Filter Results By:
Products
Applications
Manufacturers
Additive White Gaussian Noise
-
product
Dual Output AWGN Generator Line Module
458-AWGN2
The Model 458-AWGN2 is the ideal solution for injecting Additive White Gaussian Noise (AWGN) for ADSL, ADSL2, ADSL2+, and VDSL2 chip/modem/DSLAM testing applications.
-
product
RF Noise Source
NS-3
The NS-3 Broadband RF Noise Generator provides an extremely flat AWGN (Additive White Gaussian Noise) signal from 5 to 2150 MHz. The output level adjusts in 0.1 dB steps over a 30 dB range.The bench-top configuration is standard and an optional two unit rack enclosure is available. The RS232 or USB remote control interface simplifies its use in automated test and factory ATE environments. The NS-3's combination of range, versatility and value make it the ideal general purpose broad-spectrum signal source for bench and ATE applications, including C/N, BER, MER, PER testing and rain fade simulation.
-
product
Polymer Additives Library
The analysis of additives contained in polymer materials is essential for managing and improving the quality of these materials, and for complying with regulations dealing with chemical substances. The Polymer Additives Library is a GCMS mass spectral library containing information on a wide range of additives utilized in polymer materials.
-
product
Gaussian Optics Lens Antennas
SAG-1441544002-06-S1
Gaussian optics lens antennas are offered with either a circular or rectangular waveguide interface. While Gaussian optics lens antennas with a rectangular waveguide interface can only support linear polarization, models with a circular waveguide interface can support various polarization types including horizontal, vertical, left-handed circular, and right-handed circular polarization for broader applications. Gaussian optics lens antennas are designed and constructed to offer high efficiency, low side lobes and a rugged mechanical configuration. A corrugated feed horn and dielectric lens allow these antennas to form well-defined Gaussian beams. Additionally, the dielectric lens provides phase error corrections and serves as a radome to protect from environmental conditions.
-
product
Noise Sources
WGNS
The system allows the user to extend the frequency range of the NFA to allow for accurate noise figure measurements to be performed on a device operating in the 26.5 – 170GHz range on wafer as well as in benchtop applications. Farran offers the WGNS series of noise sources to be used in conjunction with the FBC down converters for use as frequency extenders for noise figure measurement test system.
-
product
Noise Sources
NC1128A
This noise source by Noisecom produces white Gaussian noise up to +13 dBm. It contains a hermetically packaged noise diode that has been pre-selected for special performance characteristics. This module is ideal for many different applications including CATV, Secure communications, Jamming systems, OC-192 Testing, EW & EC.
-
product
Noise Receiver Modules And Noise Switching Modules
MT7553 Series
Noise Parameters are the non-50Ω extensions of Noise Figure, and are an important modeling and model validation tool to understand how a device-undertest’s performance changes as a function of source impedance. Noise Parameter measurements are typically performedusing a Vector Network Analyzer (VNA) to measure the S-Parameters of the DUT, and a Noise Analyzer (either Noise Figure Analyzer NFA or Spectrum Analyzer SA) to measure the noise power of the DUT. Noise parameters are calculated from a combination of knownsource impedances, S-parameters and noise powers.
-
product
Noise Test
Noise testing is conducted to determine if materials can withstand external noises generated by various sources. It also includes air-borne and structure-borne noise measurements.
-
product
Noise Dosimeter
ASV5910-3
Hangzhou Aihua Instruments Co., Ltd.
*Attractivedesign, mini—sized and weighs only 85g*Modulardesign, cable—free and dual channels*Complywith IEC61672, IEC61252 and ANSI S1.25*Rechargeable lithium polymer battery*Softwarepackage, downloads to PC*Varietymounting methods
-
product
Noise Dosimeters
Noise Dosimeters are wearable, portable, wireless (cable-free), personal noise exposure meters for occupational and workplace noise measurements. They are designed specifically to monitor an employee’s noise exposure in order to comply with Health and Safety regulations.
-
product
Noise Thermometer
MFFT-1
The MFFT-1 magnetic field fluctuation thermometer is a high accuracy thermometer system for typical dilution refrigerator temperature ranges.
-
product
Noise Dosimeter
doseBadge5
The doseBadge5 is the next generation doseBadge noise dosimeter from Cirrus. It provides all of the unique features of the original doseBadge such as no controls, cables or displays with a range of new functions and features allowing it to be used for compliance with any occupational noise standard. Wireless communication to the dBLink App (for Android and iOS) or the doseBadge5 Wand allows the instrument to be configured and controlled without user intervention. Measurements can be scheduled to start, pause and stop automatically with the timer functions allowing the doseBadge5 to be deployed quickly and easily.
-
product
Noise and Vibration Testing
Electronic Systems of Wisconsin, Inc.
ESW's unique Noise & Vibration Test Systems come fully equipped with the latest industry features. The on-screen operator display in our testers make it easy to set-up, read, track and record your noise or vibration information. We work directly with you to determine the best solution that will work for your application. Our data logging make sure that important data is stored and available for download for future reference. ESW's design engineers work to make sure the testing interface is easy for your operators to use. We work closely with our customers to make sure that your unique testing needs are met. Please see the slideshow below to see some of our Noise & Vibration Testers.
