Product
Circuit Breaker Analyzers & Timers
-
CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.
-
Product
Coupler And Decoupler Used With Lightning Impulse Simulation Tester
-
All electric equipments & systems is required Impulse Simulation Test to the to be tested under the condition where the power source is applied to the product-under-test.At this test condition, the decoupler is needed to reduce the impulse flowing through the power line while testing. And the coupler which is inserted between tester and product, to simulate the actual condition, so the electric circuit of decoupler is prescribet by IEC rules.
-
Product
PoE Power Sourcing Equipment For TBOX300/tBOX400/tBOX500 Series
PSU120-259
-
*M12 5P DC input*Terminal block PoE power output, maximum 120W*Designed for tBOX300/tBOX400/tBOX500 series*CE, FCC, EN 50155 and IEC 60945 compliant
-
Product
Oil Tan Delta Tester
OTD
-
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. The microprocessor controlled inductive heater means that there is uniformity of temperature throughout the cell, in compliance with IEC 60247, and for cooling a fan effectively speeds up the cell cooling time. The instrument has a temperature measuring range of 10 to 110 C, with an accuracy of 1 C. It can be set to preheat before testing takes place. The automated oil drain facility negates the need to move the oil vessel. User safety is paramount and with this in mind, Megger have designed independent and dual redundant high voltage cut-off circuitry. If for any reason the user needs to abort the test, this can be done so by pressing any key, immediately terminating the test and removing the high voltage. The design of the cell components maximise oil fill rate but minimise turbulence in oil flow and eliminate trapping of air. With only 32 cell components, it is easy to assemble and disassemble.
-
Product
Magic-Kit 11 - the cost-effective IEC solution
Magic-Kit-11
-
Shielded subracks for IEC applications. EMC subrack made of sheet steel for extremely fast mounting and EMC without seals.
-
Product
NI-9351, 4-Channel C Series Functional Safety Module
784446-01
Functional Safety Module
4-Channel C Series Functional Safety Module - The NI-9351 works with 24 V industrial logic levels to directly connect to various sensor types, including light curtains, emergency e-stop buttons, and final elements such as relays, contactors, and motor drives. The NI-9351 is an analog input and digital I/O Functional Safety Module capable of SIL 3 certification according to IEC 61508. You can use the Functional Safety Editor to program the safety logic solver, which resides in the module. The module features diagnostics for monitoring the status of hardware and the integrity of the connections.
-
Product
4G Router
ICR-2834GA01-S1
Router
ICR-2800-S1, EMEA, 2× Ethernet, 2× RS232/RS485, USB, GPS, Metal, EU ACC LTE Cat.4 with 3G/2G fallback. Security based on IEC 62443-4-2 level 1 GNSS receiver 1.3 GB eMMC storage to host customer SW applications 2× SIM with cover, eSIM ready.
-
Product
Sound Level Meters
-
Acoustic Data These definitions are intended simply as an aid to understanding and for this reason, some are not strictly scientifically accurate. For correct formal definitions, consult IEC standards 60651, 60804, 60942, 61252 and IEC 61672: 2003 part 1.
-
Product
HMM+™ Tester
Model 4702
-
The Model 4702 HMM+™ is a completely new tester primarily intended for device level testing and produces a current waveform as specified in the IEC-61000-4-2, from a 50 ohm source impedance system.*This tester provides device level test data that allows users to evaluate the IEC current waveform protection level of their devices. We included failure identification by leakage current increases in the 4702 tester so precise pass/failure levels can be closely measured.*The 4702 HMM+™ provides a new and improved test connection method for making quantifiable and repeatable device level HMM measurements.*Convenient, precise, repeatable operation*Computer controlled for automated testing
-
Product
Transformer Test Equipment
-
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
Product
1U Type Power Supply; ATX 270 W
PS270-1U
-
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 18A (0.5A min)**+3.3V, 16A (0.5A min)**+12V1, 16A (1A min)**+12V2, 10A (1A min)**-12V, 0.8A**+5Vsb, 2.5A*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CSA 22.2 NO.60950-1, IEC, UL, NEMKO, CE*Dimensions: 150 x 81.5 x 40.5 mm*Compatible with Axiomtek products: AX61120 / AX60530
-
Product
Wall-Mount Miniaturized Oxygen Analyser
Rapidox 2100-OEM-RSB-WALL
-
The Rapidox 2100 OEM-RSB-WALL is a wall mount version of our miniaturised 24V OEM oxygen (O2) analyser. The compact (4.5″ x 3.0″) circuit is integrated into a neat IP65 wall mount polycarbonate box, with a clear smoked hinged lid. Behind this is a clear OLED display and menu keypad. The box is completely electrically isolated and meets all UL and IEC standards for these types of enclosures.
-
Product
IEC61032 Test Probe Pin
CX-112
-
Shenzhen Chuangxin Instruments Co., Ltd.
1. Jointed test finger probe (Figure 2 / Test Probe B / IEC 61032)This is a precision probe made in accordance with all IEC standards. Examples are IEC 61032, 60950, 61010 and 60601; and it is also used for Canadian and USA standards. It features a palm simulator and a restricted joint movement, which simulates the characteristics of the human hand. The finger is made of stainless steel and the rest of the instrument is Delrin®. Handle is designed to accept either a banana jack or a force gauge.It is no longer necessary to have a separate probe for the medical safety standard. This one probe will meet all the different requirements that are in the IEC standards.
