Temperature
a measurement of heat or cold.
-
Product
Biased and Unbiased HAST Testing
-
Considered within the semiconductor industry as the fast and effective alternative to Temperature Humidity Bias testing (THB), Highly-Accelerated Temperature and Humidity Stress Test (HAST) is a critical part of the device package Qualification process and is used to evaluate the reliability of non-hermetic packaged devices in humid environments.
-
Product
Wet-Well Calibrators
-
Electronic Development Labs, Inc.
A device used for high-accuracy temperature calibration of various sensors.
-
Product
On-line FT-NIR Analysis
MATRIX-F
-
The advantages of real time, on-line FT-NIR analysis have been well established. However, conventional spectrometers can only be installed close to the process that they are monitoring, which makes the analyzer be exposed to a hostile environment, like drastic temperature changes and exposure to dust and dirt. Furthermore, the instrument needs to be positioned in hard-to-access and often Ex-protected area.
-
Product
Walk Through Metal Detectors
VAT 620-CO2 VAT 622-CO2 VAT 63
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
It can control the indoor co2 ,temperature and humidity through detection with analog output or switch.
-
Product
DC/AC Inverter 450 W
ODS-750-7281-T
-
DC/AC inverter with 450 W from Premium | input ranges from 9.5 - 15 VDC | output is 120 VAC | operates in temperatures from -25 to +70 °C | approved for EN45545-2 fire and smoke | railway version
-
Product
Flashlight Solar Simulator
-
Flashlight Solar Simulators have the advantage of negligible temperature change to the solar cell. For this reason, they are primarily used in cell and module production environments. Also, they are a more budgetary alternative if large cell areas are to be illuminated, because it is easier to have excellent light uniformity on areas of 8 in x 8 in or larger. So, this type of solar simulator is also used for analysis of large area thin film solar cells. But care must be taken, as some materials (e.g. CIGS) have long inherent time constants, so that the pulse length (better: flash plateau) must be chosen accordingly.
-
Product
Hardness & LSI Titration Kit
Ultrameter™ III 9PTKB
-
The Ultrameter III 9P™ AHL Titration Kit, is based on the tried and tested design of the Ultrameter II™. The 9P adds the ability to perform in-cell alkalinity and hardness titrations either as stand-alone measurements or as part of an LSI calculation. Alkalinity, hardness, pH and temperature values can be manipulated in the LSI calculator to predict the effect of changes on water balance. Measurements are extremely accurate. And the 9P is simple to operate and maintain.
-
Product
Pico-ITX SBC With 7th Gen Intel® Core™ I7/i5/i3 & Celeron® Processor, HDMI/LVDS And LAN
PICO512
-
The PICO512 is designed to support the latest 7th generation Intel® Core™ processor or Celeron® processor 3965U. Coming with one 260-pin DDR4-2133 SO-DIMM socket supporting system memory up to 16 GB, the Pico-ITX motherboard also features a PCI Express Mini Card slot in support of mSATA and a pair of expansion connectors for an additional I/O board/signals. It supports a 4K visual experience with dual display outputs through HDMI and LVDS. Pico-ITX SBC can withstand a wide operating temperature range from -20°C to +70°C.
-
Product
Thermal Sensitivity Tester
NTE-2A
-
The NTE-2A Thermal Probe is a sophisticated, non-invasive device for the clinical evaluation of neuropathy and the assessment of short fiber neurological function. Individual thresholds are compared to normals to statistical normals. These results provide an accurate means of tracking chronic changes in small fiber nerve function. It can be used for pain studies and in any application were a variable, accurately-controlled temperature stimulus is required. The NTE-2A is often used in conjunction with the Vibratron II to assess peripheral neuropathies.
-
Product
6U Switch Board
VP68801
-
LinkedHope Intelligent Technologies Co.,Ltd.
VP68801 is a China local design VPX Switch, compliant with VITA46.0, VITA48, and VITA65 specifications. The Profile of VP68801 is SLT6-SWH-16U20F-10.4.2, which uses Gb Ethernet as control plane and SRIO as data plane. It is mainly applicable to high-speed data exchange and routing among different types of payload boards in a VPX chassis. The switching board is designed as 6U VPX form factor, supporting both traditional air-cooled version and conduction-cooled version. With reliable anti-shock and vibration capability, excellent heat dissipation performance and unique environment protection design, the whole board can be stably operated in the wide temperature environment of -40°C to +85°C.
-
Product
Temperature Indicators
-
Thermometers of displacement of the hand 90˚Mb 72 20 - 1000˚ / J /Mb.
-
Product
General Purpose Surface Temperature Assembly
S2-2
-
The Series S2-2 General Purpose Surface Temperature Assembly is ideal for monitoring the temperature of indoor distribution lines when it is not possible to penetrate the pipe. The plastic housing is in the shape of a standard junction box with multiple knockouts for easy conduit access. The strap-on connection quickly wraps around a pipe and can be securely tightened using a flat head screw driver. The Series S2-2 can be ordered with a choice of 11 output options that allow it to communicate to any standard building control system
-
Product
Wireless sensors for humidity
-
The wireless transmitters in the EE240 series combine state-of-the-art sensor technology with excellent transmission reliability. Installing the wireless measurement system is very easy and one network can contain up to 500 transmitters. Wireless transmitters EE244 and EE245 are ideally suited for wireless, high-quality measurement of humidity and temperature.
-
Product
Digital Thermometer
TH310
-
The Milwaukee TH310 compact digital thermometer is specifically designed to help professionals and home owners regulate their home brew, wine process, classroom experminents or labs duties. Keeping the proper temperature improves results of beer and wine output. It also helps in understanding the quality of lab data. Keep temperature in your target range for better results.
