Scattering
a propagating wave or moving particle's linear trajectory, interrupted by non-uniformity in the medium they move through.
-
Product
Neutron Scattering and Beamline Systems
-
For optical, neutron and particle beam experiments, Cryogenic offers a range of split pair magnets. These allow strong magnetic fields to be produced in a small volume with maximum access to the working space. Split pair coils can be mounted to provide either a vertical field with horizontal access or a horizontal field offering horizontal or vertical access.
-
Product
Small-Angle X-Ray Scattering (SAXS) Products
-
Small-Angle X-Ray Scattering (SAXS) Products from Rigaku
-
Product
Multi-Angle Light Scattering Detector
PN3621
-
Since the 1990s Postnova has been a leading innovator and developer of special advanced online Light Scattering solutions for coupling with chromatographic separation systems. The first model was the PD2000 - Static Light Scattering detector for coupling with Asymmetric Flow FFF. Later on the models PN3020 SLS and PN3070 MALS have been launched. Based on these over two decades of practical experience, Postnova has collected a unique competence in the area of Laser Light Scattering and has developed the unique PN3621 MALS - Multi-Angle Light Scattering detector series. The model PN3621 MALS is a completely new type of high performance MALS detector system with a unique range of specifications.
-
Product
Evaporative Light Scattering Detector
ELSD-LTII
-
The ELSD-LTII utilizes a high-efficiency LED and enhanced digital signal treatment to minimize noise and deliver optimum sensitivity for trace analysis. An innovative cell design also reduces band broadening and allows sensitivity levels below 200 picograms. The high-performance optical detection system can also be used for combinatorial chemistry and high-throughput screening applications. The new Low Temperature Evaporative Light Scattering Detector (ELSD-LTII) is an easy-to-operate, universal detector that identifies analytes with uniform sensitivity regardless of their spectroscopic properties. It is not a spectroscopic detector. Instead, it removes the mobile phase through evaporation and then makes a light scattering measurement of the dried analyte particles.
-
Product
Gamma Detectors
-
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
Product
Hybrid Raman/Er-doped Fiber Amplifier
HFA5000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600nm.
-
Product
Laser Turbidity Meter
HU-200TB-EH
-
HU-200TB-EH is a laser-type turbidity meter that can measure turbidity of membrane filtered water, etc. with a resolution of 0.0001 degrees. A high-sensitivity turbidty meter with a minimum resolution of 0.0001 degrees at a measurement range of 0.0000 to 2.0000 degrees, which uses a long-lasting semiconductor laser as the light source and employs a transmission 90-degree scattering light method.This is best suited for sensitive measurement of turbidity on surface water.
-
Product
Converter
556
-
The dual channel converter 556 provides continuous inline, real-time measurement and control of turbidity. The customer’s specific factory calibration of the converter can be configured in ppm (DE), FTU or EBC. Combined with an optek TF56-N scattered light sensor the 556 converter is a cost-saving measuring system, providing reliable process measurements.
-
Product
3D Electromagnetic Simulation Software
XFdtd®
-
A full-featured simulation solver, XFdtd outpaces other methods in efficiency as the number of unknowns increases. XF includes full-wave, static, bio-thermal, optimization, and circuit solvers to tackle a wide variety of applications, including antenna design and placement, biomedical and SAR, EMI/EMC, microwave devices, radar and scattering, automotive radar, and more. It also works with Remcom's ray-tracing products to provide thorough simulation capability at the low-, middle-, and high-end of the electromagnetic spectrum.
-
Product
CG-MALS
Calypso II
-
Label-free, immobilization-free characterization of protein-protein and other macromolecular interactions with composition-gradient multi-angle light scattering.
-
Product
Laser Scattering Particle Size Distribution Analyzer
Partica mini LA-350
-
HORIBA's new LA-350 Laser Diffraction Particle Size Distribution Analyzer is the ideal combination of performance, price, and packaging. The LA-350 excels in applications as diverse as slurries, minerals, and paper chemistry. Based on the advanced optical design of previous LA-series analyzers, the LA-350 strikes a harmonious balance between high-functionality, easy operation, low maintenance, and cost-effectiveness.Bench space is used efficiently due to the LA-350’s compact size (297 mm x 420 mm). The clever design and precision, high quality manufacturing ensure convenient, reliable operation and accurate results, now with a wider size range (0.1-1,000 µm).