-
Product
8GE+4SFP+4G Combo Port Managed Redundant Industrial Switch
EKI-7716G-4F4CI
Ethernet Switch Module
Certified to IEC 62443-4-2 SL2, 12 ~ 48 VDC power input and 1 relay output, -40 ~ 75°C wide-range operating temperature (EKI-7716G-4F4CI). EN50121-4 approval for railway trackside deployment, NEMA TS2 for traffic control, Management: SNMP v1/v2c/v3, WEB, Telnet, Standard MIB, Private MIB.
-
Product
K Thermocouple Air Probe
TP744
-
Thermocouple Type “K” air probe. Tolerance according to IEC 60584-2 standard.
-
Product
K Thermocouple Immersion Probe
TP742
-
Immersion “K” Type thermocouple probe. Tolerance according to IEC 60584-2 standard.
-
Product
High Voltage
-
Accurate measurement of high voltages acc. to VDE 0432 und IEC 60060 in conjunction with a high voltage divider.For the measurement, the principle of capacitive or resistive divider is used, which can be selected in the peak voltage meter.
-
Product
IEC 61850-3 L3 Modular Managed Switch
EKI-8528-4XF
Ethernet Switch Module
3 x 8 Gigabit ports module slots + 4 x 10G SFP+ portsDual power input options for 110/220V AC or 24-48V DC power moduleL3 functions: RIP v1/v2, OSPF, VRRP, PIM and NATFully layer 2 and TSN-enabled functionsFeatures IEEE 802.1AS Time Synchronization, IEEE 802.1Qbu Frame Preemption, IEEE 802.1Qbv Time Aware Shaper and IEEE 802.1CB Seamless RedundancyRedundancy: X-Ring Pro (< 20ms @250units), X-ChainManagement: SNMP v1/v2c/v3, WEB, Telnet, standard MIB-40 ~ 75˚C wide-range operating temperature
-
Product
Loss Tangent M in Dielectric Oil
TAND220A
-
The measuring instrument type TAND220A complies with the international standard IEC 61620. The instrument is based on the so-called "low-amplitude, low-frequency alternating current square wave method" and allows accurate measurements of conductivity and relative permittivity. Conductivity measurement in the range of 0.01 pS/m to 20,000 pS/m allows the use of this instrument for quality control of high resistivity liquids even at room temperature. The TAND220A works with a low test voltage and also with a low test current so that it does not represent a danger for the operators.
-
Product
Qualification and Quality Control Tests
Techsquare
-
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.
-
Product
Fluorescent Lamp Asymmetric Pulse Tester
UI2002C
-
UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp voltage, lamp current , average and total power of lamp. • Lamp voltage range: 10~300V • Lamp current range: 10mA~1.0A • Lamp power range: 0.5~300W • Tolerance is 5%
-
Product
LST-2000 Laser Safety Test System
-
Hangzhou Everfine Photo-E-Info Co., LTD
The system can measure the spectral power distribution, radiant power, radiant energy, apparent light source size, pulse energy and other parameters of the laser light source, and classify the laser light source according to the standard IEC 60825.1. Because laser measurement involves more condition parameters, limit calculation and judgment process is complex, so this system adopts systematic design, the measurement complexity is simplified, the hardware adopts componentization module, users only need to follow the software prompts, carry out the corresponding steps of operation can accurately measure the effective radiation value under the corresponding conditions. The software calculates the relevant reachable emission limits and automatically classifies the laser product's safety level.
-
Product
Reach-In Solar Panel Test Chamber
-
For testing various size solar panels WIEBER designs and manufactures Solar Panel Test Chamber. The test are to be performed according to various standards of ASTM, IEC, UC etc. Solar panels need to pass environmental tests as per IEC and other standards requirements to prove their long term performance and resistance to temperature and humidity extremes. Solor Chamber also known as Solar Photovoltaic Testing Chamber and PV Module Test Chamber.
-
Product
Mineral Insulated Thermocouples IEC
-
Durable Mineral Insulated type thermocouples to suit a wide range of temperature measurement. Various probe types, lengths and diameters available.
-
Product
IEC60950 50mm Impact Test Balls
CX-15
-
Shenzhen Chuangxin Instruments Co., Ltd.
The Impact Test Ball is a specially machined ball to test impact resistance according to IEC, CSA and UL Standards. It is made of chrome-plated-steel for durability, and is fitted with an eyelet to facilitate testing for pendulum applications. Eyelet is threaded to the ball to allow attachment of a handle or force gauge. Weights are closely controlled.
-
Product
Pre-Scan Emissions/Immunity Chambers
-
3m pre-scan Immunity/Emissions semi-anechoic chambers are designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 compliant radiated immunity and emissions measurements. When using this chamber for ANSI C63.4 pre-compliant radiated emissions pre-scan measurements there’s a limited scan height.
-
Product
Cylindrical Inductive Proximity Sensor
-
Shanghai Pubang Sensor Co.,Ltd.
1.Non-contact position detecting,non-wear,high-reliability2.Clear visible indictor design,easy to estimate the working state3.Various type of Sensor,diameter spec.from Φ4 to Φ34,housing length,from ultra-short,short to standard type4.Equipped cable and connector,easy to maintain5.Protection class IP67(IEC)
-
Product
2-Port SFP Ethernet Card
ECU-P1524PE
-
2-port SFP Ethernet cards supporting HSR/PRP (IEC 62439-3) are specialized NICs designed for zero-delay, high-availability industrial networks. These cards feature dual SFP ports to operate as Dual Attached Nodes (DAN) in HSR ring topologies or parallel PRP networks.
-
Product
Digital Network Analyzer
F6880
-
The Doble F6880 Digital Network Analyzer (DNA) reveals details that are essential to helping protection engineers and relay test technicians quickly resolve issues in IEC 61850 network traffic.
-
Product
HCAI-1 High Current Arc Ignition Tester
HCAI-1
-
The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011
and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety.