Strobe Light
Timed short bursts of light illuminating vibration and rotation frequency.
-
Product
Stabilized Light Source
SLS
-
Provides continuous wave and stable source of energy for loss measurements of fiber optic cable.
-
Product
ILT UV-VIS-IR Light Meters, Lux Meters & Radiometers
-
International Light Technologies
International Light Technologies has been developing and manufacturing high-performance light meters and measurement systems for over 50 years. Our comprehensive portfolio of light measurement products include radiometers, photometers, optometers, dataloggers, lux meters, chroma meters, spectrometers and spectroradiometers.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1I-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.83 (24.00) - 2.00 (57.00) Bead Probe
BTP-1F-2
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Pulsed Laser and LED Light Sources
NanoLED
-
The NanoLED range is a novel and economical light source system that utilizes pulsed laser diode and LED technology to generate short optical pulses over a wide range of repetition rates and wavelengths. Optical pulses as short as 70ps can be generated at repetition rates up to 1MHz.
-
Product
Vehicle Lighting
-
The lights are designed for both the retrofit and new build market and include normal visible, NVG Compatible, NVG Friendly and Covert technology. Solutions include infra-red (IR) external lights and low profile interior cabin lighting and task lighting.
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25T30-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Dual Wavelength Single Mode Light Source
FiberLink 6654
-
The Fiberlink 6654 Dual Wavelength Single Mode Light Source is a cost effective, compact, handheld light source. The temperature compensated outputs are calibrated to couple -10dBm of optical power into single mode fiber.
-
Product
Light / Lux Meter, Calibrated w/Data, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL D
-
The 72-7250 CAL D from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1T24-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Optical Light Source
CARY-LS300B
-
The CARY-LS300B optical light source provide 1310/1490/1550 nm three outputwavelengths to meet specific application requirements. It is a idea solution for the fiberoptic network characterization, out-door network construction inspection and lab application.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-1T-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-1A-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light / Lux Meter, 100000 lx, 100 lx, 5 %, 180 mm, 72 mm, 32 mm
72-6693
-
The Tenma 72-6693 is a high accuracy Illuminance meter. Featuring a dual function display, this meter can record both maximum, minimum and average readings. User selectable lighting types of tungsten/sun, fluorescent, sodium and mercury.
-
Product
Airy Beam Light Sheet Imaging System
Aurora
-
Aurora is an award-winning Airy Beam Light Sheet imaging system designed for researchers working in fields such as neuroscience, developmental biology, cancer biology, regenerative medicine and other bioscience disciplines, including Plant Sciences and Marine Biology. Compact, affordable and customisable, Aurora is available as a single and multiphoton light sheet fluorescence microscope for rapid, large 3D volumetric imaging, high resolution, multicolour, time-lapse imaging and live cell imaging. Aurora uses ground-breaking Airy Beam Light Sheet imaging techniques to achieve outstanding results in the field. It is currently in use by many leading organisations delivering results previously not possible.
-
Product
Fully Automated In-line Test System For LED Light Engines
-
We are pleased to announce that we have received an order for the supply of a fully automated in-line test system for testing LED light engines from ASD Lighting, based in Rotherham. The solution provided, consists of an in-line handler fitted with a vision system. The camera software is capable of learning the position of all LED’s on a new pcb, thereby reducing the time to introduce a new product. In addition to identifying the location of any missing or faulty LED’s the tester measures the colour temperature of every pcb. An image is taken of faulty units with the location of any missing LED’s identified
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25A-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Trailer Light Tester
Checkmate 1200
-
Checkmate 1200 is a good, basic light tester for trailer light systems that can also serve double duty to power anti-lock brake systems.
-
Product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Light Meter / Lux Meter / Illumination Meter
-
Indication3 Digits LCD Readings With Maximum Value 2000. Overload"OL" Display On LCD Photometer Range(nm)400~700 Sensitivity Peak Wavelength(nm)500 Photometer UnitsLUX or Foot-Candle (FC); 1FC=10.76 LUX. Measuring Range Scale0.1~19990 LUX. 0.01~1999 FC
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1I35-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1Z1-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.60 (17.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-72I8-2
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Light Source
UVM-SP-JW
-
Readouts of UV intensity and cumulative luminescence count are prompted either on the front panel or via the externally connected remote signal control. The UV intensity detection segment is intended to measure a specific intensity of light signals, while the cumulative luminescence count is designed to tally a cumulative count on all UV intensities measured, in conjunction with real-time calibration.
-
Product
Light Source Colorimeter
CX-HP2
-
Shenzhen Chuangxin Instruments Co., Ltd.
Light source colorimeter is a newly developed pocket colorimeter, adopting advanced spectrometer and microprocessor technology. It makes traditional laboratory instrument available for the production on-line quality acceptance, thus greatly improve the efficiency of fluorescent lamp, CFL, LED manufacturing.
-
Product
Light and Energy Meter
Model 656
-
OAI Model 656 Meter is designed for use with all mask aligners and flood exposure systems. For over 45 years, OAI is a world leader in UV Light & Energy Measurement Instrumentation used for reliable accurate calibrated control of the photolithography processes in the Semiconductor, MEMS, Wafer Packaging and Wafer Bumping Industries.
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25J-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1UN-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light Measurement Input Optics
-
International Light Technologies
Light measurement units are defined around very specific spatial responses. A carefully designed input optics system is essential if measurement accuracy is to be achieved.
-
Product
Inverted Light Microscopes
-
Inverted microscopes from Leica Microsystems are designed to meet the rigorous demands of life science as well as material science and industrial applications.





























