Laser Light Sources
-
Product
Laser Source
TW3104
-
Techwin(China) Industry Co., Ltd
Laser Source TW3104 is an essential instrument for optical network installation, trouble shooting and maintenance which can be used with an optical power meter for measuring optical loss in single-mode or multi-mode fiber cables. TW3104 is the earliest light source model in Techwin. It features compact size, high output power, stable output power and excellent wavelength stability .
-
Product
Broadband Optical Source - MATRIQ
Optical Source
Our SLED MATRIQ instrument is a compact super-luminescent LED light source with high output power, large bandwidth and low spectral ripple.The SLED comes in various wavelength models to address various key applications across telecom and datacom, and is ideal for building a customized optical testing platform that delivers reliable and repeatable results.
-
Product
Light Sources
-
For applications such as transmission, absorption, and reflection, illumination sources are needed. Avantes offers a wide range of different types of light sources, to suit your specific application needs. An overview of the different types of light sources can be found below.
-
Product
PXIe-4142, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit
782430-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit - The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
Light Sources
-
There are many low cost artificial light sources used for illumination or for industrial applications: tungsten or halogen bulbs, fluorescent lamps, LED lamps etc. Some of these sources have regulated intensity of emitted light. However, there very few calibrated light sources of precisely known parameters. A light source can be considered as calibrated when its user can precisely regulate its photometric/radiometric parameters like luminance (or illuminance), radiance (or irradiance) at defined spectrum of interest. Such light sources are needed in many applications among them, in systems for testing night vision devices, VIS-NIR cameras and SWIR imagers. Inframet offers a series of calibrated light sources that can be divides into three groups:
-
Product
Source Measurement Unit
DPS16
Source Measure Unit
The DPS16 offers high voltage DPS in a compact, 3U PXI form factor. The DPS16 supports 0V to +4V 0.3A or 0V to 12V 25.6mA with FVMI, FVMV, FIMV, FIMI modes. 16 channel can be ganged to support high current driving.
-
Product
Source Measurement Unit
PEMU4
Source Measure Unit
The PEMU4 represents a new level of performance and capabilities for USB-based SMU (Source MeasurementUnit) instrumentation. The PEMU4 supports -1V to +6.5V 0.5A with FVMI, FVMV, FIMV, FIMI modes. 4 channel can be ganged to support high current driving. I2C/SPI/RFFE function for serial port device testing. 4 Counter for frequency measurement.
-
Product
Source Measurement Unit
SMU4
Source Measure Unit
The SMU4 offers high voltage DPS in a compact, 3U PXI form factor. The SMU4 supports -20V to +20V 100mA with FVMI, FVMV, FIMV, FIMI modes.
-
Product
Calibration Light Source
CAL1
-
Image Engineering GmbH & Co. KG
The one light source solution in the field of camera characterization and calibration. CAL1The CAL1 calibration light source is designed to characterize and calibrate cameras in the lab or on the production line. Its compact design consists of one iQ-LED element in a 0.3 m integrating sphere that illuminates a 70 mm opening. Because of the non-reflective special diffusor filter on the sphere opening, a uniformity of more than 98% could be reached
-
Product
Light Source
FiberPal OT-3000
-
The OT-3220/3221 is designed for a high performance stabilized laser source, especially in practice for FTTX networking installation and maintenance fieldworks environment requirements. It is usually applied as stable laser sources for wide range of optical testers and tools in optical fiber cabling and transmission systems.
-
Product
Noise Source, 1 GHz up to 40 GHz
346CK40
Noise Source
The Keysight 346CK40 is the ideal companion to Keysight´s noise figure solutions when working on high frequency applications. Since it is broadband (1 GHz to 40 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source greatly reduces measurement uncertainty, which are commonly reflections of the test signals. This is a coaxial noise source with a 2.4 mm coaxial connector. ENR typically 14 dB at 1 GHz, decreasing to 5 dB at 40 GHz (typical).
-
Product
Light Source
-
OrienTek Optical Technology Ltd.
High PrecisionHighly accurate unit offering 6 calibrated wavelengthsInterchangeable connectorsDurable and reliable designEasy-to-use interface forerror-free testingRubber armor protection
-
Product
Single-Port Tunable Laser System Source
N7711A
Laser Source
The Keysight N7711A and N7714A tunable lasers are single-port and four-port sources, available with C-band or L-band wavelength coverage. The narrow linewidth and offset grid fine-tuning capability make them ideal sources for realistic loading of the latest transmission systems. All models can reach any wavelength point within their specified wavelength range just like all other Keysight tunable lasers. In this mode, code compatibility with existing test setups based on Keysight's range of full-size and compact tunable lasers is a great asset. In system loading applications, it may be preferable to grid-tune the lasers like system transmitters, simply by changing the channel index. The channel grid is adjustable to standard ITU-T grid spacing like 50 GHz, and to arbitrary grids. Likewise, the zero frequency (base channel) of the chosen grid is adjustable. A 12 GHz fine-tuning range allows de-tuning the frequency.
