V.35
-
Product
NI-9425, 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module
779139-01
Digital Module
24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The NI‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The NI‑9425 offers isolation between the input and output banks from channel to earth ground. You cannot use the NI‑9425 in a CompactDAQ chassis to perform counter operations.
-
Product
Clamp Meter, Auto, True RMS, 1 kA AC, 600 V AC, 50 mm Jaw Opening Max.
72-10445
-
The 72-10445 is a Clamp Power Meter Clamp with phase sequence. It measures active power (W), apparent power (VA), reactive power (VAr), power factor, phase angle and active energy (Wh) with built-in phase sequence test. Also measures AC current, AC voltage and frequency.
-
Product
Portable Calibration Baths
6109A / 7109A
-
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
Product
16-bit, 100KHz, 16SE/8DIFF A/D Inputs; 8 14-bit, 30KHz D/A Outputs, 4 24V Digital I/O, All Isolated
CPCI-3120-16-8
-
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
Product
ATG CASSETTE PROBES
SERIES 110
-
ElectricalMAXIMUM CURRENT: 3 amps continuousat working travel, non - inductiveRESISTANCE: At 35 mA test current,50 mOHMS meanMaterial and FinishesPLUNGER: Heat treated berylliumcopper, 24 Kt gold plated over nickelBARREL: Nickel silver with 24 Kt goldplated ID and OD over nickelSPRING: Music wire, 24 Kt gold platedover nickelPIN: Heat treated berylliumcopper, 24 Kt gold plated over nickel
-
Product
Anemometers/ Tachometers
-
TES Electrical Electronic Corp.
Fast response propeAir flow volumeInstant/ avg/ V max flow measurement. VelocityTemperature and Humidity measurement. Calculate Dew point temperature, Wet bulb
-
Product
MIPI Camera Serial Interface
CSI
-
Arasan provides a Total MIPI CSI-2 IP Solution supporting two options: MIPI CSI-2 v1.2 for D-PHY physical interface only, and MIPI CSI-2 v1.3 for the new MIPI C-PHY v1.0 and D-PHY v.1.1, v1.2, and a future v2.0. Arasan offers the C-PHY in a combination configuration that supports both C-PHY interfaces and D-PHY interfaces. Our implementation makes efficient use of the high frequency signally pins for a minimal overhead to support both physical interfaces.
-
Product
Digital Sound Meter
SM-100
-
Model SM-100 Digital Sound Meter is ideal for measuring noise levels from 30 to 130 dB with accuracy of ±1.5 dB. Model SM-100 has a frequency of 31.5 Hz to 8 kHz, three different dB ranges, and a 1/2" condenser microphone. The SM-100 has two frequency weightings: the "A" weighting ranges from 30 to 130 dB, while the °C" weighting ranges from 35 to 130 dB.
-
Product
16-bit, 100KHz, 8SE/4DIFF A/D Inputs; 8 14-bit, 30KHz D/A Outputs, 4 24V Digital I/O, All Isolated
APCI-3120-8-8
-
*Optical isolation 500 V*8 SE or 4 diff. inputs*Data transfer rate: 100 kHz*16-bit resolution*8analog output channels*Data transfer rate:30 kHz*14-bit resolution
-
Product
20U (35") Non-Insulated Bus Bar
BB-35
-
20U (35") non-insulated bus bar provides cabinets with recessed rail option and a convenient, isolated common grounding mechanism.
