Product
Time-Resolved Electrochemical Quartz Crystal Microbalance
400C Series
-
The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).
-
Product
Sealed Electrochemical Cell [10ml-500ml]
FPS-2
-
FPS-2 Sealed Electrochemical Cell [10ml-500ml] is an electrochemical cell for laboratory research, designed for three-electrode testing, sealed or unsealed experiments, photocatalysis, corrosion studies, optical observation, or customized electrochemical workflows depending on the selected model.
-
Product
Spectroelectrochemical Cell
SEC-C
-
Spectroelectrochemistry (SEC) is aimed at the investigation of electrochemical reaction mechanism and the interface structure between electrolyte solution and electrode. Remarkable progress in this field and related technology enables SEC to be applied in wide areas.
-
Product
Potentiostat Galvanostat
PARSTAT 4000A
-
The PARSTAT 4000A stands alone in its ability to deliver high compliance voltage and wide dynamic current range, as standard, to cover a range of applications. The PARSTAT 4000A builds on PAR's history as the world-leader in DC electrochemical measurements and takes advantage of a common R/D team with Solartron Analytical, the world-leader in Frequency Response Analyzer (FRA) technology, to provide a best-in-class complete system.
-
Product
Electrical Resistance (ER) Monitoring
-
The electrical resistance (ER) technique is an "on-line" method of monitoring the rate of corrosion and the extent of total metal loss for any metallic equipment or structure. The ER technique measures the effects of both the electrochemical and the mechanical components of corrosion such as erosion or cavitation. It is the only on-line, instrumented technique applicable to virtually all types of corrosive environments.
-
Product
Gas Analysis
HPR-40 DEMS
-
The Hiden HPR-40 DEMS is a bench top or mobile cart mounted module for analysis of dissolved species in electrochemistry. The system is modular and adaptable. The system includes two differential electrochemical mass spectrometry ‘DEMS’ cell inlets, designed for material/ catalysis studies, cell type A, and electrochemical reaction studies, cell type B.
-
Product
Solid-State Battery Mold With Conductive Film
SBM1
-
An XRD test mold designed for solid-state battery research, X-ray diffraction analysis, and electrochemical material evaluation with customizable dimensions and reliable laboratory performance.
-
Product
Battery Rapid-Tester
Spectro CA-12
-
Non-invasive battery tester Spectro™ reads capacity with multi-model electrochemical impedance spectroscopy (EIS). A 'pass' gives a grace period; 'fail' requests replacement even though cranking may still be strong.
-
Product
Thin-Layer Optical Spectroelectrochemical Cell
TLO-1
-
Potentiolab Thin-Layer Quartz Glass Spectroelectrochemical Cell – Micro-volume (~200 µL) optically transparent cell for in-situ UV–Vis spectroelectrochemical measurements. Ideal for fast electrochemical kinetics, redox mechanism studies, and high-sensitivity optical monitoring. Available in multiple configurations for flexible experimental workflows.
-
Product
Screen-Printed Carbon Electrode With Ag/AgCl Reference (RE)
SPE01
-
A screen-printed silver (Ag) reference electrode designed for electrochemical sensing, biosensor development, environmental monitoring, and laboratory research with excellent reproducibility and customizable electrode configurations.
-
Product
Electrolysis Cell With Electrode Holder
-
CEC-1 Electrolysis Cell with Electrode Holder is an electrochemical cell for laboratory research, designed for three-electrode testing, sealed or unsealed experiments, photocatalysis, corrosion studies, optical observation or customized electrochemical workflows depending on the model.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
Product
3 Mm Glassy Carbon Disk Electrode
CGC1
-
3 mm glassy carbon disk electrode designed for electrochemical research, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), corrosion studies, electrocatalysis, and sensor development. Manufactured from high-purity glassy carbon with excellent chemical stability, a wide potential window, and low background current. Compatible with CHI104 systems and customizable for laboratory and OEM applications.
-
Product
Platinum Sheet / Platinum Anode-Cathode Electrode
PSP1
-
PSP1 Platinum Sheet / Platinum Anode-Cathode Electrode is a research-grade electrochemical electrode for use as a working electrode, counter electrode or custom laboratory assembly. It is suitable for voltammetry, electrocatalysis, corrosion testing, sensor research and electrochemical cell development.