-
Product
Configurable System For Temperature Measurement With CAN Interface
MU thermocouple1 CAN
-
The thermocouple measuring unit offers connections for 8 thermocouples, which are designed for the temperature measuring ranges J, K or T, depending on the product version.
-
Product
Current Data Logger Two Channels with USB
VA602-A1-A1
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Two tunnel data logger with voltage current temperature (thermocouple) K.J.PT type, with USB, up to 16000 data record point.
-
Product
Data Panel
ІТ-09Т
-
Display of measurement results of ambient dose equivalent rate(DER) of gamma radiation obtained from the BDBG-09 detecting unit of gamma radiation; Real time display; Air temperature display; Audio and light alarm when threshold levels of gamma radiation DER exceeded.
-
Product
Automatic Titrator
-
Large color TFT-LCD with a touch panel (8.4-inch) enables easy key entry.Up to 4 titrators, MKV-710B Volumetric, MKC-710B Coulometric or MKH-710/2nd Hybrid Karl Fischer moisture titrators or additional AT-710B potentiometric titrators, can be connected and simultaneous measurement is possible.Monitoring temperature during titration ensures safe measurements.
-
Product
Fully Automatic Solar Cell
Module Laminator-H
-
1. Model: BSL2236OAC-H2. Effective lamination area: 2200mm × 3600mm3. Dimensions: length 17410mm × width 3665mm × height 2164mm4. Heating method: heat conduction oil heating5. Compressed air source pressure: 0.6~0.8MPa6. Working vacuum degree: 100~40Pa7. Evacuation rate: 70L/S8. Temperature control accuracy: ±1.5°C9. Temperature control range: room temperature - 180°C10. Temperature uniformity: effective lamination area≤±2℃11. Lamination chamber height: 30mm12. Evacuation time: depending on the process, it is recommended to take 5 to 8 minutes13. Upper cover stroke: 300mm
-
Product
Temperature and Humidity Duct Mount Transmitter
T3413D
-
Relative humidity, temperature sensors at 150mm stem. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Environmental Chamber
REXMED REC-200
-
MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
Temperature Calibration System
-
Thermal Engineering Associates, Inc.
Systems for determining relationship between temperature-sensing junction voltage versus junction temperature of diodes, integrated circuits and thermal test die. Provides internal current sources, voltage measurement to 1 mV, and temperature measurement to 0.1ºC. 16-channel capability with optional printer and serial port data output.
-
Product
Immersion Temperature Probe
U1181A
Temperature Probe
Measure the temperature of food, oil, and other liquids within the range of -50°C to 700°C.
-
Product
Rectifier/Modular PSUS
-
Electronic Test & Power Systems
A compact range of single and multiple output AC/DC power supplies are also available. These fixed output power supplies operate at up to 55°C without derating. For harsh environments extended temperature ranges of -40°C to +70°C can be specified.
-
Product
Digital Humidity & Temperature Meter
DL7102
-
A compact probe size, with combined humidity and temperature meter.Ideal for field use offering high accuracy and fast response measurement.The addition of dew point and wet bulb reading makes this a truly versatile instrument.
-
Product
Gain Blocks
-
Analog Devices RF amplifiers are designed utilizing the company’s leading amplifier and RF IC expertise. Our extensive family of single-ended input/output, fixed-gain amplifiers can be used from dc to microwave and include gain blocks, low noise amplifiers, intermediate frequency amplifiers, driver amplifiers, and differential amplifiers. These devices offer high linearity, low noise figures, and various fixed-gain options, as well as low power consumption; they are all fully specified over frequency, temperature, and supply voltage for use in a variety of applications.
-
Product
Hopper Ash Level Thermocouple System
HALT
-
The Hopper Ash Level Thermocouple (HALT) System is a preventative maintenance and safety tool that continually monitors the levels of ash within a hopper. As the hopper plugs and the ash levels increase, the thermocouples will become insulated from the boiler heat by the ash. Low temperature readings trigger visual and digital alarms which indicate that the hopper has plugged.
-
Product
Boolean Logic Gates
-
Advanced Science and Novel Technology, Co., Inc.
High speed broadband Exclusive-OR (XOR) Boolean logic gateExhibits low jitter and limited temperature variation over industrial temperature rangeIdeal for high speed proof-of-concept prototypingFully differential CML input interfacesFully differential CML output interface with 400mV single-ended swingSingle +3.3V or -3.3V power supplyPower consumption: 415mWFabricated in SiGe for high performance, yield, and reliabilityCustom CQFP 24-pin package
-
Product
Chambers and Glove Boxes
-
Standard Environments: ETS' multi-purpose benchtop units for laboratory and production use are large enough to accommodate testing and fabrication, as well as storage of materials, test equipment, and assemblies, yet they are small enough to fit on a standard workbench. The systems are able to independently maintain humidity from <5% to >95% RH and temperature from -22F to 122F (-35 to 50C) when unit is placed in an ambient environment location.
-
Product
Infrared Thermometers
-
Easily measure surface temperatures with ThermoWorks non-contact IR guns, ideal for produce and agriculture inspectors, HVAC, construction, warehouse, quality assurance, HACCP and cold chain management, both shipping and receiving. Choose from fixed or adjustable emissivity; single, dual or circle laser types; and lens optics from close focus—for electronic components and laboratory measurements—to 100:1—for long distance measurements. High temperature ranges up to 3272°F (1800°C) are perfect for metallurgy and metal work foundries.





























