ICP Microphones
measure acoustic frequency, time and noise levels.
-
Product
Digital ICP® - USB Signal Conditioner
-
The Digital ICP®-USB Signal Conditioner, Model 485B39, offers plug-and-play connectivity for your measurements. Model 485B39 from The Modal Shop, a wholly owned subsidiary of PCB Piezotronics, is a pocket-sized, dual-channel ICP to USB digital signal conditioner. The unit provides any ICP sensor – accelerometers, microphones, impact hammers, laser tachometers, and more – with a digital USB output. It is truly plug-and-play, with no drivers required. Digital ICP features two BNC inputs and a 24-bit USB digital signal output, allowing a direct connection from the sensor to any PC, tablet, or smartphone device for easy data collection, analysis, and sharing on-the-go.
-
Product
ICP Microphone System
378C01
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
ICP Microphone System
HT378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
ICP Microphone System
378A14
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
PROBE MICROPHONE ICP
377B26
-
Open Circuit Sensitivity (at 250 Hz)Frequency Range (+2.2/-4.9 dB)2 to 20000 HzLower Limiting Frequency (-3 dB)Inherent Noise<45 dB(A) re 20 Pa Dynamic Range(3% Distortion Limit)EnvironmentalTemperature Range (Operating)-40 to +158 F-40 to +70 C[5]
-
Product
Microphone System
378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
MEMS Microphones
-
A MEMS microphone is an electro-acoustic transducer housing a sensor (MEMS) and an application-specific integrated circuit (ASIC) in a single package.
-
Product
ICP Plasma System
-
The AXIC IsoLok® Inductively Coupled Plasma (ICP) Load-Locked Processing System from AXIC, Inc. defines a new concept in Deep Reactive Ion Etch (DRIE) and low temperature-low damage Plasma Enhanced Chemical Vapor Deposition (ICP-PECVD) plasma processing. The system is based on a modular design starting with a universal chamber and cabinet unit with ICP etch or deposition bottom electrodes available for easy installation into the chamber unit combined with a load-lock. We are confident you will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma product in the market.
-
Product
Outdoor Microphones
-
Is a measurement microphone for all-weather conditions designed for use with sound level meters.
-
Product
Measurement Microphone
UMM-6 USB
-
Precision condenser microphone for critical measurement and recording applicationsConnects to your PC or Mac via USB portTrue omnidirectional pattern with calibrated flat frequency responseRugged construction with high-quality componentsCompact design; includes sturdy carrying case with foam insertCompatible with most industry-standard measurement software
-
Product
Microphone Arrays
-
One of the most important parts of an Acoustic Camera is the microphone array. It determines the spatial distribution of the acoustic microphones and therefore measurement performance of the whole system. In order to achieve the maximum possible performance in any given application, we offer a wide variety of microphone arrays. No matter if the measurement is beamforming, intensity or holography ... we have the right microphone array. For special applications we can design and build custom made microphone arrays according to the requirements of the application.
-
Product
Microphones
-
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
Product
Microphones & Accessories
-
Applied Research and Technolgy
Creative choices for recording, and USB mics for content creators.
-
Product
Quartz ICP® Links
-
Link-style sensors measure dynamic compression and tension. They are constructed using a force ring that is under compressive pre-load between threaded mounting hardware. The threaded mounting on both ends of the sensor supports integrated link-style installations. Versions offering full-scale measurements of 10 lb to 50k lb (45 N to 220k N) compression and 30k lb (130k N) tension are available.
-
Product
Industrial ICP® Strain Sensors
-
For Process Monitoring/Quality Control. The Industrial ICP® Strain Sensors incorporate piezoelectric quartz sensing crystals that respond to a longitudinal change in distance. The resultant strain measurand is an indirect measurement of stress forces acting along the structure to which the sensor is mounted. As such, these devices can provide insight into the behavior of mechanical systems or processes that generate an associated machinery reaction.
-
Product
23KHZ Reference Measurement Microphone
M23R
-
The M23R is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
ICP® Shock Accelerometers
-
Piezoelectric ICP® accelerometers afford a very high signal output (+/- 5 volts full scale) and the ease of two-wire electrical connectivity. Their inherent ruggedness enables them to be severely over ranged without damage. The addition of internal mechanical isolation minimizes the high frequency stress that would otherwise be encountered by their ceramic sensing elements. This mechanical isolation, coupled with an internal 2-pole electrical filter, built into the ICP® circuitry, tailors the overall accelerometer response to assure data quality to frequencies as high as 10 kHz. Depending on the specific model, accelerations in excess of 50 kg can be successfully measured. These modern designs, with their internal elastomeric isolation materials are verified through calibration to remain dynamically linear and are enabling piezoelectric accelerometers to operate in increasingly severe acceleration environments.
-
Product
Low Noise Prepolarized Microphone
378A04
-
The 378A04 is a matched system that is comprised of a high sensitivity microphone and a low noise preamplifier that contains a built-in filter that enables the free-field response to remain flat over a wide frequency range. The system requires a minimum of 4 mA and measures to 6.5 dBA (5.5 dBA typical) within a cost efficient, prepolarized (0V) design. PCB's model 378A04, the industry's first prepolarized low noise microphone and preamplifier system allows you to measure extremely low amplitudes. In the past this was only possible with externally polarized solutions. With a typical noise floor of 5.5dBA, this microphone system delivers all of the benefits commonly associated with prepolarized systems.
-
Product
Precision Condenser Microphone
2575
-
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Product
Microphone Preamps
-
Applied Research and Technolgy
Unlock your mic's full potential with advanced features like variable impedance, mid-side processing, and real tube warmth.
-
Product
Quartz ICP® Force Rings
-
Ring-style sensor configurations measure dynamic compression. Tension measurements are also possible if the unit has been installed with proper pre-load. The through-hole mounting supports platform, integrated link, and support style installations using either a through-bolt or the supplied stud.
-
Product
USB Microphones
-
Easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic Is esignals with the highest quality.
-
Product
Microphone Preamplifier
HT426E01
-
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
Product
Directional Microphone
MI-8100
-
MI-8100 is a shotgun type directional microphone which sharply catches the intended sound. This directional microphone is helpful for the removal of background noise in the simple sound source exploration and in abnormal sound detection. Flat frequency characteristic from 50 Hz to 20 kHz and sharp detection with high S/N ratio provide high sensitive detection of various sound coming from the specific direction. By combining the acoustic vibration monitor BL-1100, only the intended frequency or sound is focused and caught clearer.
-
Product
Measurement Microphone System
MK224SYS
-
The MK224SYS Type 1 measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 8 Hz to 18 kHz response, 50 mV/Pa sensitivity and a "A" weighted noise floor less than 14 dBA.
-
Product
30KHZ Measurement Microphone
M30
-
Used on countless full-scale concert tours, as well as in scientific research laboratories, tropical rainforests, and rocket testing facilities, the M30 has proven to be a lab-grade audio instrument that can handle any environment.
-
Product
Precision Condenser Microphone
377B11
-
Performance:Nominal Microphone Diameter:1/2 CharacteristicPressureOpen Circuit Sensitivity: 50 mV/Pa50 mV/PaInherent Noise<15 dB(A) re 20 Pa<15 dB(A) re 20 Pa Dynamic Range (3% Distortion Limit)>143 dB re 20 Pa>143 dB re 20 Pa EnvironmentalTemperature Range (Operating)-40 to +248 F-40 to +120 C Temperature Coefficient of Sensitivity (+14 to +122F (-10 to +50C))0.005 dB/F0.009 dB/C