DoS
1) To take a service offline. 2) Disk Operating System.
-
Product
Galvanic DO Electrode for DO and BOD Measurements in Laboratories
9521-10D
-
- Ideal for laboratory use- Integrated with built-in temperature sensor- Comes with replaceable 7544 DO Electrode Tip, detachable BOD bottle adapter and stirrer - Use magnetic stir plate during measurement- Waterproof
-
Product
High-Density 128-CH Isolated DIO/DI/DO PCI Cards
PCI-7442/7443/7444
-
Responding to the industry"s need for high-density digital input/output modules, the ADLINK PCI-7442/7443/7444 DIO card series delivers up to 128 opto-isolated channels for a wide range of demanding PCI-based applications. The PCI-7442/7443/7444 series comes with 64 (PCI-7442) or 128 (PCI-7443) opto-isolated digital inputs and 64 (PCI-7442) or 128 (PCI-7444) opto-isolated digital outputs. With a 1250 VRMS (excluding cables) channel-to-system isolation protection, these cards are shielded from damage caused by accidental contact with external voltage while promoting simple ground connections. All input channels are identical non-polarity with each line isolated and suited to collect digital inputs even at high-noise environments. Featuring a Change-of-State (COS) interrupt function, the PCI-7442/PCI-7443 instantly generates an interrupt request to the PCI controller when it detects a sharp change in the logical state of any of its digital inputs.
-
Product
Galvanic DO Sensor
Model 20
-
The Model 20 Galvanic DO Sensor utilizes proven galvanic sensing technology – without a question the most accurate and reliable DO sensing technology ever developed. The pure platinum cathode makes the sensor incapable of being poisoned by other gases often found in impure waters, such as hydrogen sulfide. This sensor utilizes the only DO sensing technology that is successful in continuous de-nitrification monitoring and control applications. It is also the only sensor design that can be used continuously in very violent pure liquid oxygen injection systems. Complete systems are supplied with over 5 years of sensor electrolyte and membranes.
-
Product
Galvanic DO Analyzer
Model 2100
-
The Reliant Model 2100 Dissolved Oxygen (DO) Monitoring and Control System is a rugged, full featured dissolved oxygen analyzer which utilizes a long life, low maintenance galvanic DO sensor.
-
Product
32-Ch Isolated DI And 32-Ch Isolated DO USB 3.0 I/O Module
USB-5856
-
USB 3.0 SuperSpeedDaisy chainable by built in USB hub32-ch digital input and 32-ch digital output with 2,500 VDC isolationWide input voltage range (10 ~ 30 VDC)Wide output voltage range (5 ~ 40 VDC) and high output current (350 mA/ch)Quick removable European type connectorLED indicators for I/O statusSupported operating systems: Windows 10/11
-
Product
Low-Profile 16-CH Isolated DI & 16-CH Isolated DO PCI Card
LPCI-7230
-
ADLINK LPCI-7230 is 32-CH isolated input and/or card. It provides a 2,500 C optical isolation protection. Two wide input range of the LPCI-7230 makes it easy to sense the status of external devices. The non-polarity characteristic is suitable for a wide variety of industry applications. The LPCI-7230 devices also feature a wide output range from 5 to 35 V, which is suitable for relay driving and industrial automations applications. The LPCI-7230 also provides two interrupt sources on digital input channels, which are easily user configurable.
-
Product
Dissolved Oxygen (DO) & Temperature Pen
Ultrapen™ PT5
-
*Reliable Repeatable Results*Accurate*Affordable*Easy to Use*Rugged Design*Ensure Product Quality*Reduce Waste*Protect the Environment
-
Product
32-CH DI & 32-CH DO 12 MB/s High-Speed Card
PCIe-7200
-
- x1 lane PCI Express interface- 32-CH TTL digital inputs and 32-CH TTL digital outputs- Up to 12 MB/s transfer rate- Onboard programmable timer pacer clock- Support handshaking digital I/O transfer mode- Bus-mastering DMA for both digital inputs and outputs- 5 V power available on connectors- Compact, half-size PCB
-
Product
Portable optical DO meter
ARO-PR
-
The Portable optical DO meter makes use of the fast-response optical DO sensor RINKO, maintaining its high-speed response performance (99% response < 7sec). The meter probe is equipped with a temperature sensor close to the sensing foil, and the measurements are made by simply inserting the probe into a DO sample bottle (the calibration is carried out using the National Metrology Institute of Japan (NMIJ) certified traceable gases standards). Differently from galvanic electrode sensors, the instrument does not require water sample stirring or fixing reagents, since there is no oxygen consumption. Thus, the required time to estimate dissolved oxygen is considerably reduced. The display unit shows the output instantaneously, and you can check the measured values in real time.
