Working Standards
-
Product
Capacitive H.V. Detectors (Contact)
213 HVD~226 HVD
-
Standard Electric Works Co., Ltd
Excellent shock resistance. Rugged nylon moulding. Auto on (when voltage detected). Excellent drop resistance. Good vibration resistance. Loud sound alarm indication. Built-in proving and self-test circuit. High bright color-coded LEDS. Works from standard 9V battery. Interchangeable contact electrode. Use in all whether conditions. Compatible with all link sticks. Lightweight, robust & compact. Models available from 11kV to 132kV. Suitable for indoor and outdoor use. Self(auto on) or manual arming. Easy access to batteries. Customized threshold on demand. Auto off (if no voltage detected). Waterproof design, protection class : IP65.
-
Product
Decade Box, Calibrated W/D & U, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL DU
-
The 72-7270 CAL DU from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Working Standard Shunts
CSW
-
CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.
-
Product
Portable Microscope With XY Stage, X150 2mm Field Of View
-
*Veterinary Worm Egg Counting*Counting of algae and other samples*Easy positioning of the sample*Methodically scanning of slides and counting chambers*Works with standard microscope slides and counting chambers (25x75mm or 1”x2”) and with 32mm wide counting chambers*Allows manual movement of the slide and counting chamber independently in the left-right (X) axis and front-back (Y) axis
-
Product
Decade Box, Calibrated W/Data, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL D
-
The 72-7270 CAL D from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Decade Box, Calibrated W/D & U, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL DU
-
The 72-7265 CAL DU from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Instruments Transformers Tester
Calport 100 Plus
-
Calmet Smart Calibration Devices
Three phase instrument transformers and electricity meters tester class 0.1 or 0.2. It makes possible CT and PT testing on site or in the laboratory. We recommend a new replacement - TE30 Working Standard
-
Product
USB 3.0 Cameras
See3CAM
-
See3CAM - a new series of USB 3.0 Camera. It's the world's first UVC compliant USB 3.0 Camera Module that is plug & play on Windows/Linux. USB 3.0 camera board does not require additional device drivers. These USB3 cameras work with standard Windows (DirectShow) and Linux (V4L2) software. USB3 Camera is based on Aptina & OmniVision CMOS sensors.
-
Product
Telecom Test Systems
4301 Series
-
The 4301 is designed to work with a standard arbitrary wave form generator or signal source that can be triggered. The system can be ordered with an optional Fluke 281 arbitrary waveform generator, which comes pre-programmed and integrated into the 4301 system. When equipped with the Fluke 281 option, the 4301 provides a complete solution for GR-1089 Section 10/ATIS-0600315.2007 testing.
-
Product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
-
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Absorber Lined Shielding Enclosure Measurements
ALSE
-
Due to on-going work in the standardization committee CISPR D (responsible for CISPR 25) the latest issue CISPR 25 Ed. 4.0 has not been cited to-date. In the meantime we are able to offer two different validation procedures:
-
Product
Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
-
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Geometry
-
Our glass and coating geometry test instruments ensure fiber performance and adherence to telecom standards. Our solutions are capable of measuring diameter, circularity, and concentricity for both coatings and glass plus fiber curl. Our flexible geometry measurement systems not only work with standard telecom fibers, but are continually updated to meet new requirements, such as PM, multicore and hollow-core fibers.
-
Product
Primary Standard Capacitors
GenRad 1404 Series
-
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
Product
Micro-Ohmmeter Calibration Kit
LOM-530
-
The LOM-530 is convenient single unit containing a complete set of (5) working standard grade resistors for complete calibration of micro-ohmmeters. The standard resistance values are those used by the LOM-510A Microohmmeter/Milliohmmeter.
-
Product
Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL
-
The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Multi Output Buffer Unit
MS 1632
-
The Multi Output Buffer Unit is used for driving singe input to 32 outputs. This unit drives an analog input to two different 16 set of outputs through two 50 Pin standard D Type connector. The unit works on standard 230V AC.
-
Product
Experimental Techniques
-
Most Linkam stages work with all standard microscopy setups, but did you know that Linkam’s temperature and environmental control systems can be used for, and with, a wide range of experimental techniques?
-
Product
Open Standard Module (OSM)
ROM-2820
Open Standard Module
Advantech ROM-2820 OSM 1.1 Computer-on-Module is powered by NXP i.MX 93 SoC which includes Cortex-A55 Dual-core in combination with one Cortex-M33 real time processor, Ethos®-U65 Neural Processing Unit (NPU) and 2D graphics engine. It provides USB2.0, Gigabit Ethernet, MIPI-CSI, I2C, SPI, GPIO, CAN-FD and MIPI DSI display for embedded applications
-
Product
Standard Connectors
-
C.C.P. Contact Probes Co., LTD.
The Standard Connector Series aims to offer a comprehensive selection of internationallycompatible connectors. Its smart design and simple structure makes it very cost effectiveeven at small volumes.
-
Product
Capacitance Standard
SCA Series
-
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
Product
Standard CW Amplifiers
-
An electronic device that boosts radio frequency (RF) or optical signals while maintaining an uninterrupted, constant output waveform.
-
Product
Safety Network (AS-i Safety at Work)
-
*Monitoring of up to 31 safe AS-i slaves*Applications: door monitoring, light curtains, e-stop, two-hand control*Safe AS-i modules for field applications and control cabinets*Safe AS-i door switches with guard locking and guard lock monitoring
-
Product
Standard CT
6300A
-
The Model 2509 Instrument Current Transformer is a 6300 A ampere CT designed for precision measurement of AC current or for Instrument Current Transformer calibration applications. The CT can be installed on a bus bar or it can be used with a primary conductor consisting of number of turns. The 6300 CT is designed with a tapped primary & a tapped secondary winding, thus providing a large number of ratios over a range of 5 to 6300 amperes.
-
Product
Nanoscale Microscopy Standards
-
The nanoscale AFM-CD standard (CD, critical dimension) contains structures to calibrate line widths and periods of AFM (atomic force microscopy) devices.
-
Product
Standard Helmholtz Coils
-
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
Product
Standard Test Devices
-
Zhengzhou SMS Electric Co.,Ltd
Fast, accurate verification to ensure that all devices work reliably.
-
Product
Standard Systems With Customization
-
When the cable assembly product offerings on the website – cable, connectors, and markers – do not meet the needs of your application, Teledyne Storm Microwave provides our Standard with Features (SWF) offering. SWF allows the customization of your cable assembly needs by discussing your needs with our Applications Engineering professionals and without needing a detailed specification.