Frequency Calibrators
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Electronic Calibration Module, DC To 9 GHz, 2-Port
N7552A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
7-Meter Laser Head Cable
10882B
Calibration Cable
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
Electronic Calibration Module (ECal), 50 GHz, 2.4 Mm, 2-port
N4693D
Electronic Calibration Module
The Keysight N4693D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4693D is a precision 2-port ECal module that supports 2.4 mm connectors up to 50 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4693D is included for securing your ECal module and accessories.
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Calibration Kit YAV90MMU
YAVMMUCK
Mechanical Calibration Kit
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Calibrators
-
Is a device used to adjust an instrument accuracy, often associated with a specific application.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
Mechanical Calibration Kit
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Product
Frequency Extension Calibration Kits
FEK
-
Farran’s FEK-xx-0001 calibration kit provides accurate calibration of the Vector Network Analyzer (VNA). It is compatible with TRL and SOLT calibration techniques and allows for a full 12-term port calibration.
-
Product
Calibrator
-
Sanwa Electric Instrument Co., Ltd
Is an equipment used to adjust an instrument accuracy, often associated with a specific application: temperature, pressure, weight.
-
Product
Frequency Extender
DC100
-
The DC100 system can be installed in the HP8568B(see H96 option below) without compromising the performance of the original instrument. The spectral purity and power accuracy of the primary band ( 100hz to 1.5Ghz) are insured from corruption by careful design of the DC100 system. Additional protection of the primary band is guaranteed as the DC100 system is automatically switched off (all power removed) when in primary band operation.
-
Product
Calibration
-
The Young Calibration laboratory provides UKAS calibration (Laboratory 0604) services and testing to all industries whilst maintaining a reputation for quality, cost effectiveness and reliability.Water Flow Calibration, Oil Flow Calibration, Air Velocity Calibration, Humidity Calibration, Pressure Calibration, Temperature Calibration, Electrical Calibration, Mechanical Calibration, Automotive Calibration, Medical Calibration, On-Site Calibration,
-
Product
Frequency Dividers
-
These instruments feature a simple front-panel interface and provide low-jitter frequency division. A reset input (and manual switch) provides a method of synchronizing a high-speed input pulse train with lower-speed devices on the output.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
RF Electronic Calibration Module (ECal), DC To 13.5 GHz, 4-ports
N4431D
Electronic Calibration Module
The Keysight N4431D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4431D is a precision 4-ports ECal module that supports multiple selection of connectors like Type-N, 3.5 mm, 7-16 and 4.3-10 connectors and can be mixed up to 13.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
K-50 Series Probes
High Frequency Probe
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
Product
Frequency Doublers
-
Teledyne RF & Microwave offers several Frequency Doublers providing high fundamental suppression, broadband input/output frequencies, and low conversion loss figures for a variety of communications applications.
-
Product
RF Calibration
-
RF and microwave calibration procedures are complex, involving many general purpose test instruments, accessories, components, cables, adapters and connectors. However, Fluke RF calibration noise reference sources enable many of these test instruments, components, and accessories to be replaced by just one instrument, speeding up calibration procedures and reducing operator errors. Save time and money by simplifying processes for calibrating typical items in your workload, such as spectrum analyzers, RF level meters, and receivers.
-
Product
Calibration Services
-
Trescal US is accredited to ISO/IEC 17025, ANSI/NCSL Z450-1 and ANSI/NCSL Z540.3 through A2LA. Trescal has one of the largest scopes of accreditation in the country for electronic, physical and dimensional domains as well as being a factory-authorized service center for many International manufacturers.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Calibrators
-
Ensure the accuracy and reliability of your leak and flow testing instruments with our cutting-edge calibrator. Specifically designed for precision calibration, our product stands out in the market for its innovative technology and user-friendly features. Ideal for a wide range of industries, this calibrator is essential for maintaining the integrity of your leak and flow testing equipment. With its robust design and exceptional accuracy, our calibrator is a must-have for professionals seeking to uphold the highest standards in leak and flow measurement. Whether you’re in manufacturing, engineering, or quality control, our calibrator is the perfect tool to ensure your instruments are performing at their best. Discover the difference in precision and reliability with our top-tier calibrator for leak and flow testing instruments.
-
Product
PD Calibrator
-
PDCAL has excellent pulse-with stability; scale calibration factors are permanently stored inside its flash memory. Thanks to on board photo coupler PDCAL output pulse can be synchronized with the actual line frequency through external surrounding electrical light source systems.