Product
Transmitter (Export Only)
SMDB
-
The input section features the unique servo bias input circuitry with a standard TA5M type jack for use with electret lavaliere mics, dynamic mics, or line level signals. A DSP-controlled analog audio limiter is employed before the A-D converter. The limiter has a range of more than 30 dB for excellent overload protection and a dual release envelope that makes the limiter acoustically transparent while maintaining low distortion. The limiter recovers quickly from brief transients, with no audible side effects, and also recovers slowly from sustained high levels to keep audio distortion low while preserving short term dynamics.
-
Product
WiFiScope WS5+SureConnect: 500 MS/s 250MHz BW, 2 Channel, Digital Storage Oscilloscope, 40MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
WS5-540XMS-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.
-
Product
Bench Digital Multimeter, Calibrated, Data, 1 kV, 10 A, 3.8 Digit
72-1015 CAL D
-
The 72-1015 CAL D from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Product
NI-9476, 36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module
785045-01
Digital Module
36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module - The NI‑9476 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 36 V,based on the external power supply, and features transient overvoltage protection between the output channels and the backplane. You can programmatically monitor the built-in overcurrent and short-circuit protection status of each channel.
-
Product
Shock Test System
-
Labtone Test Equipment Co., LTD
Products are inevitably affected by impact, bump, free fall, tumbling etc. during production, transportation, loading and unloading as well as during the use of the products. All of these are transient excitation on the object, causing the object to produce mechanical characteristics of high speed, acceleration, strain rate instantly. These kind of characteristics are completely different from that in static load, and may cause problems to the object in terms of structural strength and stability and sometimes the object may fail. Therefore, it's necessary to study the effect of impact and reproduce the shock environment, to assess the structural strenghth and performance of the object under shock environment.
-
Product
Mechanical Shock Testing
-
Classical • Half-sine • Sawtooth • Shock Synthesis • Sustained Presure Shock Response Spectrum (SRS) • Transient Shock Response
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-02
Current Input Module
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
Acceleration Simulation Mode (ASM) Roller Set
ASM-P | VP 230046
-
Maschinenbau Haldenwang GmbH & Co. KG.
The ASM-P roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97. The increased tractive force of its eddy current brake means that the ASM-P is also suitable for power measurements at constant speed and constant tractive force.
-
Product
WiFiScope WS6+EMI: 1 GS/s 250MHz BW, 4 Channel, Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
WS6-1000XME-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.
-
Product
Photon Counting Cameras
-
Photek photon-counting camera systems are unique as they provide the ability to capture and integrate an image in real time. These systems are ideal for extremely low photon emission applications such as bio-luminescence, chemi-luminescence and weak fluorescence. The ability to accurately analyze transient events is a key feature of this product. The length of time that the image can be integrated is limited only by disc space, and allows the user to fully capture real-time events. X, Y and time co-ordinates for post acquisition analysis is also recorded. X-ray and vacuum imaging camera options are also available.
-
Product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
-
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.
-
Product
PXA Signal Analyzer, Multi-touch, 3 Hz to 50 GHz
N9030B
Signal Analyzer
Accelerate innovation in demanding applications with measurement options that range from excellent to exceptionalExtend frequency up to 110 GHz with Keysight smart mixersCapture transient or intermittent signals with real-time spectrum analysisSimplify application-specific testing with X-Series appsPerform deeper troubleshooting with the 89600 VSA software
-
Product
Solar Cell Simulation
Setfos
-
Easily calculate the short circuit current, open circuit voltage Voc and fill factor with Setfos. Tweak the layer stack and add light scattering layers for enhanced absorption. Optimize for AM1.5 or specific wavelength bandsElectrical IV curvesCurve fitting & parameter extractionAC simulation and transient experiments like photo-CELIVAdvanced device physics: SRH-recombination, excitons, ... Design anti-reflection coatings or transparent cells
-
Product
Fault Passage Indicator for Lines
LineTroll R400D
-
LineTroll R400D Fault Indicator indicates earth- and short-circuit faults and can distinguish between permanent and transient faults. The indicator has two sensors and use both the electrical field and the magnetical field to detect faults on all three phases.
-
Product
HandyScope HS4 DIFF: 10 MS/s 100MHz BW, 4 Channel, USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS4-10-DIFF
-
The Handyscope HS4 is the successor of the popular Handyscope HS3. Built for customers that want to extend their measuring capabilities even further, this powerful computer controlled measuring instrument now features four input channels. The HS4 has just like it's predecessor the four main measuring instruments: a Multimeter, an Oscilloscope, a Spectrum analyzer and a Transient recorder.
-
Product
C Series Strain/Bridge Input Module
Strain/Bridge Input Module
The C Series Strain/Bridge Input Module works with higher-channel-count, dynamic strain measurement systems. Modules can acquire measurements from up to eight channels, with compatibility options for quarter-, half-, and full-bridge sensors. The C Series Strain/Bridge Input Module is ideal for application channels requiring measurements at particular times, such as impact tests. It includes built-in voltage excitation, as well as transient isolation for high-common-mode noise rejection and improved safety.The C Series Strain/Bridge Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
-
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
Product
NI-9472, 24 V, 8-Channel (Sourcing Output), 100 µs C Series Digital Module
783907-01
Digital Module
24 V, 8-Channel (Sourcing Output), 100 µs C Series Digital Module - The NI‑9472 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 30 V, … features transient overvoltage protection between the output channels and the backplane, and has an LED that indicates the status.
