Product
Resistivity Cell For N1413 (50 Mm Electrodes)
N1424A
Resistivity Cell
The N1424A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424A to the B2985B/87B.
-
Product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
Resistivity Cell
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
Product
E-Band Signal Analysis Reference Solution
Reference Module
The E-band signal analysis reference solution provides an effective measurement solution for today’s wideband signals as well as emerging communications standards. With the M1971E waveguide harmonic mixer, which provides a 55 to 90 GHz input; Keysight oscilloscopes, which provide excellent signal integrity; and the powerful 89600 VSA software, you have a high-quality wideband measurement solution. A simple user interface also provides integrated mixer setup, correction and LO optimization, allowing for accurate measurements.
-
Product
AC Reference Modules
Reference Module
NAI offers a variety of AC reference modules that provide a drive capability to 5 VA. The units are transformer-isolated and operate over a frequency range from 47 Hz to 10 kHz. These modules are specifically designed for rugged defense, commercial aerospace, and industrial applications.
-
Product
Solar Reference Cell
-
The Solar Reference Cells consist of a 20 mm x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 mm x 70 mm x 16 mm metal enclosure with a protective quartz window and a temperature sensor. Designed for calibrating the irradiance of solar simulators used for testing solar cells and modules.
-
Product
PV Reference Cells
-
Our silicon-based solar irradiance sensors (Si-Sensors) measure the irradiance intensity on your photovoltaic system with utmost precision.
-
Product
Photovoltaic
-
For solar panel installations, problems such as insulation resistance degradation or issues with ground/earth continuity can pose a risk to safety as well as efficient operation. Continuous and predictive maintenance is essential to ensure regulatory compliance as well as the prevention of electrical hazards and fire risks, and enables operators to ensure the optimal performance of PV installations.
-
Product
Calibrated Solar Reference Cell
-
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
Product
Photovoltaic and Electrical Installation Testers
-
Photovoltaic electrical installation safety testing is a special area of electrical installation safety testing as it also entails tests and measurements on DC systems, which are relatively uncommon in most domestic, commercial and to a certain extent industrial environments. There is also the addition of photovoltaic-specific tests that are outside the realm of standard test and measurement procedures.
-
Product
Reference Antennas
Type NRD
-
Reference antennas are precision dipole antennas that offer a fixed 2.15 dB of gain over an isotropic antenna along the major lobe axis at specified frequencies (2.15 dBi). They are intended to be used for antenna field pattern and gain measurements, or general RF sensing in the laboratory.
-
Product
Direct Burial Half Cell Reference Electrode
DB-A
-
Model DB-A Copper-Copper/Sulfate Reference Electrode designed for direct burial for long term monitoring of buried or earth contacting structures.
-
Product
Voltage References
-
Renesas' wide selection of voltage reference (Vref) circuits offer accurate and stable reference voltages unaffected by external influences such as variation in temperature, input voltage and time.
-
Product
Frequency Reference
E8-X
-
The Quartzlock E8-X is a breakthrough in exceptionally low cost, miniature, traceable, calibration-free, off-air frequency & time standards. These references maintain the high frequency & time accuracy required for demanding applications.
-
Product
NI Real-Time Test Cell Reference System
778820-35
test
DIAdem Advanced with DAC Bundle, Perpetual License, Include 1 Year SSP
-
Product
Voltage References
-
Analog Devices offers the widest selection of high performance voltage references in the industry. Our products range from high accuracy, low noise for high end industrial applications to general-purpose, low power for handheld, battery-powered applications. ADI is the ultimate source for design engineers looking for the perfect voltage reference that is cost effective, reliable, and dependable.
-
Product
Solar Photovoltaic
-
Scientific Computing International
Automated metrology system designed for rapid, reliable, and accurate characterization of nearly any unpatterned thin film.
-
Product
Low Concentration Photo-Voltaic (LCPV) & High Concentration Photo-Voltaic (HCPV) Cell Testing
-
Concentrated PV Cell testingPhoto-biological studies of plants, animals, and cell culturesSemiconductor testingPhoto-toxicity researchMaterial degradation researchAccelerated UV and solar exposure testing of color fastness and material stability for paints, textiles and plasticsAtmospheric photochemical pollution research
-
Product
Micropower Voltage Reference
ISL21010
-
The ISL21010 is a precision, low dropout micropower bandgap voltage reference in a space-saving SOT-23 package. It operates from a single 2.2V to 5.5V supply (minimum voltage is dependent on voltage option) and provides a ±0.2% accurate reference. The ISL21010 provides up to 25mA output current sourcing with low 150mV dropout voltage.
-
Product
Load Cells
-
is a transducer that is used to create an electrical signal whose magnitude is directly proportional to the force being measured.
-
Product
Reference Thermometers
-
Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
Product
nVision Reference Recorder
-
AMETEK Sensors, Test & Calibration
Accurate enough to replace a deadweight testerRugged enough to sit in 3 feet of waterPortable enough to complete calibrations anywhere
-
Product
HOT CELLS
-
Precisely engineered and constructed for continuous dependable protection and reliable everyday laboratory use. These cells come standard with shielding for the ionization chamber and utility connections.
-
Product
Shunt Voltage References
-
Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.
-
Product
Load Cell
-
Precise and robust and it has been designed to meet the requirements of a wide range of industrial weighing applications: hoppers, tanks, platforms. Is able to work in severe environmental conditions typical of applications in food, chemical and pharmaceutical industries.
-
Product
Reference Oscillator
REF Series 1.5” x 1.5” x 0.6”
-
*Connectorized Package *Free Running *Low Phase Noise *Output Power to +12 dBm Available
-
Product
Reference Voltage Measurement Cell
C-80
-
Cells C-80 and C-100 are used as reference devices for measuring voltage during calibration and adjustment of OLT-series testers.
-
Product
Shaper Of The Reference Frequency
MFC
-
The mezzanine module (mezzanine) of the MFC is designed to reproduce on six output lines high-precision frequency values obtained by dividing the frequency from the built-in reference frequency generator.
-
Product
Reference Temperature Calibrator
JOFRA™ RTC-187
-
AMETEK Sensors, Test & Calibration
RTC-187 provides high-quality temperature measurement from -45 to 180°C. The 180°C is a 25° expansion over the range of the RTC-157, and it’s now the hottest temperature available for a calibrator that also supplies cold temperatures.