RS422
One of several standards that incorporate balanced line signals into DB connectors. A pair of wires is used to carry each signal. The data is encoded and decoded as a differential voltage between the two lines. (www.sangoma.com)
See Also: Serial Communications, I2C, RS232, RS485
-
Product
8-Port Serial Interface, Modular, With/Without Optical Isolation, 3.3V/5V
APCI-7800-3
-
8-port serial interface, RS232, RS422, RS485, 20 mA CL, modular mounting
-
Product
MODEM ELIMINATOR
-
The UDC-ME allows two DTE devices (such as routers) to communicate within proximity of each other. The UDC-ME transmits data bi-directionally at clock rates of 1.2k up to 3.072Mbps between DTE devices. The unit is equipped with two interface slots that allow a host of serial interface cards to be utilized. The serial interface cards available are RS-232, RS-422/449, RS-530, X.21, V.35 and HSSI. The Serial Interface cards are interchangeable and may be mixed such as RS-232 to V.35 thus eliminating the need for an interface converter or changing expensive serial cards on a DTE device such as a router.
-
Product
Interface And Signal Processing Units
-
The interface and signal processing units extend the field of application of Micro-Epsilon sensors. The interface modules are used to convert sensor signals into digital or bus-compatible interfaces. This enables interfaces such as USB, RS422, Ethernet/IP, Profinet and EtherCAT for numerous sensors. The signal processing units are also used to record several sensor signals, to calculate and output them together. This is necessary, for example, for planarity measurement or thickness measurement.
-
Product
RS-232 to RS-422/RS-485 Interface Converter
Model 365
-
FEATURES: User Selectable RS-422 or RS-485; User Selectable 2 or 4 Wire RS-485; DataSpy® LCD Display; Intelligent Control of RS-485 Transmitter and Receiver; DTE/DCE Compatible; Data Rates Up to 115.2 KBPS. The Model 365 multimode interface converter allows operation in compliance with RS-485 or RS-422 equipment, and RS-232.
-
Product
CPCI Based 486DX4 Board
MS 1501
-
- CPCI/PXI Bus Interface, 6U form factor- Watchdog Timer- Hot Swap Facility- PCI Bus Rear IO Expansion for External Bus Interface- Debugging Monitor interface through RS232- JTAG interface for 486 for boundary scan test- Power Source through the CPCI connector J1 (±12V, +5V, 3.3V)- 1Mbytes of Dual Port RAM, 256Kbytes of STATIC RAM- 1MBytes of FLASH PROM- RS232, RS422 Serial Interface- Intel 486DX4 operating at 100MHz frequency at the core- Driver interface for Windows2000/XP/VISTA and LINUX/RT LINUX OS
-
Product
8-Port Non-Isolated RS-232/422/485 Ethernet Card
ECU-P1618D
-
enables 8 legacy serial devices to communicate over a standard LAN/Ethernet network. It supports multi-protocol operation (RS-232, RS-422, or RS-485) and acts as a gateway for data, often featuring virtual COM port redirection and high-speed data transfer.
-
Product
Isolated RS-485
-
Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications. The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus.
-
Product
Mezzanine System
5033
System
ECM P/N 5033 provides eight channels of RS485 / RS422 I/O. The 110 ohm termination for each channel is enabled or disabled in software. Disabling termination saves power by eliminating unneeded or redundant termination. Speeds of up to 20 Mega bits per second are possible, but this design also features a 250K bits per second slower edge rate mode. The 250K bit mode is valuable when EMI is more of a concern and throughput is not important. All channels power up as inputs with the outputs disabled.
-
Product
USB / RS232 / RS485 / RS422 Opto Isolators
-
USB has now moved from the desktop to more challenging environments, including instrumentation, point of sales, factory & building automation, etc. With our rugged, industrial-grade USB isolators and USB to RS232 / RS485 / RS422 optically-isolated converters, we ensure that your assets are well protected from unexpected events.
