Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
PXI-2597, 26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module
778572-97
RF Multiplexer
26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2597 is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. The internal termination of the PXI‑2597 helps prevent high-power reflections that arise from open channels on the module. You can use the PXI‑2597 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
BNC To Ferrule Terminal Cable, VOLT:DC 3.3V
PX0101A
Serial Cable
The Keysight PX0101A converts ferrule terminals to BNC terminal for trigger or interlock connection. It supports the Keysight M9601/02/03/14/15A.
-
Product
PXI Octal SPDT RF Switch 6GHz 50 SMA Terminated
40-880-004
RF Switch
A range of 50Ω SPDT RF switching with automatic termination of unused signals. Available as a dual switch in a 1 slot PXI module, a quad switch in a two slot PXI module or hex and octal switches in three slot PXI modules.
-
Product
Manual Fixture Kit with Changeable Cassette, Max number of probes (2N) 500 units, Max UUT 230 x 175 mm (wxd)
CMK-06
-
Linear click system with ball bearings, using gas springs.10 mm ESD-proof top cover with aluminum reinforcement bars.Steel base cabinet with detachable aluminum back and bottom panels.Detachable interchangeable case system with an 8 mm spring-loaded probe protection cover.Base cabinet fitted with a telescopic guide rail and catch.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 110 GHz, 50 Ω, SMA-1.0, External Termination, Latching
40-781A-921-LA
Relay
The 40-781A-921 (PXI) and 42-781A-921 (PXIe) modules consist of one microwave changeover switch capable of switching up to 110 GHz in 50 Ω. They are available with external terminations and connections are via front panel mounted high quality SMA 1.0 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
40-788-121-TE
Multiplexer Module
The 40-788-121-TE (PXI) and 42-788-121-TE (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
LXI Microwave Multiplexer, SP4T, 9-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-803-509
Multiplexer Module
Our 60-803-509 is a 9 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe RF Multiplexer, Single 6-Channel, Terminated, 8GHz, 50Ω, SMA
40-881B-001
Multiplexer Module
The 40-881B-001 (PXI) and 42-881B-001 (PXIe) are single 6 to 1 50Ω RF multiplexers with 8GHz bandwidth and automatic termination of unused signal channels. It is available as a single or dual MUX in one and two slots respectively.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 18GHz, 50Ω, SMA, Internal Termination
40-781A-021
Relay
The 40-781A-021 (PXI) and 42-781A-021 (PXIe) are single SPDT 18GHz microwave relay modules with internal terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50GHz in 50Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI/PXIe Microwave Transfer Switch, Single, 18 GHz, 50 Ω, SMA, Failsafe, Remote Mount
40-782B-521-E
Switch Module
The 40-782B-521-E (PXI) and 42-782B-521-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 18 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-021-TE
Multiplexer Module
The 40-788-021-TE (PXI) and 42-788-021-TE (PXIe) are single failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
All-In-One Unit
RH-8800
-
"RH-8800" is an All-In-One digital microscope, which enables intuitive and comfortable operation by integrating "Observation", "Recording", "Measuring", together as one.
-
Product
Water Alarm With Dual Remote Sensors
00802
-
Warns of leaks from two locations up to 12 feet apart and Sounds Alarm
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 18GHz, 50Ω, SMA, Remote Mount
40-785C-521-E
Multiplexer Module
The 40-785C-521-E (PXI) and 42-785C-521-E (PXIe) are single SP6T 18GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
Measuring system for GIS Remote Control Digital Recorder
VFT
-
The VFT-Measuring System TR-AS RC for VFT is special designed for high bandwitdth and allows measurements of very fast transients (VTF) in a frequency range from power frequency up to 100MHz directly with help of capacitive sensor, e.g PD-Sensors Installed in GAS-insulated Switchgear (GIS)
-
Product
Land Platform Inertial Navigation Unit
Epsilon™
-
Versatile, Epsilon™ family provides advanced applications, even in GNSS denied environment: navigation (position & heading), aiming aid, driving aid. It covers all tactical applications from logistic to infantry fighting vehicles, as well as main battle tank.- Can be integrated with small artillery caliber to provide precision pointing- Connectable to any Battle Management system- Immune to magnetic disturbances
-
Product
PXI/PXIe Microwave Relay, Triple SPDT, 50 GHz, 50 Ω, SMA-2.4, Remote Mount, Failsafe
42-780B-553-E
Relay
The 40-780B-553-E (PXI) and 42-780B-553-E (PXIe) are triple failsafe SPDT 50 GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
Product
LXI Microwave Multiplexer, SP6T, 13-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-513
Microwave Multiplexer
Our 60-800-513 is a 13 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Quad 8 To 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-763A-004
Multiplexer Module
The 40-763A-004 terminated quad 8 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-785C-423-E
Multiplexer Module
The 40-785C-423-E (PXI) and 42-785C-423-E (PXIe) are triple failsafe SP4T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Programmable Logic Unit PLUS
V2495
-
The V2495 can be controlled and programmed “on the fly” via the VME Bus or directly through the Mini-USB connector on the front panel. A Software tool is provided for free to easily upload the custom Firmware on the User FPGA.
-
Product
Measuring Complex for Registration of Test Parameters of a Pumping Unit
-
Portable portable complex for measuring and recording parameters of factory testing of horizontal pumping units.
-
Product
PXI Single 4 to 1 RF Multiplexer, 8GHz 50 Ohm SMA, Terminated
40-882A-001
Multiplexer Module
The 40-882A-001 is a single 50Ω 4 to 1 RF multiplexer with 8GHz bandwidth. The 40-882A range of multiplexers have automatic termination of unused signals and are available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules.
-
Product
Differential Pressure Units
1120 Series
-
Model 1120 Differential Pressure Unit is a proven and reliable sensing element used in all Meriam Bellows Gauges. It is available in ranges as low as 0-30 w.c. or as high as 0-500 PSI. The light weight and compact differential pressure unit incorporates a rupture-proof and leak-proof bellows plus other features that ensure ruggedness and reliability. This basic unit is suitable for activating indicators, recorders, transmitters, switches and controllers. It is also available as a separate assembly for that purpose.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 40 GHz, 50 Ω, SMA-2.9, Terminated, Failsafe
42-785C-542-T
Multiplexer Module
The 40-785C-542-T (PXI) and 42-785C-542-T (PXIe) are dual failsafe SP6T 40 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Failsafe
42-785C-571-E
Multiplexer Module
The 40-785C-571-E (PXI) and 42-785C-571-E (PXIe) are single failsafe SP6T 67 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Front Panels for Plug-In-Units | ATCA
-
EMC front panel for ATCA plug-in-units | 8 U x 6 HP | classic or ergonomic
-
Product
LXI Microwave Multiplexer, SP6T, 12-Bank, 26.5GHz, 50Ω, SMA, Terminated
60-800-312
Multiplexer Module
Our 60-800-312 is a 12 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.





























