Microphone Calibrators
an accurate sound units of measure to facilitate comparison to and adjustment of instruments.
See Also: Microphone Calibration
-
Product
1 Mm Calibration Kit
85059B
Mechanical Calibration Kit
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
Calibration Kit YAV90MMU
YAVMMUCK
Mechanical Calibration Kit
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
Mechanical Calibration Kit
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
Mechanical Calibration Kit
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Probes, Sensors, Measurement Microphones, Calibrators, Accessories
-
Passive Probes, Active Probes, USB Isolators, Noise & Vibration Sensors & Accessories, Electro-Acoustic Test Accessories
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
Electronic Calibration Module
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
Mechanical Calibration Kit
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Measurement Microphones
-
All microphones are omni-directional and 48V phantom powered. The XL2 Analyzer microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the XL2 automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
Mechanical Calibration Kit
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
Microphone Interfaces
MEMS
-
Listen offers 2 MEMS digital microphone measurement interfaces from Portland Tool & Die, the laboratory-grade DCC-1448 and the low cost PQC-3048 for production line use.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
Product
Microphone Preamplifier
426A05
-
Preamplifier for 1/4" side vented prepolarized microphones.
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Microphone Preamplifier
426E01
-
Nominal Microphone Diameter: 1/2 Gain -0.05 dBFrequency Response (0.1 dB) (re 1 kHz)6.3 to 125000 HzFrequency Response (-3 dB) (re1 kHz) Phase Linearity (<1 )32 to 20000 Electrical Noise (A-weight)<2.8 V<2.8 V[1] Output Slew Rate 2 V/S[2]
-
Product
Outdoor Microphones
-
Is a measurement microphone for all-weather conditions designed for use with sound level meters.
-
Product
ICP Microphone System
HT378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Measurement Microphone System
7052SYS
-
The 7052SYS Type 1.5TM measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 4 Hz to >20 kHz response, 20 mV/Pa sensitivity and a "A" weighted noise floor less than 20 dBA.
-
Product
Precision Condenser Microphone
377B02
-
1/2" free-field, prepolarized condenser microphone, typical sensitivity= 50 mV/Pa (+/-1.5 dB), 3.15 Hz to 20 kHz (+/-2 dB).
-
Product
50KHZ MEASUREMENT MICROPHONE
M50
-
The M50 is a precision engineered 50kHz omnidirectional measurement microphone ideally suited for acoustical measurements including high-end loudspeaker design and quality control, scientific research, measurements of ultrasonic or subsonic transducers, or any application where an extremely accurate free-field measurement microphone is required.
-
Product
Calibration
-
Testwave LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send recall notices before your equipment calibration expires, and if we don't hear from you, we will call, to make sure you stay in compliance for your calibration requirements.
-
Product
Calibration
-
Calibrations of electronic equipment is one of the activities that Kiwa Dare offers to its clients. these calibrations are under accreditation in the field of electrical quantities. Besides calibrations in the field of DC current, DC voltage and low frequency (test and measuring) equipment, Kiwa Dare is specialized in calibrating high frequency measuring equipment and in particular EMC equipment in a frequency range of (DC) 40 GHz. New the site validation calibrations whereby Kiwa Dare can calibrate shielded rooms (Faraday room) and anechoic chambers under accreditation.
-
Product
Calibrators
-
Fluke offers a wide range of pressure calibration tools with precision pressure measurement from 15psi/1 bar to 10,000 psi/690 bar boasting 0.025% full-scale accuracy. Everything from simple test gauges to calibrators with built in electric test pumps. Easy to use, rugged and reliable construction and an industry best 3-year warranty. Fluke means pressure.
-
Product
Microphone preamplifier
PRE-01
-
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
Product
Calibration
-
Calibration of a measuring tool is an operation that allows an assessment of the accuracy of the measurement, and the adjustment of the measuring tool so that it is more accurate. In scientific formulation, calibration makes it possible to evaluate the measurement error.
-
Product
Special microphones
-
G.R.A.S. Sound & Vibration A/S
Special microphones are often required for applications where there are particular requirements regarding the methods of measurements and configurations





