-
Product
8 Channel Sample & Hold and Signal Conditioning Board
-
Same features of 8 Channel Sample & Hold and Signal Conditioning Board plus connection and transient protection for Group3 B (digital) and D (analog output) boards.
-
Product
Stainless Steel High Performance Flow Sensor
2540
-
The Signet 2540 Paddlewheel Flow Sensor offers field-replaceable electronics and transient voltage suppression (TVS) to provide greater immunity to large voltage disturbances (i.e. lightning) sometimes encountered in field wiring. Sensors can be installed in DN40 to DN600 (1 to 24 in.) pipes using the 1 inch NPT or ISO 7/1-R 1.5 threaded process connection. The sensors are also offered in a hot-tap configuration with a bleed valve service without process shutdown in pipes up to DN900 (36 in.). Both styles of sensors must be used in full pipes and can be used in low pressure systems.
-
Product
PXI-6122, 4 AI (16-Bit, 500 kS/s/ch), 8 DIO, PXI Multifunction I/O Module
779179-01
Multifunction I/O
4 AI (16-Bit, 500 kS/s/ch), 8 DIO, PXI Multifunction I/O Module—The PXI‑6122 is a simultaneous-sampling, multifunction data acquisition device. It offers analog input, digital I/O, two 24‑bit counters, and digital triggering. The PXI‑6122 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Laser Flash Photolysis
-
This system that makes complex electronics, cumbersome software and large optical benches a thing of the past. The LFP system incorporates everything needed except the excitation laser. This is a simple, yet powerful instrument, ready to perform a wide range of time resolved kinetic and spectroscopic measurements involving transient absorption or diffuse reflectance. The LFP system, including the monochromator and digitizer is completely computer controlled, making it easy to obtain
-
Product
Fast Transient Burst Simulators
FNS Series
-
A simulator to reproduce fast repetitive high frequency pulses which are generated when switching ON/OFF electric current on the inductive load. International Standard IEC 61000-4-4 defines immunity tests for power supply lines or I/O signal lines against fast transient repetitive bursts. Also adopted as a Japan Industrial Standard.
-
Product
Non-Multiplexed High Speed Continuous Function Card Overview
-
This type of system can be designed with benefits of both the multiplexed amplifier-per-channel and transient recorder systems. Benefits of the non-multiplexed amplifer-per-channel system include: High Sampling Rates: With an ADC per channel, the sampling rate is not encumbered with considerations such as multiplexing and post-amplifier settling time.Superior Filtering: With an ADC per channel, digital filtering can be used to augment analog filtering to achieve better anti-aliasing performance with much lower effective sampling rates.Superior Phase Matching: Digital filtering provides much steeper, more predictable rolloff rates and phase characteristics than analog filtering with greater stability with time and temperature changes at lower cost.
-
Product
NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module
780159-01
Voltage Input Module
300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.
-
Product
Secondary Injection Equipment for Relay Testing
-
Portable equipment to test all types of protective relays and power system protection schemes. Automatic relay testing software, Comtrade transient playback and test reporting.
-
Product
Motor Exhaust Gas Sulfur Analyzer
MEXA-1170SX
-
The MEXA 1170 SX is a new instrument used to measure sulfur for after treatment and transient lubricant oil consumption. The analyzer uses ultraviolet fluorescence (UVF) for detection and it can be operated in a total sulfur mode, analyzing sulfur oxides, hydrogen sulfide and all organic sulfur compounds. An inorganic sulfur mode will analyze hydrogen sulfide and the sulfur oxides. The final operational mode will analyze just the sulfur oxides. Any one of these modes can be selected by the user from a front panel interface.
-
Product
Power Discrete Tester
Mostrak-2
-
M2 test system has multiple test generators which cover static and dynamic test procedures. It is our first truly modular tester which allows for the system to be upgraded and expanded when needed. M2 are designed to get the tester as close as possible to the handler interface and operator at the highest possible speeds. M2 is capable of HV (3 kV) and LV (600A) testing and has dynamic switching capabilities up to 1200V. MOSTRAK systems can test the following device types: MOSFET, IGBT, Bipolar transistor, Diode - rectifiers, Thyristor (SCR) - Triac, Linear voltage regulator (VReg), Transient voltage suppressor (TVS).
-
Product
WiFiScope WS5+SureConnect: 200 MS/s 250MHz BW, 2 Channel, Digital Storage Oscilloscope, 20MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
WS5-220XMS-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.With a WAN connection, worldwide measurements can be performed. Specific knowledge on networks is not required. The Multi Channel software gives an overview of the available USB instruments and network instruments. Simply tick the instrument and measuring can start. The WiFi oscilloscope has the following advantages: fully wireless measurements via WiFi are performed (galvanically isolated) because of the built-in battery mobile measurements are possible, e.g. on transport systems and moving installations LAN and WAN data acquisition is available for long distance measurements continuous realtime highspeed data acquisition over both WiFi and LAN/WAN are available USB measurements for stand-alone applications and highspeed data acquisition up to 200MSa/s.
-
Product
Mezzanine System
5093
System
ECM P/N 5093 provides 2 independent full bridge circuits. The two full bridge circuits can be used together to drive one small two phase stepper motor. Each full bridge circuit can drive one small dc motor or other bipolar load. Note all inductive loads should employ transient protection.