Pulse Current
-
Product
Split type Pulse Current Sensor
PCT-06
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Through hole type pulse current sensor.*Pulse current sensor for power demand meter.
-
Product
Split type Pulse Current Sensor
CTF-05M
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Pulse current detection for power demand meter.*Through hole type CT.*Open collector output.
-
Product
Split type Pulse Current Sensor
OKM-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For pulse current detection.
-
Product
Split type Pulse Current Sensor
CTF-05T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For detecting current pulse with open collector output (for power pulse)
-
Product
Split type Pulse Current Sensor
CTF-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Suitable for the operation and cable continuity check of the equipment by pulse current detection method. Wide AC current range from 0.1mA to 8A. Ultra compact and light weight. High sensitivity and least affection from external magnetic field.
-
Product
DC Pulse Current Capacitor
-
Both series can be customized as Low Voltage High Capacitance High Current Capacitors.We can customize Snubber Capacitor as Box type and support other parameters.For 250Vac~900Vac / 400Vdc~1,350Vdc and with higher Current requirement, please refer to our AC/DC Power Capacitors.Different applications can have very different capacitor electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
Modular Laser Diode Test System (PXI/PXIe)
LTS8620
-
The LTS8620 test system is a modular PXI test system for testing and qualifying laser diodes. The system is able to generate extremely short current pulses. This minimizes the effects of heat on the laser diode.
-
Product
Milliohm Meter
16502
-
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
Product
Precision Pulsed Current Sources
SpikeSafe Performance Series
-
SpikeSafe™ Performance Series Current Sources supply DC and precision continuous or single pulse current for light measurement and other applications. With sustained output power and no duty cycle limitations, Performance Series Current Sources support a broad range of applications.
-
Product
Reflectometer
T-510
-
Techno Instrumentation (India) Private Limited
Pulse Echo, Impulse current and Decay methodprovided to get the distance to almost all typesof faults.Laptop based 15 inch display with user friendlyinterface for easy operation.Online support of experts to review fault graphs.Comparison feature of any 5 graphs for reviewand analysis to get more accurate results.Velocity of propogation(VOP) control makes iteasy to precisely pre-locate faults in cables withdifferent velocity.Automatic storage of more than 10,000 faultgraphs.
-
Product
AC/DC Power Capacitors
ACF Series
-
For 70Vac~400Vac / 100Vdc~700Vdc Pulse Current requirement, please refer to our DC Pulse Current Capacitors for Power Electronic applications.For continuous and High RMS Current requirement, please refer to our High AC Current Capacitors LC series, which support continuous duty even at +105C.We manufacture AC Filter Capacitors for a wide variety of applications with different Capacitances, Voltages, Discharge Energy ranges, dv/dt, Pulse Discharge Currents, RMS Currents, frequency ranges, size restriction and even capacitor mountings.
-
Product
High Current SMU 600/1200/2400 A
AXC85xx
-
Generate extremely short, fully regulated current pulses in 4 ranges. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.
-
Product
8 Channel Portable Data Acquisition Logger w/ 5" Touchscreen
Titan S8
-
The Titan S8 portable data acquisition logger combines industrial toughness with scientific accuracy to create a powerful, versatile standalone logger. In any environment, from the laboratory to the factory floor, the Titan S8 simplifies complex validation tasks with its eight input channels and a full-color, user-friendly touchscreen interface. No matter the task, the Titan S8 brings valuable, real-time temperature, pulse, current, and voltage data to users’ fingertips without any need for a PC. The Titan S8 is the ultimate companion for any service, equipment, or compliance engineer. Its handheld portability and shock absorbing boot empower users to bring powerful, instantaneous data acquisition wherever it is needed.
-
Product
Counter And Rate Meters
-
We carry a wide range of counter and rate meters including totalizers, batch controllers, and more. Available with pulse, magnetic or DC pulse, analog, voltage, current, and frequency input types.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-600B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Potential Meters
-
Potential meters are basically electrometers which have extremely high input resistances in order to keep the feeding reference electrode free of load. This is necessary to maintain the true potential. pH - meters can be used as potential meters when fast reading is not required, because common pH meters are very slow. When the potential answer to current pulses is to be followed, potential meters are essential.
-
Product
120 A High Voltage 50 Ω Pulse Generator
TLP-12010C
-
High Power Pulse Instruments GmbH
- High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
Product
Condenser for General Applications
PECA1
-
Lifasa - International Capacitors, SA
These capacitors are designed for application in circuits in which they are subjected to non-sinusoidal voltages and pulsed currents, such as, for example, switching and damping circuits. They can also be used as discharge and filtering capacitors, as well as for any DC application. This capacitor is especially suitable for applications in which a high life expectancy is required.
-
Product
Transmission Line Pulse Testing
-
Transmission Line Pulse testing, or TLP testing, is a method for semiconductor characterization of Electrostatic Discharge (ESD) protection structures. In the Transmission Line Pulse test, high current pulses are applied to the pin under test (PUT) at successively higher levels through a coaxial cable of specified length. The applied pulses are of a current amplitude and duration representative of the Human Body Model (HBM) event (or a Charged Device Model – CDM – event in the case of Very Fast TLP, or VF-TLP).
-
Product
Power Sources
MS-Series
-
The MS-Series Power Sources are high performance, high efficiency, AC to AC converters. Rugged powerful output provides up to 350 amps of pulse current for driving non-linear loads.
-
Product
Direct Current Measurement Card
LQI5
-
Computer Gesteuerte Systeme GmbH
The LQI5 is a precision direct current measurement card. It features 6 measurement ranges for unipolar current measurements of up to 32 A. Current pulses shorter than 5 seconds can be measured up to 65 A.
-
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20LSP-0.6S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
Product
IC Side Channel Analysis
-
These probes allow you to couple fast, transient magnetic field, E-field, and current pulses into ICs.
-
Product
High Voltage Film Capacitor
STHVP/STHVE
-
High Voltage Pulse Current for medium frequency applicationHigh Voltage DC / AC Voltage applicationCapacitor can be discharged at rated voltage directly without any protective component and with ambient Temperature up to +105CHigh Voltage Decoupling and SnubberingVoltage MultiplierInduction heatingAct as discharge capacitor to trigger laser, X-Ray and Tesla CoilFor high voltage capacitor bank or arrayHigh Voltage Power Supplies
-
Product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
Product
Low Inductance BNC Cable, VOLT:DC 60V
PX0105A
Coaxial Cable
The Keysight PX0105A is suitable for narrow current pulse measurement down to 10 μs pulse width. It supports the Keysight M9602/03A.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
Product
High Voltage 50 Ω Pulse Generator
TLP-8010A
-
High Power Pulse Instruments GmbH
*Wafer and package level TLP/HMM testing*Fast 50 Ω high voltage pulse output with typical 300 ps rise time*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω-configuration*High pulse output current up to ±80 A (short circuit) with 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 300 ps to 50 ns*1 built-in pulse width: 100 ns*Optional external pulse width extensions 5/10/50/100/200/500 ns using an external pulse width extender TLP-8012A5*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components





