-
Product
ATE System Power Supply, 300 V, 5 A, 1500 W
N5771A
Power Supply
The single output, 1500W N5771A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
Product
Multifunction Meters
-
Measures V, A, PF, Hz, KW, KVA, KVAr, Kwh, KVAh & KVArhTRMS MeasurementCan be used for Continuous MonitoringAuto / Manual Scroll Display (User Selectable)State of Art Microcontroller DesignPortable, Handy, Plug-n-Play and Easy-to-useLCD Display with BacklightRS-485 5KV Isolated Port (Optional) with MODBUS RTU Protocol (Optional)POWER MASTER Software for MIS Reports (Optional)
-
Product
Scienlab Battery Test System – Pack Level, 330 KW
SL1740A
Test System
Keysight’s SL1700A Scienlab Battery Test System – Pack Level Series allows to realistically emulate the environment of the future battery pack application in order to test the high-power battery pack comprehensively and improve its functions and safety. The growing demand of e-mobility increases the need of vast battery test labs for EV battery development. Keysight developed the SL1700A Series to accelerate the development and validation of batteries. It offers a voltage range of up to 1500 V and power options between 100 and 300 kW including a Performance Bundle to increase the power up to 330 kW. The new high-voltage SiC (silicon carbide) technology provides a high energy efficiency on a small footprint and helps to minimize your operating costs.
-
Product
USB Oscilloscope
Handyprobe HP3
-
The Handyprobe HP3 is a small and light weight USB oscilloscope. The Handyprobe HP3 combines a fast sampling up to 100 MS/s with a high input range of 800 V and a differential input in a small and light enclosure. Powered only by USB, this verstatile USB scope enables safely measuring high voltages anywhere in the field. Its rugged housing is specially designed for use in a dirty and rough environment but is compact enough to fit into any tool case.
-
Product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
-
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
Product
Narrow Band Filters (Single Octave)
NANO-POLE® Series
-
The NANO-POLE® is designed for optimal size, DC consumption, RF power handling, insertion loss, signal purity and linearity. The NANO-POLE® provides a minimum center frequency step size of 10 MHz typically but can be modified based upon request. The NANO-POLE® requires a +3.0 V supply that typically draws 5 mA when not hopping. The supply voltage should be adequately filtered as noise present on this pin will influence the RF signal purity. The NANO-POLE® uses SPI control interface.
-
Product
Programmable Step Attenuator, DC to 26.5 GHz, 0 to 11 dB, 1 dB steps
84904K
Attenuator
The Keysight 84904K programmable step attenuator offers coaxial measurements to 26.5 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life (greater than 5 million switching cycles per section) and attenuator range of 0 to 11 dB in 1-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with less than 2 dB of loss at 26.5 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
Product
PXI/PXIe High Voltage Multiplexer, Single 9-Channel, 2-Pole
42-321-124-HI
Multiplexer Module
The 40-321-124-HI (PXI) and 42-321-124-HI (PXIe) are single 9-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
Insulation Resistance Meter
SME1202
-
Scientific Mes-Technik Private Ltd
General purpose insulation resistance meter Analog indicator, High measurement speed Test voltage range: 10 V to 1000 V Suitable for Testing capacitor insulation test Easy operation
-
Product
Simulsat Multibeam Antennas
-
Antenna Technology Communications, Inc.
Simulsat is the world's only true multibeam antenna that receives up to 35 satellite signals simultaneously. Simulsat has and continues to deliver programming to millions of cable TV viewers worldwide. Taking the space of about 3 parking spaces, Simulsat pays for itself in space, savings and insurance for future channels and programming changes. Available in 3 size and performance variations: Simulsat 5B, Simulsat C/Ku and Simulsat 7, Simulsat is the only antenna you need.
-
Product
PXIe Precision Source/Measure Unit, 15 MSa/s, 100 FA, 60 V, 3.5 A DC/10.5 A Pulse
M9603A
Source Measure Unit
The Keysight M9603A is a PXIe precision SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
PXI-5422, 80 MHz Bandwidth, 16-Bit PXI Waveform Generator
779087-02
Waveform Generator
80 MHz Bandwidth, 16-Bit PXI Waveform Generator - The PXI‑5422 is a 80 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. The PXI‑5422 also features advanced synchronization and data streaming capabilities.
