Discharge
-
Product
Online PD Spot Tester
Liona
-
Cable testing and diagnostics with the BAUR liona. Liona is a portable online PD spot tester for measuring and locating partial discharges in cables and switchgear during normal mains operation. Liona lets you test cable systems and electrical equipment online without switching off partial discharge activities, and then generate trend analyses. Even a PD spot test (duration: 5-10 minutes) is capable of reliably assessing the current status of your system.* Automatic PD detection during normal mains operation (without switching off the cable route)* With DeCIFer technology: PD identification based on 500 million measurement results* Precise online PD mapping with PD transponder
-
Product
Electrical Safety Multi-Analyzer
TOS9300 Series
-
The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
Battery Charger-Analyzer for small battery systems (up to 10A-Hr)
miniMasterCharger
-
The miniMasterCharger is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.With its multiple modes of operation of Constant Current Charge (dual and single rate), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge (analysis), Resistance Discharge (analysis) and Full Discharge (deep cycle), the miniMasterCharger can satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit (no load) and Overvoltage conditions.
-
Product
48V / 200 Amp Load
BD12-48P-24/12
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 12V, 24V and 48V Battery systems and isextremely cost effective.
-
Product
110V / 100 Amp Load
BD12-110P
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 110V battery systems and is extremely costeffective.
-
Product
Intelligent Battery Charger-Analyzer for Battery Systems
SuperMini
-
The SuperMini is an instrument designed to charge, trickle charge and analyze ( discharge ) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.With its multiple modes of operation: Constant Current Charge ( dual and single rate ), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge ( analysis ), Resistance Discharge ( analysis ) and Full Discharge ( deep cycle ). The SuperMini can satisfy the requirements of most ( Up to 40 A-hr ) rechargeable battery systems.The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit ( no load ) and Over-voltage conditions.Two large LED digital meters permit the simultaneous monitoring of voltage and current, while eight indicator lights display the status of the operation.
-
Product
Battery Discharger Charger Activator
-
KV Hipot Power Test Equipment Co.,Ltd
Battery Regeneration is a portable and compact tester which is used on discharging, charging and activating for disabling individual cell batteries.
-
Product
Stationary Battery Comprehensive Tester
SAT-AG Series
-
Shaanxi Aitelong Technology Co., Ltd
SAT-AG Series Stationary Battery Comprehensive Tester is a kind of product introduced according to the market demand, which integrates the two major functions: on-line monitoring and capacity check test, with higher integration and better functions.SAT-AG is specifically designed for the maintenance of the lead-acid battery discharge in the electricity and telecommunication sector. It is a new high-tech intelligent product that provides safe, reliable and convenient constant testing equipment for the DC system(Direct current system) users.
-
Product
Insulation Tester
AD-2025
-
Measuring voltage control during measurement, Insulation measurement up to 400 G W. Elimination of trough resistance insulation ? 3 connectors measurement method, Autoranging, Auto-Discharge facility safely discharges the connected circuit after a test, 5 minutes, 1 minute at will shorter measurement,
-
Product
25 Channel Potentiostat/Galvinostat
ArrayPGstat
-
For any selected cutoff voltage or current, early finishers are held at open circuit until all cells complete the charge or discharge period. All cells are switched at identical state-of-charge.- Multichannel potentiostat/galvanostat- Compliance voltage ±15 V- Voltage control ±10 V- Waveform signal sources (4 maximum)- ±100mA/channel (40 channels maximum)- 8 kHz bandwidth- Maximum scan rate 100 V/sec- Battery charge-discharge cycling: Time and/or voltage switching parameters.
-
Product
RiverRay ADCP
-
Teledyne Marine RD Instruments
Go straight to work collecting highly accurate stream and river discharge data with the RiverRay Acoustic Doppler Current Profiler (ADCP).
-
Product
ESD Event Detector
PED-718
-
The PED-718 is a portable indicator that will help you quickly detect ESD events in your process. If you’re handling ESD sensitive devices, use the PED-718 to detect and count discharges as well as showing you the relative strength of each ESD event.
-
Product
Radiometer
X1-1-RCH-116-4
-
The X1-1 radiometer from Gigahertz-Optik features an RCH-116-4 detector and is ideal for measurement of the irradiance of high power LEDs in the UV-A and blue light range. The device can accurately measure irradiance levels of up to 40,000 mW/cm². One of the outstanding features of the RCH-116-4 detector is its proven concept of a passive radiation absorber coupled to a UV sensor. This provides stability even in high temperature and intense UV radiation environments. In addition to the passive radiation absorber, the device also has a cosine-corrected field of view. The sensor’s housing also serves as a handle. The battery-powered X1-1 optometer supports a usable dynamic range from less than 1 mW/cm² to 40,000 mW/cm² thanks to its high-end signal amplifier. It can be used to perform precise measurements of up to 5 standard LED wavelengths for which the detector was calibrated for active irradiance. In addition to the CW measurement function, the device also has a dose measurement function. The radiometer can be used with other detectors from the RCH series. e.g. for gas discharge lamps. Remote control of the device is possible via its user software and a software development kit is offered for integration of the device in the user’s own software.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
Ultrasonic Leak Detector
ULD-420
-
When equipment begins to fail due to an air or gas leak or vibration, or electrical discharge, the leakage point emits an ultrasonic sound wave that is above the natural range of human hearing. The ULD-420 Ultrasonic Leak Detector converts this ultrasonic sound into a signal that can be used to pinpoint the exact location of the equipment failure. When working in unpressurized systems or the pressure is not sufficient enough to detect or verify a leak with the Receiver alone use the Transmitter.
