Product
Spectrum Analysis, Up To 13.5 GHz
S930901B
-
The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.
-
Product
RF Proximity Detector
Type RPD-2 AND Type RPD-2A
-
The Type RPD-2 Radio Frequency (RF) Proximity Detector is designed to detect and locate devices that radiate radio waves in the high frequency to low microwave frequency range. Such devices often include surveillance and “spy” equipment. The Type RPD-2, when used with the different sensors, will detect the emanation of the radio wave within a confined area, and then isolate its location to within approximately a square foot. The type RPD-2A may be used as an RF field strength indicator for antenna field strength measurements. The RPD-2A is identical in function except that the meter scale is calibrated in relative dB units.
-
Product
Shunt Isolation Amplifier
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Especially to accurately measure large DC currents via shunt resistors, ie for making isolated detection of mV voltage on shunts. Variants with calibrated range selection. Working voltage up to 3600 V AC / DC.
-
Product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
-
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
Product
DC Precision Measuring
-
Precision instruments for calibrating and monitoring. Our line of Precision Bridges, Decade Boxes, Galvanometers, Potentiometers, and standard high precision resistors, allow customers the accuracy and quality demanded in a precision device.
-
Product
Test and Measurement Pressure Transducer
P895
-
The P895 is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover.
-
Product
Proximity Sensors
-
Premier Electrosystems is an esteemed name in the manufacturing of inductive proximity switch, photo sensors, capacitive sensors, magnetic sensors, hall effect sensors, analog sensors, encoders, infrared sensors, etc. with NABL calibration certificate
-
Product
Temperature Calibration System
-
Thermal Engineering Associates, Inc.
Systems for determining relationship between temperature-sensing junction voltage versus junction temperature of diodes, integrated circuits and thermal test die. Provides internal current sources, voltage measurement to 1 mV, and temperature measurement to 0.1ºC. 16-channel capability with optional printer and serial port data output.
-
Product
ICP Microphone System
378C01
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
E-Series Average Power Sensor
E9301B
Power Sensor
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm10 MHz to 6 GHz frequency coverage for Wireless Comms formats Low SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Torque Analyzers & Sensors
-
If torque tools slip out of calibration, that could impact the quality of your products. Having an accurate way to regularly test calibration onsite is a great way to reduce risk and ensure safety. With Mountz torque analyzers and sensors, you can test tools before they go into service every day. This prevents employees from working with miscalibrated tools and enhances quality management. It’s also more efficient to use your own torque testing equipment since you can evaluate your tools without sending them to a laboratory. Whether you want stand-alone sensors for hand and power torque tools or run down adapters that simulate actual joint conditions, Mountz has many options to choose from.
-
Product
Gas Calibrators and Zero Air Generators
-
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
Product
Multilogger
M1440
-
Universal datalogger with 4 hardware inputs and external CO2 probe. Multilogger can be installed permanently to Ethernet network or work as portable device. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
-
Product
TSA USB Adaptor Series
-
Is a hardware interface for TSA USB mini spectrum analyzer. It converts the USB interface into the RS232 interface. It is simply a command set of the TSA USB mini spectrum analyzer. It also includes the calibration calculation so that TSA USB mini spectrum analyzer can directly work on embedded system when using it.
-
Product
Calibrated Pocket Magnetometer
M 25
-
Instruments available in 8 different, Full Scale, Gauss Ranges.
-
Product
Digital (1kV up) H.V. Insulation Tester
6211A IN (Ranges: 1kV, 2.5kV, 5kV, 10kV)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● Fully protected: crow bar.● Carry case.● EEPROM calibration.
-
Product
PXI-6239, 8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module
779626-01
Multifunction I/O
8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6239 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6239 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6239 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
Thermocouple Vacuum Gauge Tubes for Medium Vacuum
DV-6 Series
-
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily installed into vacuum systems and when properly excited, generates a thermoelectric voltage to provide a vacuum pressure measurement based on gas density. The DV-6 thermocouple vacuum gauge tube fully compensates for temperature and rate of temperature change.Thermocouple gauge tubes are calibrated on vacuum systems that contain N2 or Air, but can be used with other gases. Additionally, thermocouple gauges and their controllers can be recalibrated when a replacement thermocouple gauge tube is installed, following instructions in the manual. However, our DB-20 reference tube is available to confirm meter/controller performance. A complete line of installation accessories are also available to simplify the integration of our thermocouple gauge tubes into a variety of vacuum systems. Our goal is to provide “one less thing to worry about”, when performance matters! With a wide range of meter, fitting, relay and output options, the DV-6 series provides a reliable pressure measurement in numerous industries and applications.