-
Product
Logger version 2-D electro-magnetic current meter
INFINITY-EM AEM-USB
-
Infinity EM is an autonomously deployable EM (electro-magnetic) current meter with a data logger. Due to the principle, the instrument provides high accurate 2-D current measurements in even low scatter fields, where ADVs (Acoustic Doppler Velocimeter) has difficulties. The measurement range is wide from 0 to ± 500 cm s-1. The instrument design is compact (1.0kg in air). Infinity EM allows for current velocity measurements virtually anywhere.
-
Product
CATV Separate Raman Amplifier
RFA4000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Amplifier is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. Raman amplifier is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.
-
Product
Physical Contact Connectors
-
Amphenol Fiber Systems International
Physical Contact (PC) connections are characterized by the physical mating of two optical fibers. Precision ceramic ferrules are typically utilized for PC connections. A PC connection is accomplished by terminating the optical fiber into a precision ceramic ferrule. Epoxy is used to affix the fiber into the ferrule. The tip of the ceramic ferrule is polished in a precise manner to ensure that light enters and exits at a known trajectory with little scattering or optical loss. Polishing the terminated ceramic ferrule is a critical process in Physical Contact fiber optic connectors.
-
Product
Vector Network Analyzer
-
SIGLENT Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, with 2/4-port models that can quickly deliver reliable scattering, differential, and time-domain parameter measurements.
-
Product
Scattering Sensors
-
Scattering sensor data offers links to particulate bigeochemistry and ocean color. Sea-Bird Scientific offers a wide variety of scattering sensor configurations and measurement capabilities. Our sensors are available in single, dual, and three-measurement combinations.
-
Product
Omnisens Optical Fiber And Cable Measurement And Quality Control
https://www.omnisens.com/uploads/1/2/0/5/120592129/telecom-1_orig.png
-
To provide quality control or help with the design and testing of fibers, Omnisens Vision offers fast, accurate strain and temperature measurements.Omnisens Vision is based on Brillouin scattering. In single mode fibers it produces precision readings with high spatial resolution over long distances and/or large loss test conditions. It is capable of high speed testing in dynamic situations such as flex fatigue.Its configuration flexibility makes the Omnisens Vision well adapted to a wide variety of test & measurement needs.
-
Product
Laser Particle Size Analyzer
Easysizer20
-
Zhengzhou Nanbei Instrument Equipment Co. Ltd
sysizer20 is the latest product of OMEC in Year 2006 and is highly automated, all the process can be done automatically after setting up initial parameters. Multiple sample feeding systems are available to meet your requirements. Applications:Measure the particle size distribution of powder or latex Principle:Use the principle of laser light scattering to determine particle size distribution.
-
Product
Optical Time Domain Reflectometers
-
An optical time domain reflectometer (OTDR) is a precision instrument used to locate events or faults along a fiber link, typically within an optical communications network. The OTDR launches a series of high speed optical pulses into the fiber to be measured. Various events on the fiber generates a Rayleigh back scatter that returns to the OTDR and the strength of the return pulses are measured and integrated as a function of time, and plotted as a function of fiber length. The horizontal axis is the distance and the vertical axis is the loss.
-
Product
Light-resistant Integrating Sphere
-
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
Product
High-efficiency Fiber Stretcher
PZ2
-
The PZ2 provides the most extensive stretch of our stretcher product family. It is a fiber wound piezoelectric element for use in a wide range of optical interferometric measurement and sensing system applications. Typical uses include open loop demodulation, sensor simulation, white-light scanning interferometry and large angle modulation of interferometric phase. The PZ2 is ideal for use in OCT [Optical Coherence Tomography] and OCDR [Optical Coherence Domain Reflectometry] applications requiring scattering or boundary definition measurements.
-
Product
UltraScan VIS Spectrophotometer
Spectrometer
Hunter Associates Laboratory, Inc.
The UltraScan VIS easily measures both reflected and transmitted color as well as transmission haze and meets CIE, ASTM and USP guidelines for accurate color measurement. UltraScan VIS uses diffuse/8° geometry with automated specular component inclusion/exclusion. For transmission measurement, the use of a robust CIE-conforming sphere instrument (TTRAN Total Transmission mode) effectively negates the effects of minor scattering typically found in transparent samples.
