Filter Results By:
Products
Applications
Manufacturers
ICP Microphones
measure acoustic frequency, time and noise levels.
-
product
Digital ICP® - USB Signal Conditioner
The Digital ICP®-USB Signal Conditioner, Model 485B39, offers plug-and-play connectivity for your measurements. Model 485B39 from The Modal Shop, a wholly owned subsidiary of PCB Piezotronics, is a pocket-sized, dual-channel ICP to USB digital signal conditioner. The unit provides any ICP sensor – accelerometers, microphones, impact hammers, laser tachometers, and more – with a digital USB output. It is truly plug-and-play, with no drivers required. Digital ICP features two BNC inputs and a 24-bit USB digital signal output, allowing a direct connection from the sensor to any PC, tablet, or smartphone device for easy data collection, analysis, and sharing on-the-go.
-
product
ICP Microphone System
378A14
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
ICP Microphone System
HT378B02
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
product
ICP Microphone System
378C01
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
product
ICP Microphone System
378C10
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
Microphone Preamplifier
426A11
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
product
ICP Electret Array Microphone
130A23
Nominal Microphone Diameter: 1/4" Frequency Response Characteristic (at 0 incidence)Free-FieldInherent Noise (A Weighted)<30 dB(A) re 20 Pa<30 dB(A) re 20 Pa Dynamic Range (High)150Environmental Temperature Range ( Temperature Effect on Output (-10 to +50 C)<0.7 dB<0.7 dB[2] Influence of Axial Vibration Excitation Voltage 18 to 30 VDC18 to 30 VDC
-
product
Measurement Microphones
SCM
The SCM measurement microphone is a robust, free- field microphone designed for the rigorous environment of a production line without compromising the accuracy, precision, and stability required for R&D.
-
product
Outdoor Microphones
Is a measurement microphone for all-weather conditions designed for use with sound level meters.
-
product
Measurement Microphones
The microphone bodies contain the preamplifier. They combine high dynamic range and wide frequency range with low noise. These measurement microphones connect via the ASD Cable to the XL2 Audio and Acoustic Analyzer, e.g. for measurements at remote locations or to reduce acoustic reflections.
-
product
Microphones
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
product
Microphone System
378B02
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
Microphone Preamplifier
HT426E01
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
product
Microphone Preamplifier
426E01
Nominal Microphone Diameter: 1/2 Gain -0.05 dBFrequency Response (0.1 dB) (re 1 kHz)6.3 to 125000 HzFrequency Response (-3 dB) (re1 kHz) Phase Linearity (<1 )32 to 20000 Electrical Noise (A-weight)<2.8 V<2.8 V[1] Output Slew Rate 2 V/S[2]
-
product
Microphone Preamplifier
426B31
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
product
In-line ICP® Charge Converters
In-line ICP® charge converters play a vital role in converting high impedance charge mode piezoelectric sensor signals into low impedance voltage signals, facilitating input to readout, recording, and analysis instruments. Specifically engineered for compatibility with high temperature piezoelectric sensors, these units are capable of operation in environments reaching up to 500°F (260°C). The series boasts ±2.5V or ±5.0 V output, offering a range of gain options, all packaged within a compact and durable casing. As a cost-effective alternative to laboratory charge amplifiers, in-line ICP® charge converters present an appealing choice for multi-channel applications.
-
product
Measurement Microphone Cartridges
G.R.A.S. Sound & Vibration A/S
Measurement microphones are available in many types covering various frequency ranges, dynamic ranges and application situations. Selecting a microphone involves a number of choices, which can be summarized as:
-
product
Microphone Interfaces
MEMS
Listen offers 2 MEMS digital microphone measurement interfaces from Portland Tool & Die, the laboratory-grade DCC-1448 and the low cost PQC-3048 for production line use.
-
product
Measurement Microphone System
MK224SYS
The MK224SYS Type 1 measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 8 Hz to 18 kHz response, 50 mV/Pa sensitivity and a "A" weighted noise floor less than 14 dBA.
-
product
Low Light USB Camera With Microphone
Conversa
Conversa, camera for conversation (See3CAM_CU38), is a 3.4 MP low light USB 3.1 Gen1 camera with built-in stereo microphone providing 16bit audio @48KHz. This low-light USB camera is the next advanced version of our flagship product See3CAM_CU30, with built-in stereo microphone for crystal clear sound. It is a plug-and-play (UVC and UAC) compliant USB 3.1 Gen1 SuperSpeed camera and is also backward compatible with USB 2.0 host ports. It has S-mount (M12) lens holder which allows customers to choose and use the lens according to their requirement. It has a dedicated, high-performance Image Signal Processor chip (ISP) that performs all the Auto functions (Auto White Balance, Auto Exposure control).
-
product
Low Outgassing ICP® Accelerometers
Low Outgassing ICP® (IEPE) Accelerometer Types & Their Applications.
-
product
Measuring Microphone
AWA14400
Hangzhou Aihua Instruments Co., Ltd.
*Precision acoustic measurements*Pressure variation measurements
-
product
HEAD artificial head microphones
HSU III
The HEAD-Shoulder-Unit HSU III is an artificial head microphone for binaural recordings.
-
product
Reusable ICP® Strain Gauge
This high-resolution dynamic alternative to bond foil strain gauges uses a quartz sensing element in a durable, titanium housing. It has 0.0006 microstrain resolution, 5 volt output, 100k Hz frequency response and 0.5 gram mass for lightweight test articles. The reusable sensor comes with a calibration certificate, attaches to the test specimen in 60 seconds and is removed in 10 seconds.
-
product
ICP Electret Surface Microphone
130B40
Low-profile surface pressure microphone and preamp, prepolarized
-
product
For accurate testing of headphones, microphones telephones and loudspeakers
Artificial Mouths, Ears, and Couplers
Listen supplies artificial mouths, ears and ear couplers from Brüel and Kjær, GRAS and more.
-
product
Microphones & Accessories
Applied Research and Technolgy
Creative choices for recording, and USB mics for content creators.
-
product
Measurement Microphones
All microphones are omni-directional and 48V phantom powered. The XL2 Analyzer microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the XL2 automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
-
product
Phantom Powered Measurement Microphone System
7052PH
The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).
-
product
Microphone Measurement Capsule
TG MM1W
Interchangeable measurement microphone capsule for TG 1000 handheld transmittersTo calibrate ELA and PA systems in the theatre, at live concerts or at festivals