Display Calibration
reference a test pattern to adjust by.
See Also: Calibration, Calibrators, Power Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
Online Conductivity Controller
LD-LOCC-A10
-
Online Conductivity ControllerLD-LOCC-A10features 3 points conductivity calibration system, TDS measurement mode, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, Temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. This controller measures Conductivity and TDS values in µS/ cm, and mS/ cm units.
-
Product
Display Color Analyzer
Model 7123
Analyzer
Luminance and chromaticity measurement of Color Display0.005 cd/m2low luminance measurement (A712301)Wide luminance range: 0.0001 to 25,000 cd/m2 (A712301) 0.01 to 200,000 cd/m2 (A712302)High accuracy measurementMaximum 9 display modes: xyY, TΔuvY, u’ v’ Y, RGB, XYZ, Contrast, ProgramAble to control Video Pattern Generator and UUT (Unit Under Test)Built-in contrast measurement function to calculate the contrast ratio directlyEquipped with programmable test items that can complete the planned tests with one single buttonSupport USB flash disk that can copy the test procedures to other station for useJudgment function embedded to judge the test result automatically with one single buttonCalibration period setting and reminding functionMemory for storing 100 channels of standard color data and calibration dataBuilt-in flat display calibration data LCD-D65 & LED-D65* to be applied for chromaticity measurement instantlyOptional display white balance alignment system can be used to integrate all optical test stations to one single station
-
Product
Wavelength and Power Meter
WPM-1NM
-
•Wide range Wavelength Meter– Auto λ detection from 1270nm to 1610nm– Auto power calibration & display•FTTx/PON Wavelength Meter– 1310/1490/1550nm auto λ detection– Auto power calibration & display•Optical Power Measurement– Optical network power measurement– Power measurement for system & module•Insertion Loss Measurement– Optical network & component IL measurement– IL measurement for CWDM 16-wavelength•Smartphone Interface– Communicates with smartphone via bluetooth– Smartphone application software
-
Product
Online pH Controller
LD-LOPC-A10
-
Online pH ControllerLD-LOPC-A10features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.
-
Product
XYZ Color Sensor
AS7261
-
Calibrated XYZ color sensor provides complete, integrated platform for handheld color analyzers, color calibration and mobile analysis devices. Tri-stimulus XYZ realized by silicon interference filters. UART or I²C slave digital Interface. 16-bit ADC with digital access. Programmable LED drivers. 20-pin LGA package 4.5mm x 4.7mm x 2.5mm, with built-in aperture. Compact true-color sensing. Applications; Color/CCT sensing, Fluid or reagent analysis, Color point comparison, Display calibration.
-
Product
Nonlinear Component Characterization 10 MHz - 110 GHz
S94510B
-
Measure and display the calibrated, vector corrected waveform of the incident, reflected, and transmitted waves of the DUT
-
Product
Counters and Timers
-
Orbit Controls counters and timers are designed for connection to practically all industrial sensors and pulse sources . They can be used as process monitors to display the process variable to be measured or as process controllers for control and monitoring tasks. The devices display and process pulses and frequencies, as well as quadrature signals from incremental and absolute encoded rotary encoders. In addition to information on the display, the devices also generate data and analog outputs and monitor preselected limit values. The process parameters are entered via the keyboard so that the display is calibrated in the required units and the output signals, serial interfaces and limit values are optimized.
-
Product
Handheld Water Quality Meters
LAQUA PC210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Measuring Management
-
Our test equipment is more than a test-set with a screen. Our application software provides an integrated tool to easily store the measurements at different stages and create a log of what we have done. Each measurement stores all data and settings, including display, markers and calibration.
-
Product
Color Test Charts
-
Shenzhen ThreeNH Technology Co., Ltd.
3NH color test charts provide accurate color calibration and image consistency across devices. They are Ideal for cameras, printers, and scanners. These charts meet international standards, helping professionals achieve precise color reproduction in photography, printing, and display calibration workflows.
-
Product
Handheld Water Quality Meters
LAQUA PC220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Online Dissolved Oxygen Controller
LD-LODC-A10
-
Online Dissolved Oxygen ControllerLD-LODC-A10features 1 to 2 points dissolved oxygen calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. It measures the amount of dissolved oxygen in mg/l, ppm units or in % of saturation. The accuracy of measurement is improved by manual salinity and barometric pressure compensation mode.
-
Product
15-meter (49 feet) Sensor Cable
E1739C
Calibration Cable
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
CalPod Drive Cable, 40 GHz, 2 Meter
85553A
Calibration Cable
This cable provides the bias voltages and control signals for operation of the 40 GHz CalPod modules. This cable is supplied with the 85540/41/42A CalPod modules.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
Mechanical Calibration Kit
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
Calibration Cable
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Calibration Short For Digital Multimeters
34172B
Calibration Short
The Keysight 34172B digital multimeter calibration short is a set of two shorts which provide a convenient and reliable method to apply a short to the input connectors of the multimeter. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals.
-
Product
Electronic Calibration Module (ECal), 26.5 GHz, 3.5 Mm, 2-port
N4691D
Electronic Calibration Module
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
Mechanical Calibration Kit
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
Electronic Calibration Module
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
Electronic Calibration Module
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
Diagonal Measurement Kit
10768A
Mechanical Calibration Kit
The Keysight 10768A Diagonal Measurement Kit is designed for use with the Keysight 5530 Laser Calibration System. It allows linear measurements to be made on the four body diagonals of a machine tool's working volume. These measurements document the machine's capability and quickly perform a complete check of volumetric positioning performance. In addition, long-term drift tests can be performed over hours or days, showing possible effects of temperature on geometry.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
Electronic Calibration Module
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Electronic Calibration Module (ECal), 40 GHz, 2.92 Mm, 2-port
N4692D
Electronic Calibration Module
The Keysight N4692D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4692D is a precision 2-port ECal module that supports 2.92 mm connectors up to 40 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4692D is included for securing your ECal module and accessories.
-
Product
7-Meter Laser Head Cable
10882B
Calibration Cable
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz, Type-N(m), 50 Ohm
85514A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
Product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
Electronic Calibration Module
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
Mechanical Calibration Kit
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.