Transformer
transfers of electricity from one circuit to another by electro-magnetic induction.
See Also: Transformer Testers, Power Distribution, Coil
-
Product
Transformer Ratio Meters
Three Phase Transformer Ratio Meter Standard Series
-
TRT is based on state-of-the-art technology, using the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
Product
Transformer Winding Resistance Meter
10A
-
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
Product
Current Transformer
LTTJ
-
Love Controls LTTJ Series Current Transformers allow easy monitoring of the current flowing to your load. This easy to use device provides a 0 to 10 VDC signal into both low and high impedance circuits, and is easily scalable to your needs
-
Product
Zero Phase Current Transformer
MZL-45
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Split-core type for measuring zero phase current
-
Product
ANSI Relaying Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
OIP TYPE VOLTAGE TRANSFORMER
-
12kV - 145kV post type voltage transformers having Oil Impregnated Paper( OIP) as major insulation has been designed with several unique features.OIP insulated outdoor products are subjected to extreme climatic conditions and hence extra care is taken in the design and manufacturing of such transformers.
-
Product
Transformer Ratio Meters / TRM-11
TRM-11
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fully automatic: No manual balancing. Automatic measure transformer group. Automatic calculation of ratio error.
-
Product
Instrument Transformer Calibrators
MRL 11
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
Product
Power Transformer Automatic Test Device
XD71
-
Hangzhou Xihu Electronic Institute
The device is used for power transformer power outage routine test items to do automated testing.Which is characterized by dielectric loss, insulation resistance, DC resistance, tap-changer switching characteristics, short circuit impedance and variable ratio of six test items are concentrated in an instrument,so that the instrument function, test power and test lead height fusion.Field test, just start wiring once, at the end of unplugging wiring once,the middle process by the test personnel in the computer terminal to send command control,the test system automatically completes all or part of the above test items.
-
Product
Manually Operated Transformer Oil Test Set
-
We offer Manually operated Transformer Oil Testing Kits to check the DI-electric strength of the insulating Oils as per relevant specifications via. IS 6972. It is a useful equipment for transformer / switchgear manufacturing units. Oil frittering agencies, repair shop and electrical maintenance departments.
-
Product
Portable Three Phase Transformer
-
Supreme Instrument Laboratories
Portable 3 phase double wound transformers both step-up & step-down, natural air cooled construction, housed in well ventilated sheet steel cabinet duly powder coated. All the input and output terminals are brought out and terminated on highly insulated bakelite panels duly marked for easy connection. Necessary carrying handles and castor wheel will be provided for portability.
-
Product
Differential Transformer Type Extensometers
DT Series
-
ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.
-
Product
Digital Transformer BDV Oil Test Set
-
We are engaged in manufacturing, supplying and trading an exhaustive range of High Voltage Oil Test Set, which is developed under the constant supervision of our team of experts. This equipment is acknowledged for its optimality in performance and quality.
-
Product
8-Gas On-Line Transformer Gas Analyser
TRANSFIX
-
The TRANSFIX is an 8-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.
-
Product
Transformer Test
-
Beijing GFUVE Electronics Co.,Ltd.
Check whether the performance of the transformer meets the requirements of relevant regulations and technical standards.
-
Product
LCR METER/Transformer Test
-
A type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component.
-
Product
Phase Shifting Transformer
-
Supreme Instrument Laboratories
Supreme make PHASE SHIFTING TRANSFORMERS are special transformers which provide convenient means to adjust phase angle (power factor) of A.C. loading circuit while testing power factor sensitive device for the full 90 degree LAG through '0' degree to 90 degree LEAD. Based on their rating these Phase shifters are manufactured in two configuration.
-
Product
MOTORIZED TRANSFORMER/RECTIFIER ASSEMBLY, 0-250 VDC, 200 A OUTPUT
18534PS1
-
Input power is 380 VAC, 3 PH, 50 Hz, P/N 18534PS1Output is 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDCIndoor enclosure, 50"H x 46"W x 36"DOutput voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure
-
Product
MOTORIZED VARIABLE TRANSFORMER CONTROLLED POWER SUPPLY
-
Motorized Variable Transformer Controlled Power Supply, P/N 18534PSInput: 460 VAC, 3 PH, 60 HzOutput: 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDC.Indoor enclosure.Output voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure
-
Product
Transformer Performance Tester
JYM
-
JYM insulation resistance tester is used for on-site insulation resistance measurement. The instrument has built-in positive and negative bipolar high-voltage power supplies, with large output power and strong load capacity. It is suitable for insulation resistance measurement of samples with large capacitance, such as power transformers and cables.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
Complete Transformer Test Bench
-
Weshine Electric Manufacturing Co., Ltd
Our multifunction Transformer Test Bench (VS-ZHSY Series) is intuitive with all of the ease of working with individual, dedicated instruments. We deliver this experience through our design philosophy. Rather than producing a single, complex system with afterthought towards rendering it friendly, we uniquely combine several intelligent instruments packaged as a single system.
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Split type AC Current Transformer
CTS-400
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*5A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy to install by metal fitting.
-
Product
Power Transformer
-
Transformer turn ratio meter is special designed for power transformer (single phase & three phases) and instrument transformer testing, suitable for testing in substation, transformer manufacturer, meter manufacturer. It helps to detect faulty transformer winding and tap changer position. It’s fully automatic device, can recognizes winding connection and vector group number of transformer winding. The user only need connect measuring cable and press start button and come out the test result.
-
Product
High-Speed Transformer Test System
DU-7211
-
Delta United Instrument Co., Ltd.
Inductance, Q factor, Leakage Inductance, AC Resistance, Capacitance, DC Resistance, Balance,Turn ratio, Open/Short check
-
Product
Transformer Test Equipment
-
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
Product
2 Channels, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTB
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
Automatic Transformer Winding Resistance Meter 25A
ATWRM-25
-
The Eltel ATWRM-25 with its latest " State of the art" design is an unmatched high performance of winding resistance measurement providing fast measurements, wide continuous test current ranges, high accuracy and is ideally suited for low resistance measurements both in the laboratory and in HV switchyards.