-
Product
Regenerative Power System, 80 V, ±250 A, 10 KW, 400/480 VAC
RP7945A
DC Power Supply
The Keysight RP7945A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
Product
DC/DC Converter 120 W
CTS-120-6867-D
-
DC/DC converter with 120 W from Premium | input ranges 14.4 - 30 VDC | output 24 V | operates in temperatures from -25 to +85 °C | designed according to EN50155
-
Product
AC/DC Power Supply 60 W
TR100M180
-
AC/DC power supply with 100 W from Cincon | input ranges 90 - 264 VAC | output 18 V | operates in temperature from -20 to +80 °C | provides 2 MOPP
-
Product
3U OpenVPX High Density Multifunction I/O Board
68CB6
Multifunction I/O
The 68CB6 is a Configurable Open Systems Architecture™ (COSA®) 3U OpenVPX™ board that is preconfigured with 10 different “inboard” I/O, measurement and communication functions. This Combination-function Board (CB) provides a full suite of some of the most common & useful function interfaces supporting many different applications. The 68CB6 features a wide but dedicated selection of functions: Standard Functionality Discrete I/O (DT1); Successive Approximation Register (SAR) ±100 V Analog-to-Digital (AD); Isolated High Voltage Analog-to-Digital (ADF); ±10 V Digital-to-Analog (DA); Thermocouple (TC1) or Resistance Temperature Detector (RT1); Full-bridge Strain Gauge (SG1); Transmission/gear box Chip Detection and Fuzz Burn (CD1); LVDT-to-Digital linear (LD6) displacement (position) measurement, AC Reference Source output (AC2); CAN bus communication (CB8). The 68CB6 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for external intermediate circuit considerations such as pull-up resistors or mechanical configuration jumpers. Inboard functions are software controlled and memory addressed, accessed in similar COSA® modular fashion to maintain seamless common NAI Software Support Kit & API/library structures.
-
Product
AC / DC Digital Power Analyzer
4016(800Vp,20Arms/200Ap)
-
To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.
-
Product
High Voltage SMU 2500 V
AXV7607
-
Generate extremely short, fully regulated voltage pulses of up to 2500 V. Measure leakage currents up to the pA range.
-
Product
JFET Input Amplifiers
-
Analog Devices JFET input op amps or FastFET high speed (>50 MHz) input op amps provide high input impedance and ultralow input bias currents for high speed applications. The majority of our FET input op amps feature wide supply ranges from +5 V to 12 V or higher and feature rail-to-rail outputs enabling wide dynamic range.
-
Product
COMPUTERIZED AUTOMATIC RELAY TEST SYSTEM
CVRT-S16
-
CVRT-S8 & S16 are ideal for automatic testing of ELECTRO MECHANICAL AND READ RELAYS (only DC relays) both for static and dynamic characteristics. This system scans at one stroke, all the parameters of the relay as per definition of test procedure. The test sequence can be pre-programmed and stored in the disk. You can select the tests as per your requirement. Can include or exclude the test and you can have several options to match your test definitions. Semi skilled person can be engaged for actual testing, as he need not make any settings and need not interpret the readings. The system conducts the tests and gives PASS / FAIL indication on overall test results. If a printer is connected, each test result will be printed.Test Parameters : -> Coil Resistance.-> PickUp/Pull In /Operating Voltage or Current Linear Ramp Method or Step Method.-> Measure Pickup Contact Gap FBB-LBB V or mA-> DropAway/Drop Out/Release Voltage or Current Linear Ramp Method or Step Method.-> DropAway Contact Gap FFB-LFB V or mA-> % Release Dropaway/Pickup-> Contact Resistance of all contacts both Front and Back contacts.-> Operating Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while Operating @ above-> Release Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while release @ above-> Difference of Operate Time - Release Time.-> Bridging Test or Non Overlap Test.-> Transfer or Traverse Times while Operate and release.-> Operate Time @2nd Set Voltage or Current.-> Release Time @2nd Set Voltage or Current.-> Power Consumption @ Rated Voltage.-> Coil Current @ Rated Voltage at Room Temperature.-> Coil Resistance Corrected to 20deg C.-> Timing Waveform Graph for all active Contacts.





























