ATE
ATE systems are used to test semiconductor devices, printed circuit boards, and electronic systems during manufacturing. AI prompted RL created', prevails upon the UUT to demonstrate It's fulfillment of test requirements.
See Also: Automatic Test Equipment, ATS, Functional ATE, Combinational ATE, Semiconductor Test, PXI Switching, PXI Chassis, PXI Matrix, Automated Test Equipment, Automated Test Systems
-
Product
LXI High Density 64x16 2A Matrix
60-554-002
Matrix Switch Module
A high-density single pole matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
Product
PXI 8 Slot BRIC Solid State 384x8 1-Pole (12 sub-cards)
40-563A-121-384X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance PXI matrix requirements and are constructed using solid-state switches. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 2 Amp MUX, Single 16-Channel 2-Pole
40-635-102
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Coax Switches
-
With up to DC - 53GHz bandwidth, low insertion loss, high isolation, and high repeatability, these switches are used to support SATCOM, aviation, military and commercial telecommunications, medical imaging, and ATE systems.
-
Product
PXI/PXIe RF Multiplexer, Quad 4-Channel, Terminated, 8GHz, 50Ω, SMA
42-882B-004
Multiplexer Module
This multiplexer has low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40/42-882B MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
Product
PXI Multiplexer Single 48 Ch 1 Pole
40-632-021-48/1
Multiplexer Module
This series of general purpose multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 68-pin connector. Available reed relay formats are 1-pole, 2-pole and 1-pole screened.
-
Product
PXI MUX 4 Bank, 16 Channel Screened 1 Pole
40-610-021-S-4/16/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI/PXIe Very High Density Multiplexer, 198-Channel, 1-Pole
40-675B-002-198/1
Multiplexer Module
The 40-675B-002-198/1 (PXI) and the 42-675B-002-198/1 (PXIe) are 198-channel, 1-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
DC-18GHz Coaxial Multiplexer
MS2102A
-
Universal Switching Corporation
Enhancing ATE systems and satellite monitoring, the System MS2102A is a compact high-performance modular switch multiplexer specifically designed for routing any coaxial signal within the DC-18GHz bandpass. Configurations are available from 1x10 to 1x100 (or dual 1x50), and custom configurations are a simple to accomplish. The 100 ports are normally open (reflective) when not routed. For a self-terminating version of this unit, please see Model MS2103A.
-
Product
PXI 8 Slot BRIC 330x8 1-Pole (11 sub-cards)
40-561A-121-330X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 8 Slot BRIC 270x8 1-Pole (9 sub-cards)
40-561A-121-270X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI-2522, 53-Channel, 2 A, SPDT PXI Relay Module
778572-22
Relay
53-Channel, 2 A, SPDT PXI Relay Module - The PXI‑2522 is a general-purpose switch module that features independent single‑pole double‑throw (SPDT) Form C armature relays. Each relay is nonlatching with very low on-resistance and low thermal offsets. The PXI‑2522 is fully software programmable, and it supports onboard relay count tracking. With an efficient coupling of voltage/current capability and relay density, this switch module is ideal for automated test equipment (ATE) loads or for controlling heaters, lights, and fans.
-
Product
DC Power Module, 20V, 5A, 100W
N6743B
Power Module
The Keysight N6743B is a 100 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.
-
Product
Cable Test Instruments
-
Do you have systems that include a large number of coaxial devices? Our best-selling ATE product line includes a cable test instrument that automates the task of precision testing of coaxial devices. These series of cable test instruments include both a scalar and a vector model. They offer fast precision measurements in a rugged and small portable package. Programming options allow instant test set-up and measurement recall from a potential database of thousands of test devices. Using a user interface that includes clear instructions with picture prompts, anyone can successfully make precision microwave measurements with a simple click of a button.
-
Product
Single 24x6 1-Pole High-Density PXI Matrix Module
40-520-302
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
DC Power Module, 150V, 2A, 300W
N6777A
Power Module
The Keysight N6777A is a 300 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.
-
Product
PXI Single 64x4 Matrix 2-Pole Switching
40-533A-022
Matrix Switch Module
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
Product
PCI High Density Screened MUX 49 Ch 2 Pole
50-670-021-S-49/2
Multiplexer Module
The 50-670 series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.The 50-670 shares exactly the same architecture as the established PXI 40-670 module.
-
Product
EMX-75XX
Digital I/O
The EMX-75XX Series adds to AMETEK VTI Instruments' growing PXI Express (PXIe) Core Automated Test Equipment (ATE)TM family as a high-current, high-density digital input/output line of modules. Unlike many static I/O PXIe modules on the market today, the EMX-75XX Series can sink or source up to 300 mA on each channel. Delivering beyond just 2 V and 5 V, engineers can program the cards to support a wide range of voltages and more—on every channel, for both input and output.
-
Product
2-CH MIL-STD-1553A/B Bus Simulator Module
1553 WA73A-455
-
The WA73A-455 MIL-STD-1553A/B Bus Simulator Module allows a system controller in an ATE system to communicate with and test devices that conform to the MIL-STD1553A/B data bus used in military aircraft and communications systems. Each of the WA73A-455's two channels operate as two separate and independent channels with their own VXIbus logical address, interrupts, and complete set of controls and indicators. As a result, each channel of the WA73A-455 is truly an independent instrument, and, therefore, individually programmable.
-
Product
PXI Very High Density Multiplexer, 5-Channel, 32-pole
40-670C-022-5/32
Multiplexer Module
The 40-670C-022-5/32 is a 5-channel, 32-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
LXI High Density 128x4, 2A Matrix - 60-551-022
60-551-022
Matrix Switch Module
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
Product
Rack Mount MW Signal Generators
-
The Rack Mount platform of the Lucid signal generator is designed to offer maximum channel density at minimum cost of space. Offering up to 4 phase coherent channels in a 19” 1U box, the rack mount platform is by far the best in its class for signal density. Featuring fast switching speed, superior signal integrity and purity, removable memory card for maximum security, all the necessary modulated signals for analog communication systems, built in LAN and USB interfaces, this platform meets today’s most demanding specifications, needed for ATE and production lines.
-
Product
Automated Aerospace and Defense Test
test
Obsolescence management, evolving RF requirements, and design for test (DFT) challenges every test organization in the aerospace and defense industry. Organizations are transitioning from rack-and-stack box instruments and closed-architecture automated test equipment (ATE) systems to smarter test systems built on a modular platform that scales to meet current and future needs.
-
Product
Advanced Power System - DC Power Supply, 40 V, 25 A, 1000 W
N6952A
DC Power Supply
When designing high performance ATE systems, there's an art to the tradeoffs you make when asked to "integrate fast and test faster within budget." That's why Keysight's N6900 Series DC power supplies are small, flexible and market-leading fast. And with our VersaPower architecture, you can tune the N6900 for the optimum balance of test coverage, quality and time.
-
Product
PXI 2A Multiplexer, 1-Bank, 128-Channel 1-Pole
40-614-015
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI 4 Slot BRIC 220x4 2-pole (5 sub-cards)
40-562A-022-220X4
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 8 Slot BRIC 110x16 1-Pole (10 sub-cards)
40-562A-121-110X16
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 2A Multiplexer, 2-Bank, 64-Channel 1-Pole
40-614-010
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.



























