Voltage Drop
electrical energy given up flowing through a circuit.
-
Product
NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module
785184-01
Voltage Input Module
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
Product
NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783107-01
Voltage Input Module
250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.
-
Product
300 Vrms, 50 KS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module
789126-01
Voltage Input Module
NI 9225 Snap-In, 3-Ch +/-300V Analog Input Module
-
Product
sbRIO-9225, Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module
780588-01
Voltage Input Module
Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The sbRIO‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three sbRIO‑9225 channels. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-02
Voltage Input Module
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
±10 V, 500 KS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
789124-01
Voltage Input Module
NI 9222 Snap-In, +/-10 V, 16-Bit, 500 KS/S, 4-Ch, SS AI C Series Module
-
Product
FD-11601, 8-Channel, ±10 V Powered-Sensor Voltage Input Device for FieldDAQ
786374-01
Voltage Input Module
The FD-11601 measures up to eight channels with a voltage input range of ±10 V. Each input channel supports TEDS and provides 24 V DC to power external-powered sensors without additional power supplies. The FD-11601 features 24-bit resolution, simultaneous sample rates up to 100 kS/s/ch, and channel-to-channel isolation. It is IP65/IP67 rated to be dust-tight and water-submersible, operates in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11601 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11601 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11601 is ideal for test cell and outdoor environments.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779373-01
Voltage Input Module
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
NI-9251, 3 Vrms, 102.4 kS/s/ch Simultaneous, 2-Channel C Series Voltage Input Module
783814-01
Voltage Input Module
3 Vrms, 102.4 kS/s/ch Simultaneous, 2-Channel C Series Voltage Input Module - The NI‑9251 with mini XLR is a low-distortion input channel that allows for the high dynamic range measurements necessary to fully test and evaluate modern audio outputs used in most consumer electronic devices. Unlike sound card-based solutions, you can quickly deploy the NI‑9251 to guarantee long-term measurement repeatability and increased test system uptime. To maximize low-noise benefits, the NI‑9251 differential input is provided through a mini‑XLR connector, which delivers a truly balanced input.
-
Product
REM-11100, 2-, 3-, 4-Wire, 4-Channel Voltage Input Module for Remote I/O
784748-01
Voltage Input Module
2-, 3-, 4-Wire, 4-Channel Voltage Input Module for Remote I/O - The REM‑11100 is a voltage input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11100 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. This module features 2‑, 3‑, and 4‑wire spring terminal connection methods, a built-in power supply for sensors, four selectable input ranges, and simultaneous sampling.
-
Product
NI-9224, ±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783862-01
Voltage Input Module
±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9224 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9224 is simultaneous sampling with two options for filtering a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
sbRIO-9223, Non-Enclosed, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
785480-01
Voltage Input Module
Non-Enclosed, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO-9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The sbRIO-92233 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the sbRIO-9223: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
Product
FD-11605, 8-Channel, ±60 V Voltage Input Device for FieldDAQ
786469-01
Voltage Input Module
The FD-11605 can measure up to eight channels with a voltage input range of ±60 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11605 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages of up to 1000 V. The FD-11605 has an ingress protection rating of IP65/IP67 (dust-tight and water-resistant),can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11605 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11605 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11605 is ideal for test cell and outdoor environments.
-
Product
sbRIO-9215, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Modul
780878-01
Voltage Input Module
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9223, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
781398-01
Voltage Input Module
±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9223 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9223: either four, 2‑position screw terminal connectors or four BNC connectors.
-
Product
NI-9228, ±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783861-01
Voltage Input Module
±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9228 performs differential analog input. With channel-to-channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9228 is simultaneous sampling with two options for filtering: a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
AC-Powered, AC Voltage Monitor
VAA/VQA
Voltage Monitor
NAI’s VAA and VQA are AC-Powered, AC Voltage Monitors used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits. These voltage monitors are ideally suited for rugged defense and industrial applications.
-
Product
NI-9263, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module
779012-01
Voltage Output Module
100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
FD-11603, 8-Channel, ±10 V Voltage Input Device for FieldDAQ
785639-01
Voltage Input Module
The FD-11603 can measure up to eight channels with a voltage input range of ±10 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11603 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages. The FD-11603 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11603 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11603 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11603 is ideal for test cell and outdoor environments.
-
Product
NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module
780159-01
Voltage Input Module
300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.
-
Product
NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
785503-01
Voltage Output Module
1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.
-
Product
NI-9263, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module
783740-01
Voltage Output Module
100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
sbRIO-9239, Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780875-01
Voltage Input Module
Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the sbRIO‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779014-01
Voltage Input Module
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
±10 V, 250 KS/s, 16-Bit, 16-Channel C Series Voltage Input Module
789113-01
Voltage Input Module
NI 9204 Spring Terminal, 16-Channel, +/-200mV to +/-10V, 16-Bit, 250 KS/s AI C Series Module
-
Product
NI-9215, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783739-01
Voltage Input Module
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
Product
NI-9220, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module
785188-01
Voltage Input Module
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
Product
NI-9201, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779372-01
Voltage Input Module
±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9201 is an effective combination of channel count and speed at a low price for an economical multifunction system. The module features up to 100 V of overvoltage protection for errant signal connection or unexpected signals to the individual channels.
-
Product
NI-9228 , ±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783861-02
Voltage Input Module
±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9228 performs differential analog input. With channel-to-channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9228 is simultaneous sampling with two options for filtering: a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
AC Voltage Monitors
Voltage Monitor