-
Product
Seaward HV Test Equipment
-
Experts in High-Voltage Test Equipment Seaward has been designing and manufacturing high-voltage test equipment for over 37 years and continues to innovate and bring the best instruments to the market. Choose from phasing sticks, safe discharge rods, voltage indicators and more.
-
Product
EMC Testing Services
-
Our sophisticated technology can meet the diversified needs of customers. Component Tests: Immunity, Radiated Immunity, ALSE, TEM cell, Bulk Current Injection, Stripline, Conducted Immunity, Transient Immunity, Power Supply Variations, Electrostatic Discharge Emissions, Radiated Emissions, Conducted Emissions, Transient Emissions. Vehicle Tests - Radiated Immunity, Radiated Emissions.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Qualification and Quality Control Tests
Techsquare
-
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.
-
Product
20KV 30KV Electrostatic Discharge Generator ESD
ESD-202AX
-
Shenzhen Chuangxin Instruments Co., Ltd.
ESD simulator is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322. The ESD generator is designed for the assessment of electrical and electronic equipment to withstand ESD performan
-
Product
Electrostatic Discharge (ESD)
-
The sudden, momentary flow of electric current between two objects with different electrical charges.
-
Product
Corona Effect Camera
CoroCAM 8 UAV
-
*High-sensitivity UV detector, which can detect UVc light at 2.05×10-18 Watt/cm2, this allows detection of the smallest corona discharges.*9Hz (or 25Hz optional) IR radiometric camera module*Control of a limited number of camera functions from a standard RC controller using PWM or SBUS.*Remote control of all camera functions from the laptop via an Ethernet link.*Soft sync or staggered zoom of the 3 channel cameras. The IR and UV channels are digitally zoomed in, which is visible...optically zoomed in to the minimum FOV, and then digitally zoomed out.
-
Product
Battery Capacity Tester
BLU-A Series
-
The battery capacity test is performed to determine the health of a battery. DV Power’s battery load unit BLU-A is a portable, powerful, and lightweight solution for battery capacity measurement. It is applicable to any battery string such as lead-acid, Li-Ion, Ni-Cd, etc., with up to 500 V battery voltage. As a special feature, BLU100L model enables the capacity testing of a single Li-Ion cell.The capacity test is performed in an accurate and user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.Battery load unit BLU-A enables setting discharge currents up to 240 A, with a resolution 0,1 A. Furthermore, if higher currents are required, BLU-A units can be connected in parallel, or additional BXL load units can be used.The instrument offers the best power-to-weight ratio in the market. BLU-A models start from 12,8 kg / 28.2 lbs and deliver up to 28,4 kW of power.The user can select three discharge modes:Constant current,Constant power,Constant resistance.Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.The instrument monitors discharge parameters in real-time during the capacity test. A 4,3-inch touch screen display shows battery voltage, current, elapsed time, and capacity during the entire test. Also, BLU battery load unit can be used with DV-B Win software. As a result of that, a user can see a detailed numerical and graphical presentation of key parameters and can create reports in various formats.Testing with BLU-A doesn’t require a disconnection of the battery from the testing equipment.
-
Product
Leakage Test
-
Leakage current and discharge current depend on the insulation of the device. The measurement simulates various fault situations that could occur during operation. The test determines whether the measured current is within the permissible limits and poses no danger to the user in case of a fault.
-
Product
Power ICs - Smart Load Switches
-
Combining multiple functions in a single IC, Vishay smart load switches eliminate the need for external circuitry . A simplified GPIO interface allows for power distribution and sequencing of multiple sub-systems. Slew-rate-control devices provide a controlled supply ramp to reduce inrush current, while fault protection and isolation switches increase robustness with reverse current, overtemperature, current limiting, and short circuit protection features. The ICs offer quick output discharge and small footprints, while their integrated design saves PCB space compared to discrete solutions, reduces BOM counts, and lowers manufacturing costs.
-
Product
ESD Protection
-
Protection against electrostatic discharges (ESD) is part of EMC Immunity (Electro Magnetic Compatibility) requirements. It is the ability for equipment to properly operate in its electromagnetic environment by limiting the reception of electromagnetic energy that may cause physical damage. ESD can be either conducted under the form of a transient voltage or can be radiated due to its fast rising time: powerful harmonics will generate erratic behavior by the application by coupling with other signals. Printed circuit boards must be protected against the effects of electrostatic discharge.
-
Product
Passive Component ATS
-
Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe
-
Product
Test Line • Equipment For Testing For Function
-
The test equipment is used for qualitative functional testing of discharge power supply units and / or ionization units from the static line and air line (discharge). The devices are usually operated with a single button and indicate via LED, whether the device under review functions properly.
-
Product
TE-Metrology
-
HIGHVOLT Prüftechnik Dresden GmbH
The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components