 1: close to Iso.GND;Logic level 0: open;Wet Contact;Rated voltage: 24VDC;Logic level 1: 10~30 VDC;and -10~-30 VDC;Logic level 0: -3~3 VDCInput Delay:From logic level 0 to 1: 4ms;From logic level 1 to 0: 4msDigital Filter: 3ms
-
Product
32-Ch TTL And 32-Ch Isolated Digital I/O PCIE Card
PCIE-1730
-
32-ch isolated DI/O (16-ch digital input, 16-ch digital output)32-ch TTL DI/O (16-ch digital input,16-ch digital output)High output driving capacityInterrupt handling capability2 x 20-pin connectors for isolated DI/O channels and 2 for TTL DI/O channelsD-type connector for isolated input and output channelsHigh-voltage isolation on output channels (2,500 VDC)
-
Product
PXI/PXIe High Density Digital Input Module, 128-Channel, 50V
42-414-101
-
The 40-414-101 (PXI) and 42-414-101 (PXIe) are 128-channel digital input modules with 50 V inputs and provide a convenientway of determining the status of input lines by comparing the input voltage with two threshold voltages - quicklyestablishing if the input is low, high or in an intermediate logic state.
-
Product
32-Ch Isolated Digital I/O USB Module
USB-4750
-
Compatible with USB 1.1/2.0Bus-powered16 isolated DI and 16 isolated DO channelsHigh voltage isolation on all channels (2500 VDC)High sink current on isolated output channels (200 mA/Channels)Supports 5 ~ 60 VDC isolated input channelsInterrupt handling capabilityTimer/Counter capabilitySuitable for DIN-rail mountingOne lockable USB cable for secure connection included
-
Product
32-CH Discrete Input Modules with U Profile
HSL-DI32-UD
-
HSL U series is designed as compact & horizontal-placed slave module. For I/O module, ADLINK adopts three types of connectors to meet different users' requirements & habits. Compared with past models, U series brings compact size, easier-to-wire and cost-effective advantages for users. DI/O, AI/O and motion control module are supported
-
Product
32-CH ±10V Analog Input EtherCAT Module
EPS-3032
-
ADLINK" s EPS slave system features modular design for flexible high channel density, rugged construction, easy maintenance, and intelligent performance, compatible with 3rd party EtherCAT products. Precise time-deterministic control enables I/O synchronization for critical applications, and FPGA and ARM technology allow users to fully monitor status of EPS modules and systems, including operating temperature and usage cycle of relay switching, as well as motion control status for general purpose motor drive control. In addition, the ADLINK EtherCAT configurator enables auto-scan and configuration across EtherCAT systems. The EPS" unique structural and electronic design supports hot-swappable function, reducing repair time, and the rugged construction and operating temperature range of -20°C to 60°C allow operation in the harshest environments.
-
Product
Digital Input Board
VME-1182A
-
A multifunctional intelligent controller allows COS, SOE, pulse accumulation, debounce times and time tagging control on a per-channel basis.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
-
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
783732-01
-
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
REM-11100, 2-, 3-, 4-Wire, 4-Channel Voltage Input Module for Remote I/O
784748-01
-
2-, 3-, 4-Wire, 4-Channel Voltage Input Module for Remote I/O - The REM‑11100 is a voltage input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11100 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. This module features 2‑, 3‑, and 4‑wire spring terminal connection methods, a built-in power supply for sensors, four selectable input ranges, and simultaneous sampling.
-
Product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-01
-
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
Product
NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module
786999-01
-
6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.
-
Product
PXIe-4305, 24-Bit, 32-Channel, 51.2 kS/s, 42 V, PXI Analog Input Module
783868-01
-
24-Bit, 32-Channel, 51.2 kS/s, 42 V, PXI Analog Input Module—The PXIe‑4305 is a filtered analog input module for higher voltage measurements. The module offers the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.
-
Product
NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783311-01
-
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.
-
Product
12DI/6DO IoT Modbus/SNMP/MQTT Ethernet Remote I/O
ADAM-6050
-
12ch digital input(counter)/6ch digital output(pulse output)Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful API,ASCIIGCL to perform basic logic control rulesPeer-to-Peer function to map I/O statusCloud access: Data update to AzureBuilt-in web serverWatchdog timer to recover the system
-
Product
C Series Universal Analog Input Module
-
The C Series Universal Analog Input Module helps you perform multi-purpose measurements. This module includes built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. You also can choose options to measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors.The C Series Universal Analog Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
USB-TC01, 1-Channel Temperature Input Device
781314-02
-
The USB‑TC01 is a thermocouple measurement device featuring InstantDAQ technology. InstantDAQ technology includes built-in software for viewing and logging data that automatically loads when you plug in the device, so you can instantly take … temperature measurements with your PC. You can connect the USB‑TC01 to any USB port to use your PC as a display and monitor data in real time. The USB‑TC01 is compatible with J, K, R, S, T, N, E, and B thermocouples.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
-
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
NI-9235, 10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module
785995-01
-
10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9235 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9235 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
785259-01
-
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
Product
NI-9227, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module
781099-02
-
50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The NI‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the NI‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
-
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.