-
Product
Testwave Calibration
-
Testwave® LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send you recall notices before your equipment calibration expires, and if we don’t hear from you, we will call, to make sure you stay in compliance with your calibration requirements. Calibrations are performed at your facility, or at our Sparks Nevada laboratory.
-
Product
CW Power Sensors
E-Series
-
The E-Series of power sensors have their calibration factors stored in EEPROM and operate over a wide frequency and dynamic range.wide frequency coverage from 10 MHz to 26.5 GHz (sensor dependent)wide dynamic range sensors (-70 to +20 dBm)accurate CW average power measurementsoperates with the EPM, EPM-P, and P-series power meterscalibration factors stored in EEPROM
-
Product
Low Torque Reaction Sensors
MTX
-
The MTX is a low torque sensor designed for calibrating and testing small hand screwdrivers, torque wrenches and power tools. With its low profile design, the calibration instrument can be used for automated applications, by mounting it to a palletized system. This saves time as there is need to remove the driver from the robot or off the automated system for calibration. These versatile torque sensors are used in conjunction with a torque tester.
-
Product
Portable Calibrator
MC141
-
Voltage range from 0 to 750 V DC/AC with uncertainty 0.01% Current range from 0 to 2 A DC/AC with uncertainty 0.02 % Calibrated sinusoidal output signal DC - 1kHz. Set standard resistors from 10 Ohm to 100 MOhm in decade values with uncertainty 0.02 %. TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250 oC to 1850 oC
-
Product
Novo-Gloss 60 Glossmeter
-
60 degree glossmeter for general gloss measuring applications such as print, packaging, paint. 2 year warranty, NIST traceable calibration standard.
-
Product
Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/P -
-
SEM1605/P - Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
-
Product
Keysight 4-Channel D/A Converter with Waveform Memory for 34980A
34951A
Digital / Analog Converter
The Keysight 34951A module for the 34980A Multifunction Switch/Measure Unit has four electronically calibrated analog channels that can output up to +/-16V DC or +/-20mA DC with 16 bits of resolution. Each channel can be updated individually with a 200 kHz update rate. You can use the standard waveforms provided or create your own with over 500,000 points. These points can be dynamically allocated among one or more channels and output as a point-to-point arb.
-
Product
E-Series Average Power Sensor
E9300B
Power Sensor
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
Proprietary Software
WinFT
-
WinFT is our proprietary software which makes D&P instruments so functional and easy to winft1_largeuse. Based on the Windows operating system, this software provides simple and intuitive control of the instrument. All of the usual File functions are available, as well as controls over instrument settings such as resolution, apodization, zero-fill and number of coadds. Display options enable the user to display interferograms, spectra or both, as well as to adjust plot scales and units. Onboard math processing allows for real-time calculation of ratio, difference, and absorbance, and when using our calibrated hot-cold blackbody calibrators, the ability to measure calibrated radiance. Further, WinFT offers the ability to measure sample temperature in the radiance function by matching a Planck to the calibrated radiance. With the gold diffuse plate, the software can also compute and display absolute emissivity of samples. Our software also enables exporting of data files, now made even easier with our USB and LAN connections. In addition, the software has been designed to be easily run using the keyboard function keys and single letter commands, making the use of a mouse in the field optionalas well as minimizing key strokes when taking measurements in the field.
-
Product
Thermal Tools
-
BMP Testing and Calibration Services Inc.
BMP Testing and Calibration Services, Inc. utilizes the latest thermal measurement equipment to analyze low to medium-conductivity materials, from ceramics, plastics, and polymers to coatings, composites, liquids, and building materials.
-
Product
Multi Function Calibrators
-