-
Product
Sixteen Port MIL-STD-1760E/HS-1760 Lab Switch
SWT-HS1760-16
-
Avionics Interface Technologies
AS5653B Compliant switch - Sixteen port non‐blocking switch with each port operational at 1.0625 Gbps - Crossbar design, with 34 Gbps total transmit and receive bandwidth - Controlled via RS-232/RS-422/RS-485 or SSH/SFTP over Ethernet - Monitor/Keyboard via VGA and USB ports - FPGA based design - Available as IP CORE
-
Product
4 Serial Communication Channels, Programmable RS-232/422/485, Isolated
SC5
-
Serial Communication Module SC5 provides up to 4 high-speed, programmable RS-232/422/485, individually isolated communication channels. Each channel is programmable for either RS-422/485 (differential, DF) or RS-232 (single ended, SE) hardware level interfaces. Individual channel isolated returns are available as part of the channel user interface signal set (for SE or ISO-GND reference).
-
Product
Serial Transceivers
-
Exar offers a complete portfolio of RS-232, RS-485 and RS-422 transceivers and the industry's largest portfolio of multiprotocol transceivers. At 52Mbps, Exar offers some of the industry's fastest RS-485 and multiprotocol transceivers.
-
Product
RS-485, RS-422 & RS-232
-
Renesas has a rich interface history dating back to the 1970s. Our RS-485, RS-422 and RS-232 transceivers are used by the biggest names in industrial process control, telecommunications, and hundreds of different applications.
-
Product
USB to RS-422/RS-485 Converter
ND-6530
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
RS-232 to RS-422 Optically Isolated Interface Converter
Model 265
-
FEATURES: Eliminates Ground Loops; 19.2 KBPS at 2 Miles;TD and RD Indicators; Use in Pairs as Double Isolated Short Haul Modems; Use in Pairs as Double Isolated Short Haul Modem. Total isolation between RS-232 based systems and RS-422. Unique circuitry allows the RS-422 port to withstand surges exceeding 10 kilovolts.
-
Product
PXI-8433, 4-Port, Isolated, RS485/RS422 PXI Serial Interface Module
779539-01
Serial Interface
4-Port, Isolated, RS485/RS422 PXI Serial Interface Module—The PXI‑8433/4 is a high-performance industrial interface for high-speed, port‑to‑port isolated communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
Smart GPIB Serial Interface Board
Model 4808
-
* Provides smart GPIB-to-serial path for serial devices with RS-232, RS-422 or RS-485 signals.* Provides all IEEE-488.2 functions and the Status Reporting Structure.* Smart firmware automatically passes GPIB data to serial device.* SCPI commands set serial configuration, GPIB address and user's IDN message.* On board voltage regulator for operation from 5 to 15 Vdc power.* Rear panel mounting eliminates cables.
-
Product
GPIB Serial Interface
Model 4894B
-
* Provides RS-232C single-ended and RS-422/RS-485 differential serial signals. * Expanded baud rate range from 50 to 115,200 baud.* 256 Kbyte RAM buffer for spooling data.* Over 600 Kbyte/second GPIB data transfer rate.*Transparent data transfer.* Programmable replacement for the NI CV interfaces.* 1 U high rack mount kit mounts one or two 4894Bs* Includes US 115 VAC Power Adapter, Manual and Support CD.
-
Product
3U CPCI ARINC 429 Board
MS 1725
-
- Bus Interface:- 32 Bit PCI Bus with 3 U Form factor- PCI to PCI Bridge Interface- Speed of operation up to 66MHz- 8 ARINC 429 TX and 16 ARINC 429 RX channels- 4 RS422 Channels- 16 TTL I/O Channels- Message Storage Buffer- Driver interface for Windows2000/XP/VISTA and LINUX OS- Self Test future
-
Product
PXIe-8431/16, 16-Port, RS485/RS422 PXI Serial Interface Module
781473-02
Serial Interface
The PXIe‑8431/16 is a high-performance interface for high-speed communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
Multi Protocol Analyzer
LE-3500R
-
LE-3500R/LE-2500R adopted TTL port as its standard besides RS-232C, RS-422, and RS-485 while having the same feature such as small and light body of LE-3500/LE-2500. You can monitor I2C or SPI without expansion board.
-
Product
Analog or Digital Communications Switching Systems with D Type Connectors
RS Series
-
The RS Series computer controlled switching systems are designed to switch multi-wire groups of signal up to 25 wires. These systems are typically used for signals such as parallel TTL, RS232, RS422, WAN or modems, but can also be used for any group of analog or digital signals having a bandpass up to 30 MHz or a data rate up to 20 Mbps.