-
Product
PXI-6239, 8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module
779626-01
-
8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6239 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6239 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6239 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
Logger version optical fast DO sensor
RINKO I / I D
-
Rinko I is an autonomously deployable data logger with a fast response optical DO sensor. The instrument and the software with various operating mode offer flexible observations in the field. The small-sized and the self-contained unit with batteries and a data logger can be easily integrated on platforms (e.g. CTDs). Rinko ID has a depth sensor, allowing for DO vertical distribution measurements.
-
Product
PXI-6236, 4 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module
779622-01
-
4 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6236 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6236 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6236 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
PXI-6233, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module
779620-01
-
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6233 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6233 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
16-Ch Isolated DI, 16-Ch Isolated DO IDAQ Module
iDAQ-731
-
Hot-swappable in iDAQ systemEuro-type spring terminal blocks32-ch isolated DI/O (16-ch digital input, 16-ch digital output)High output driving capacityInterrupt handling capabilityDigital output type changeable between sink (NPN) type and source (NPN) typeIsolation protection of 600 VRMSSupport buffered acquisition/update rate up to 10kHz
-
Product
Logger version CTD profiler with optical fast DO sensor
RINKO-Profiler
-
CTD profiler with optical fast DO sensor
-
Product
PXI-6238, 8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Hybrid, Multifunction I/O
779624-01
-
8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6238 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6238 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6238 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
PXI-6232, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module
779618-01
-
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6232 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6232 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6232 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
Bluetooth® Enabled Dissolved Oxygen (DO) & Temperature Pen
UltrapenX2™ PTBT5
-
*Industry Leading Accuracy*Display DO in Concentration, % Saturation, or Both*Adjustable for Altitude and Salinity*3 Calibration Methods: Air, Water and 0 ppm DO*Dynamic Membrane Temperature Correction*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated ElectronicsWaterproofPowered by One N Type Battery (Included)
-
Product
Digital output version optical fast DO sensor
RINKO II / II D
-
Rinko II is a digital output version with a fast-response optical DO sensor. The instrument can be easily integrated on platforms, because it works with communications by RS-232C or RS-485 and an external power (12 to 24V DC).Rinko IID has not only a temperature sensor but also a depth sensor. Their models can monitor DO in real time, if you have a personal computer and an external power.
-
Product
Industrial Communication Gateway With TI Cortex A8, 2 LAN, 2 COM, 4 DI & 4 DO
ECU-1251D
-
TI Cortex A8 600MHz CPU with DDR3L 256MB RAMOnboard IO - 4DI / 4DOSupport web service for remotely on-line monitoringFirmware update by SD card and online updateData logger on SD cardSupport dual SIM slots for communication redundantSupport MQTT Client for cloud communicationWide Operating temperature: -40 ~ 70°C
-
Product
PCI-6154, 4 AI (16-Bit, 250 kS/s/ch), 4 AO, 6 DI, 4 DO, PCI Multifunction I/O Device
779340-01
-
4 AI (16-Bit, 250 kS/s/ch), 4 AO, 6 DI, 4 DO, PCI Multifunction I/O Device - The PCI‑6154 is a simultaneous-sampling, channel-to-channel isolated DAQ device. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. You can combine the channel‑to‑channel isolated analog outputs to generate signals greater than ±10 V (up to ±40 V by combining all four channels). The PCI‑6154 is ideal for a variety of applications including automotive test, industrial monitoring and control, and high-speed continuous data logging. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
PXI-6230, 8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Hybrid, Multifunction I/O
779616-01
-
8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6230 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6230 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6230 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
32-CH Isolated DI & 32-CH Isolated DO PCIe Card with High Input Range
PCIe-7432
-
ADLINK PCIe-7432 is a 32CH Isolated DI & 32CH Isolated DO PCIe Card, featuring robust 2,500V isolation protection, suitable for most industrial applications. Input range up to 24V makes it easy to acquire status of external devices (PCIe-7432HIR output range is from 5 to 35V), making it suitable for relay driving and industrial automation applications. Also provided are two easily configurable interrupt sources on digital input channels.





















