Probing Interfaces
Connect ATE instrumentation to interface test adapter.
-
Product
High Current Probes for EV Battery Packs
High Current Probe
Up to 500Amps - customized connections - battery pack charging.
-
Product
Godzilla High Current Probes, 150 Amp
HC500
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type Q, Ø0.80mm, 305gf
K100-Q080305-SKAU
Spring Probe
K100 Series, Pitch 100mil, Tip Style Q, Tip Diameter Ø0.80mm, Spring force 305gf, Steel with Gold Plating.
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25I40-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1Z1-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3L5
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
USB-8501, 2-Port, Low-Speed/Fault Tolerant, USB CAN Interface Device
786307-01
CAN Interface
The USB-8501 is a low-speed controller area network (CAN) interface for developing applications with the NI‑XNET driver. The USB‑8501 is powered over the USB bus and does not require external power. It excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals such as bus monitoring, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex applications. The USB‑8501 is available with a three‑pin COMBICON synchronization connector for triggering and synchronizing the internal hardware timebase with other devices.
-
Product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3E-1
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
CP-4x Battery Probes
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Digital/Pattern/PE Card
PA32S
Interface Card
The PA32S represents a new level of performance and capabilities for PXI-based digital instrumentation. Based on the proven architecture of the PE32, the PA32S offers high performance pin electronics and an enhanced timing generator in a compact, 3U PXI form factor. Each card can function as a stand-alone digital subsystem or if required, multiple cards can be interconnected, supporting up to 512 bi-directional pins (16 boards). The PA32S also supports deep pattern memory by offering= 32 M of on-board vector memory with dynamic per pin direction control and with test rates up to 33 MHz. With new 32M capture/log memory, PA32S can capture 32 channels fail log.
-
Product
CP-2XX-6 Battery Probes
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1T-8-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Remote Switch Probe
U5404A
Switch Probe
This 18 mm test probe is highly recommended for CAT IV environment and is compatible with the U1281A/82A handheld DMMs
-
Product
500 MHz Active Differential Probe
AP033
Differential Probe
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
Alternate 6.00 (17.00) - 2.50 (71.00) General Purpose Probe
P2262AG-1C2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
High 3.12 (88.00) - 8.00 (227.00) Bead Probe
BTP-72F-8
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
High 1.73 (49.00) - 8.00 (127.00) High Performance Lead Free Probe
LFRE-1L24-8
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
MIL-STD-1553 PCI Interface Card
PCI-1553
Interface Card
Alta Data Technologies’ PCI-1553 and PCIC-1553 (PMC on PCI carrier) interface modules are multi-channel (1-4) 1553 cards supported by the latest software technologies. These PCI cards are based on the industry’s most advanced 32-bit 1553 FPGA protocol engine, AltaCore™, and by a feature-rich application programming interface, AltaAPI™, which is a multi-layer ANSI C and Windows .NET 2.0 (MSVS 2005 C++, C#, VB .NET) architecture. This hardware and software package provides increased system performance and reduces integration time.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25T30-6.5
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
10-Ch Pneumatics Selftest Module
YAV90PNT
CAN Interface
Use this module in your self test diagnostics fixture. The YAV90PNT can be used as counterpart of the YAV90PNE, to test that is working properly.
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2B30-1
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Elevated 1.68 (4.00) - 7.00 (198.00) Bead Probe
BTP-1HL-7
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
USB-485/4, 4-Port, USB, RS485/RS422 Serial Interface Device
778476-94
Serial Interface
The USB‑485/4 interface transforms your USB port into a single asynchronous serial port for communication with RS485 and RS422 devices. You can use a USB‑485/4 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Passive Probe, 100:1, 1.5 GHz, 1.3 M
N2876A
Oscilloscope Probe
The N2876A passive probe offers DC to 1.5 GHz and 100:1 attenuation factor to measure fast edges in high speed applications more accurately. This probe needs 50 Ω input on the oscilloscope.
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1B-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-W
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64





