-
Product
USB-485/4, 4-Port, USB, RS485/RS422 Serial Interface Device
778476-44
Serial Interface
The USB‑485/4 interface transforms your USB port into a single asynchronous serial port for communication with RS485 and RS422 devices. You can use a USB‑485/4 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
Firmware for High-speed Communication
OP-FW12GA
-
OP-FW12GA is the firmware to increase the speed of monitoring test of bit synchronous communication (such as HDLC/SDLC/X.25, or CC-Link communication), SPI communication, Profibus-DP (field bus known for high-speed communication), UART (asynchronous communication, which is commonly used). By processing great part of monitoring processes by FPGA, it unfailingly captures communication data with time stamps of a microsecond rate. The interface supports RS-232C/RS-422/RS-485/TTL.
-
Product
Multi Protocol Analyzer
LE-2500R
-
LE-3500R/LE-2500R adopted TTL port as its standard besides RS-232C, RS-422, and RS-485 while having the same feature such as small and light body of LE-3500/LE-2500. You can monitor I2C or SPI without expansion board.
-
Product
Sound Velocity Sensors
SVP 70
-
Compact and robust, the SVP 70 features a long path length whether you install it on a survey vessel, or take it down to 6,000 metres on an ROV, AUV or submarine.The SVP 70 is an all-titanium plug -n- play system with RESON SV processors, wide input voltage and RS232 and RS422 communication interfaces for long cable runs.
-
Product
USB To RS232 / RS485 / RS422 / TTL / Serial / Ethernet Converters
-
With our high-quality, high-performance USB to RS232 / RS485 / RS422 / TTL serial and Ethernet converters that use only top-quality chipsets such as FTDI and Silicon Labs, USB signals are converted seamlessly into RS232, RS485, RS422, TTL, serial and Ethernet signals. Pick from our menu of industrial or commercial-grade devices confidently, knowing that you will get nothing but the best from CommFront.
-
Product
DDLS 200 with 2 Mbit/s Transmission Rate
-
Leuze electronic GmbH + Co. KG
Optical data transmission for RS interfaces and fieldbuses up to 300 m and up to 2 Mbit/s. Infrared data transmission protects the DDLS 200 from interference. Systems are available for all common industrial fieldbus interfaces. The ranges are stepped and reach a maximum transmission distance of 300 m. Low ambient light sensitivity through special FSK method. Available interfaces: PROFIBUS, Interbus and CAN/DeviceNet, as well as RS422 and RS 485.
-
Product
CPCI ARM LPC3250 Board
MS 1513
-
- 32 Bit ARM LPC3250 Processor (256KB SRAM)- 133MHz External Bus Speed and 266 MHz internal CPU Speed- 32 Bit, 33MHz CPCI Bus, 6U Form Factor- External memory ( Flash – 2 MB, RAM - 512 KB, DPRAM – 128KB)- 10/100 MBPS Ethernet Interface- USB 2.0 Host/Device Interface- 2 RS232 Serial Ports, 4 RS422 Serial Ports- M Module Interface- 6U board compatible with CPCI & PXI backplanes- High Speed Logic Device- Hot Swap Feature- Front Panel and Rear IO Interface- External Bus through Rear IO- Reception of 3Kbytes within 2ms through Ethernet- Board Dimension is 160mm x 233.35mm- Power Requirements: +3.3V, +5V and +/-12V- Board Dimension is 160mm x 233.35mm- Board has Rear IO interface- Ethernet, JTAG, RS232, USB connectors at front side- BSPs and Driver software for Windows and Linux OS
-
Product
Mission Computer Software Integration Rig
MS 1124
-
The HSIR is the ground test facility and it simulates various LRUs/sensors interfaced with the HAWK Mission Computer. RIG consists of Industrial computers with Simulation modules, Acquisition modules, Video generator module and video display monitors. RIG provides the simulated inputs to both the MCs from each simulated sensor/ LRU through hardwired signals, through the MIL-1553B, Arinc 429, RS-422, RS232 and Ethernet etc. The rig is capable of testing two MCs together either of which can be used as the Bus Controller (BC) or the Remote Terminal (RT). The rig provides the facility to monitor and acquire the MIL-1553B, Arinc 429, RS-422, and RS232 Ethernet bus, Analog IOs, Synchro IOs, Discrete IOs and transactions that takes place between the MCs and various sensors/units. The RIG has the capability to test individual MCs also.