Infrared Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
Product
Voltage Calibrators
-
Practical Instrument Electronics, Inc.
PIE has a voltage calibrator to fit your needs from the PIE 235 voltage and pH simulator to the advanced troubleshooting capabilities of the PIE 532 milliamp and voltage calibrator. The PIE 532 includes our patented Loop Diagnostic Technology! All the voltage/milliamp calibrators have fuse-less protection, rugged design and long battery life. With the PIE 535, source 4 to 20 milliamps or 10 to 50 milliamps into loop instruments and drive final control elements such as valves and actuators with up to 42 volts.
-
Product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
-
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Multichannel Acoustic Calibrator
WK-8
-
Multichannel Acoustic Calibrator Type WK-8 is designed for calibration of multichannel acoustic measurement systems equipped with a half-inch measuring microphones in the field conditions.
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
Portable Calibration Baths
6109A / 7109A
-
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
Product
Scientifically Calibrated Audio Clips
AudioRef™
-
AudioRef is a package of scientifically calibrated audio reference clips that enable professionals to accurately set up and evaluate audio monitoring equipment.
-
Product
Infrared Thermometers
-
Two specifications tell you nearly everything you need to know about any infrared (laser) thermometer: its measurement range and its distance-to-spot (D:S) ratio. The wider the range and the higher the D:S number (a measure of its optical resolution), the better the instrument. Infrared Thermometers (IRTs) with lower numbers are perfectly adequate for simple tasks like spot-checking food temperatures and energy auditing such as the IRT207 Non-Contact Infrared Thermometer. Higher-priced infrared thermometers intended for industrial users may have a SKU that ends in "K" such as the IRT850K Ultra-Wide-Range Infrared Thermometer with K Port and Adjustable Emissivity. The "K" indicates that it can accept inputs from a "K" type thermocouple probe used to measure temperature on-contact.
-
Product
MultiFunction Calibration
-
Omega offers a large selection of configurable Multi-Channel Meters that accept a wide variety of input signals for scanning, displaying, and logging measured data from multiple sensors.
-
Product
Infrared Pyrometer with Laser Sighting
thermoMETER CTlaser
-
Pyrometers of the thermoMETER CTLaser series are used for precise, industrial measurements. Using two laser beams, the measurement spot is marked which ensures a precise temperature measurement. thermoMETER CTLaser temperature sensors are used in numerous applications. From extremely low temperatures (-50°C) to the highest temperatures (3000°C), these IR pyrometers measure precisely and reliably.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Process Calibrators
-
We offer process calibrators that are designed for the process industry applications and to be used in the demanding conditions in process industry.
-
Product
Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/P -
-
SEM1605/P - Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
-
Product
Humidity and Temperature Calibration
-
The most comprehensive temperature, humidity and dew-point calibration offering on the market today.
-
Product
Infrared Cameras
-
The stationary infrared cameras of the VarioCAM ® HD head, VarioCAM ® hr head, VarioTHERM ® InSb and PIR uc series with their solid light metal housings are suitable for fixed use under harsh process conditions.
-
Product
Calibration Management Software
MET/CAL®
-
MET/CAL software is structured around the flow of instruments through the calibration process and addresses a wide range of test and measurement instrument calibration needs, from the simple to the complex. It is based on the traditional calibration model as its framework—comparing an instrument to a standard of known uncertainty.
-
Product
Insulation Tester Calibrator
M191
-
High resistance calibrator for insulation testers up to 10 kV. Other insulation related functions include HV capacitance, short current, dielectric and polarization parameters and timer test.
-
Product
NIST Calibration for D600A-AT.
D600A-AT-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Calibration Services
-
Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).
-
Product
Kit, Cable Assembly, SH-37F-OM6/4, 9219 Calibration Cable Kit
146907-01
-
Kit, Cable Assembly, SH-37F-OM6/4, 9219 Calibration Cable Kit
-
Product
Pressure Calibrator
30
-
AMETEK Sensors, Test & Calibration
The 30 Series is a wide range digital pressure calibrator that fits easily into your shirt pocket. Its internal sensors give you 0.05% of reading accuracy and resist damage from overpressure.
-
Product
Crossover Calibrator
CC-1
-
The purpose of this tool is to enable the installer to set the crossover frequency of an electronic crossover to the desired frequency, accurately and quickly. It can also be useful for matching gains on multiple amplifier competition type systems.
-
Product
Irthermo-Anemometer With Built-In Infrared Thermometer
Model KM 730 / KM 732 / KM 733
-
Kusam Electrical Industries Limited
IRthermo-Anemometer is with built-in non-contact Infrared Thermometer. The IRthermo-Anemometer is the air velocity, air flow (volume), air temperature, and non-contact infrared temperature measuring instrument. To measure the air velocity, put the sensor head face to the measurement air. Then the first reading will show the air velocity value. To measure a temperature, point the meter at a target until the temperature is read. (Make sure the target area is larger than the unit’s spot size. For large target object ensure that you are within target distance.)
-
Product
Energy Meter Calibration
GF312D1
-
Beijing GFUVE Electronics Co.,Ltd.
The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
-
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
Conformance Calibration Standard Test Card for UPC/EAN Symbol Verifiers
AI-CCS-UPC/EAN-E Rev S
-
For those who prefer a traditional vertical format calibration test card, APPLIED IMAGE offers our new Conformance Calibration Standard Enhanced for UPC/EAN Bar Code Symbol Verifiers. The new standard complies with both the ANSI X3.182 and ISO 15416 standards and is ideal for testing of verifiers, scanners, and other UPC bar reading equipment as well as a tool for training new operators to assure proper “methodology' in the use of verifiers.
-
Product
Pressure Calibrators
-
We offer pressure calibrators as portable and as workshop models. Pressure measurement is performed with internal and/or external pressure modules for better flexibility. Pressure measurement ranges go from vacuum up to 1000 bar (14,500 Psi). Both gauge (vacuum and positive) and absolute pressure can be measured with same modules meaning you don’t need to buy so many module for greater flexibility. Also, intrinsically safe pressure calibrators are available for use in hazardous areas.
-
Product
Adaptive Infrared Imaging Spectroradiometer
AIRIS
-
The Adaptive Infrared Imaging Spectroradiometer (AIRIS) has been developed for real-time standoff detection of chemical vapors and biological aerosols as well liquids and solids (such as chemical agents and trace explosive residues) on surfaces.
-
Product
Infrared Camera for Methane and VOC Detection
FLIR GF320
-
The FLIR GF320 detects hydrocarbon and volatile organic compound (VOC) emissions from natural gas production and use. With this optical gas imaging camera, inspectors can check thousands of components and see potential gas leaks in real-time. The GF320 is lightweight, offers both a viewfinder and LCD monitor, and has direct access to controls. Embedded GPS data helps in identifying the precise location of faults and leaks, for faster repairs.
-
Product
Calibrators
-
Our high accuracy calibrators work with all competitor products and offers the customer a way to maintain their equipment, while keeping the specifications of their process.
-
Product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
-
Portable, self-contained, high-intensity acoustic microphone calibration source