-
Product
Laser Sources and Amplifiers
Amplifier
We design and manufacture a range of tunable C-band and L-band telecom laser sources, customizable fixed-wavelength laser sources, broadband super luminescent (SLED) sources, swept laser sources, and Erbium-Doped Fiber Amplifiers (EDFA).
-
Product
Forensic Light Source
HandScope LASER
-
The new HandScope LASER is the latest Forensic Light Source by SPEX Forensics. The unique design allows one-hand operation. The same hand holding the light source can change cycle through the four different wavelengths and three power settings using the LCD touch panel. No other Laser offers the same versatility.
-
Product
Light Source
UVF-210S
-
By traversing two light guide ends (right and left) by means of the high accuracy air cylinder, alternating irradiation of two independent positions is possible.
-
Product
PXIe-4140, 4-Channel Source Measure Unit
781742-01
Source Measure Unit
The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4140 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
Portable Light Sources
FOD 2113
-
The FOD 2113 provides three wavelengths: 1310&1550 nm in one port and 850 nm 10mW in another port. Available adapter types: FC, SC, ST, Universal 2.5mm. All adapters are changeable
-
Product
Light Source Series
-
High output powerStable and reliableCW or MOD outputMOD frequency: 270Hz/1KHz/2KHzSMT, lightweightPower supply by battery
-
Product
Four-Wavelength Laser Source
CA6017 Series
-
The CA6017 Can transmit with a wavelength-identification digital encrypted protocol, enabling the FHP2 power meter to automatically use the proper calibration wavelength. This feature reduces the need for communication between the two technicians and decreases the possibility of making mistakes
-
Product
Optical Light Source
CARY-LS300B
-
The CARY-LS300B optical light source provide 1310/1490/1550 nm three outputwavelengths to meet specific application requirements. It is a idea solution for the fiberoptic network characterization, out-door network construction inspection and lab application.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers
-
Product
Light Source
pE-300ultra
-
CoolLED's pE-300ultrais a fluorescence microscopy light source which offers intense, broad-spectrum LED illumination for imaging most common fluorescent stains. Users have access to both microsecond switching via multiple TTL inputs and the ability to mount inline excitation filters. This, when paired with today's high performance multi band filter sets, facilitates imaging traditionally done via a white light source and a filter wheel, with all the benefits of LED.
-
Product
Handheld Optical Light Source
JW3111
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3111 optical light source is a handheld optical light source, newly released in 2007. It can provide 1 to 6 wavelengths output to satisfy specific requirements including the 650nm visible light source and the 1310/1550nm wavelengths for single mode fiber or the 850/1300nm wavelengths for multimode fiber, as well as other wavelengths according to customer’s needs. Together with the JW3211 optical power meter, it is a perfect solution for fiber optic network applications.
-
Product
Mini Light Source Meter
MLS-100
-
•Stabilized Light Source•1310nm & 1550nm•Very small and lightweight•Controlled by Smartphone or PC via USB or Bluetooth•Smartphone application software and PC software•Li-ion Polymer Rechargeable battery•Battery charging via a USB interface•Universal 2.5mm adapter to accept FC, SC or ST•Reference light source for optical test
-
Product
Laser Head
5517C
Laser Head
The Keysight 5517C is used primarily in VME and PC based laser interferometer systems where the velocity of motion is faster, such as semiconductor lithography and flat panel applications. Option 009 allows a larger angular range of measurement by providing a 9 mm beam diameter for use with three-axis interferometers. Please contact Keysight for custom requirements.
-
Product
Supercontinuum White Light Lasers
SuperK series
-
The SuperK series is an industry-leading range of turn-key supercontinuum white light lasers used by the most innovative companies within bio-imaging, semiconductor inspection, sorting, device characterization, and scientific instrumentation. The sources are robust and reliable, built for intensive use, and can replace multiple single-line lasers as well as broadband sources like ASE sources, SLEDs and lamps.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
Source Measure Unit
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
Millimeter-Wave Noise Source, Q-band, 33 To 50 GHz
Q347B
Noise Source
The Q347B waveguide noise source (33 to 50 GHz frequency range), allows you to make accurate noise figure measurements on millimeter-wave devices...