-
product
Phase Noise Analyzers
Holzworth Instrumentation, Inc.
Holzworth's Real Time Phase Noise Analyzers are each designed to provide data faster than any other system, while maintaining data accuracy and repeatibilty. There is no guess work as to whether results are valid to the DUT or if there are unwanted variations or contributions coming from the measurement system itself.
-
product
Noise Monitoring System
NoiseTutor
Continuous monitoring of environmental data in remote areas has always presented a unique set of challenges. Typical solutions involve complex installations, frequent visits to remote locations to keep the system fully operational and require expert level attention to retrieve and share data amongst customers, consultants and project leads.
-
product
Low Noise Amplifier
Low noise amplifier with a typical small signal gain of 22 dB and a nominal noise figure of 5dB across the frequencyrange of 90 to 110 GHz.
-
product
Noise Monitoring
Larson Davis provides complete solutions for noise and vibration measurement and analysis. From stand-alone, simple-to-use instruments to complete systems including sensors, data acquisition, and software, Larson Davis has what you need.
-
product
Phase Noise Analyzer
DCNTS
Noise eXtended Technologies S.A.S.
The DCNTS is a two channel Phase and Amplitude noise analyzer. Its dual demodulator architecture allows the system to use cross-correlation to cancel its internal noise and limitation; it is like comparing the outputs of 2 systems and only display the similarities while rejecting differences.
-
product
Antenna Noise Canceller
ANC-4
The ANC-4 is an rf device that eliminates or reduces power line noise, BPL noise, computer noise, TV-generated interference, and other types of electrical noise. The ANC-4 unit connects right to the antenna connector of the receiver or transceiver to cancel locally generated noise before it gets into the receiver and affects the receiver AGC circuits.
-
product
Noise Generators
GShM Series
*Operating temperature: +15...+25°C*Detection error for excessive relative noise temperature: +/-0.4 dB*Power consumption — <35 mA
-
product
Low Noise Amplifier
Corech Microwave’s Low Noise Amplifier(LNA) frequency ranges from 1kHz to 67 GHz, featured with ultra low noise figure, high gain and compact size. Narrow-band & wide-band ready modules are available. Output power from +1dBm to +18dBm. 2.92mm – F, PIN, and SMA – F connector options are available.
-
product
Low Noise Amplifiers
Our range of ITAR Free, Low Noise Amplifiers (LNAs) cover a variety of applications but are primarily suited to airborne, maritime and ground based radar systems. LNAs are primarily intended to minimise added noise whilst providing high gain so design focusses on the parameters associated with the noise response of the amplifier. They are usually the first amplifier in the Radar detection chain and will have the lowest noise figure.
-
product
Minimal Signal Noise
SCSI Quiet Cables
Paralan Corporation was one of the first companies to recognize that 90% of the problems with SCSI Bus installations lie with the cables. To address this problem, Paralan developed its own line of high-quality shielded Quiet Cables.
-
product
USB TESTER, 3-9V, 3A, WHITE
72-13540
*USB tester inspects USB charger & portable power source*Lightweight and portable*LCD backlight*High/low output voltage warning*10 sets of data memory
-
product
Noise Location Package
Type HFDF
National RF’s Type HFDF high frequency location system is a proven noise hunting and location directional antenna system that allows you, in many cases, to walk right up to the source of High Frequency (HF) noise! Used by several power companies around the United States, professional noise hunters, and other communications specialists, the HFDF has located noise sources that emanated from pole power transformers, arcing electric fences, CATV in-line amplifiers, plasma TV screens, and even Marijuana grower’s heating lamps! The system incorporates several plug-in, tunable magnetic loop sensors of a proprietary National RF design, that cover the frequency range between 1.8 MHz and 55 MHz. The unit is packaged in a hand-held, lightweight metallic enclosure, with a pistol grip and a magnetic compass mounted on top. The compass is used to get magnetic bearings to the noise source, which may be plotted on a map to triangulate, and ultimately pin-point, the location of the noise source. In certain cases, our customers tell us that they have been able to walk right up to the interfering noise source and correct the situation on the spot!
-
product
Noise Source
MNS-1
Matrix Test Equipment Incorporated
The MNS-1 is a shaped noise source that can be used toemulate 2 bands of digital carriers. While it does not havethe necessary attributes to generate a constellation, it doesmimic the loading of QAM carriers. The MNS-2 featuresremotely controllable 6 MHz wide notch filters to allowintroducing a QAM carrier capable of generating a constellationand enabling measurement of Modulation Error Ratio (MER) andBit Error Rate (BER).
-
product
Noise Source Family
347
The R347B waveguide noise source cover the R-band (26.5 to 40 GHz frequency range), while the Q347B model cover the Q-band (33 to 50 GHz frequency range), allows you to make accurate noise figure measurements on millimeter-wave devices.





