-
Product
Multi-Laser Nanoparticle Tracking Analysis (NTA)
ViewSizer 3000
-
Exosomes, viruses, and nanoparticles all have wide size distributions which defeat traditional Nanoparticle Tracking Analysis (NTA) analyzers. The ViewSizer 3000 features simultaneous measurement with three lasers to collect the most accurate distribution and concentration information over a wide range of sizes within the same sample. Where the signal from a particle is too bright and saturates the detector from one laser, the software automatically uses data from a lower power laser to ensure the most accurate size and concentration information. On the other hand, when scattering from one laser is too weak for detection, the software uses data from a higher power laser to accurately track the particle.
-
Product
Bending Deflectometers For ISO 178, JIS K 7171, And ASTM D790 Compliant Testing
-
After tensile testing, flexural tests are the most common strength tests for plastics and other resins. The main standards for plastic flexural (bend) tests are ISO 178, JIS K 7171, and ASTM D790, which require very accurate test systems. These standards include flexural strain measurements using a deflectometer, ranging from micro-strain measurements in the elastic region, the reversible elongation at the beginning of tests, to larger strain measurements in the plastic region. Shimadzu's deflectometers integrate easily into AG-X plus series, AGS-X series, and EZ-X test frames and Trapezium X testing software. Since these deflectometers push up against the specimen from below, the specimen color is not a limiting factor, as can be for laser type non-contact deflectometers. Furthermore, these deflectometers can partially absorb the shock during specimen failure, preventing specimen fragments from scattering.
-
Product
Fusion Splicer
-
Shaanxi Aitelong Technology Co., Ltd
Fusion splicing is the act of joining two optical fibers end-to-end. The goal is to fuse the two fibers together in such a way that light passing through the fibers is not scattered or reflected back by the splice, and so that the splice and the region surrounding it are almost as strong as the intact fiber.
-
Product
Static Multiple Light Scattering (SMLS)
TURBISCAN
-
Static Multiple Light Scattering (SMLS) is an optical method that allows for the direct characterization of native concentrated liquid dispersions. Microtrac’s TURBISCAN range uses this technology to provide accurate and rapid results. TURBISCAN was the first patented technology to provide tools that allow accelerated aging tests on unstressed products, thus becoming a reference for direct stability characterization technology.
-
Product
Isolators
-
Optical isolators transmit light in only one direction. These devices are especially beneficial in preventing back-reflection and scattered light from reaching sensitive components such as lasers.
-
Product
Multi-angle Polarized Light Scattering Measurements
LISST-VSF
-
The LISST-VSF covers the angular range from 0.094 to 150°. Of this, the range 0.094 to 14.9° is covered with Sequoia’s 32-ring detector optics as in the LISST-200X. From 15 to 150° scattering from the length of a laser is viewed by a rotating eyeball. These data produce P12 and a noisy estimate of P22 (no P22 estimate at 45 and 135°).
-
Product
Particle Size Analyzers
NanoBrook Series
-
Brookhaven Instruments Corporation
Rapid and accurate protein & nanoparticle size distributionsMultimodal & unimodal size distribution softwareISO 13321 and ISO 22412 compliant resultsRange: < 0.3 nm to 10 mThree measurement angles: 15, 90, and 173Ideal for fast, routine sizing applications in research or quality controlHigh power 35 mW diode laserDynamic light scattering at 173 and 90Temperature control, -5 C to 110 CCompact bench top unit, USB connectionMolecular weight determination (relative and absolute through Debye plot)
-
Product
SERS (Surface Enhanced Raman Scattering) Substrate & SERS Reader – Mini Chemistry Analytic Pack
-
The porous carbon SERS substrate provides not only high signal enhancement due to its strong broadband charge-transfer resonance for large chemical enhancement (as opposed to electromagnetic enhancement in traditional metal-based SERS substrates), but also extraordinarily high reproducibility or substrate-to-substrate, spot-to-spot, sample-to-sample, and time-to-time consistency in SERS spectrum (which is not possible with traditional metal-based SERS) due to the absence of "electromagnetic hot spots" by making the entire surface of the substrate "chemically hot", high durability due to no oxidization, and high compatibility to biomolecules due to its fluorescence quenching capability.