-
Product
5μm Transparent Quartz Interdigitated Electrode Chip
TIF1
-
5μm transparent quartz IDE chip designed for MEMS, biosensing, gas sensing, electrochemical, and photoelectric applications.
-
Product
Reference Electrodes
-
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
Product
Cell Accessories For Five-Neck Electrolysis Cells
FF-1
-
Accessories for five-neck electrolysis cells, including gas inlet and outlet tubes, salt bridges, PTFE stoppers, liquid seals, and aeration components. Suitable for electrochemical research, electrolysis experiments, and laboratory cell assembly.
-
Product
Stainless Steel Electrode Clip (316 SS)
EC-1
-
EC-1 Stainless Steel Electrode Clip (316 SS) is an electrode holder, clip or electrochemical cell accessory designed to position electrodes securely and provide stable electrical connection during laboratory electrochemical testing.
-
Product
PPM Oxygen Sensors
-
At Process Sensing Technologies (PST), we specialize in offering replacement electrochemical oxygen sensors for a wide range of fixed and portable oxygen analyzers used in demanding industrial environments. Our Galvanic Electrochemical Sensors are meticulously designed to ensure accuracy and reliability, setting the standard for excellence in process sensing technology.
-
Product
Sealed Electrochemical Cell | Quartz & Glass Construction
SSQ-1
-
Super-Sealed Electrochemical Cell — A gas-tight electrochemical cell designed for CO₂RR, HER/OER, corrosion studies, electrosynthesis, and long-duration electrochemical experiments.
-
Product
PARSTAT MC Multichannel Potentiostat
-
The PARSTAT® MC (PMC) is the most modular and robust multi-channel electrochemical testing platform on the market.The PMC chassis provides a robust environment up to 10 modules, up to 20 channels.
-
Product
Sealed Jacketed Electrochemical Cell – Temperature-Controlled
DL-2
-
DL-2 Sealed Jacketed Electrochemical Cell – Temperature-Controlled is an electrochemical cell for laboratory research, designed for three-electrode testing, sealed or unsealed experiments, photocatalysis, corrosion studies, optical observation, or customized electrochemical workflows depending on the selected model.
-
Product
Carbon Monoxide Detector, CO
ENVIROMUX-CMD
-
Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes; 150 ppm after 10 to 50 minutes; and 400 ppm after 4 to 15 minutes. Flush or surface mount. Test functionality of electrochemical CO sensing cell. Connect to RJ45 or digital input sensor ports. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1000 ft (305m). LED indicators for operation status and system test. Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL.
-
Product
Oxygen Sensors, Analyzers and Accessories for Diving Products
-
PST are proud to be the preferred supplier of diving sensors to some of the most reputable rebreather manufacturers throughout the world.Here you will find replacement electrochemical oxygen sensors for all major brands and models of diving instrumentation devices.
-
Product
Constant Temperature Humidity Battery Test Chamber
-
Guangdong Test EQ Equipment co., Ltd.
- Battery-Specific Thermal Management: Dual-compressor cascade cooling (-40°C stability) and ceramic heaters for rapid high-temperature recovery.- Precision Electrochemical Control: Integrated battery cyclers with CAN/Modbus protocols, supporting SOP (State of Power), SOH (State of Health), and DCR (Direct Current Resistance) monitoring.- Safety-Centric Design-meet Hazard Level: Chambers are designed with Fire-resistant stainless steel interior, fire suppression,nitrogen purge system, and emergency power cutoff for thermal runaway prevention .- Data Acquisition & AI Analytics: Real-time logging of voltage, current, temperature, and pressure via LabVIEW/Python APIs. AI-driven anomaly detection reduces test cycles by 30%.- Energy Efficiency and Energy Storage: Heat recovery during discharge cycles cuts energy use by 25% (ISO 50001 compliant).
-
Product
Trace Hydrogen Analyzer
GNL-400
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-400 trace hydrogen analyzer adopts imported high-performance electrochemical sensor with latest micro computer technology. It has such functions of LCD display, upper & lower alarm, signal output and relay contactor alarm output. And can be used to measure the hydrogen concentration in nitrogen, oxygen and argon.
-
Product
20μm Transparent Quartz Interdigitated Electrode (IDE)
TIE1
-
20 μm transparent interdigitated electrode (IDE) fabricated on a high-quality quartz substrate for MEMS sensors, gas sensing, biosensing, optoelectronic detection, and electrochemical research. Manufactured using precision microfabrication with customizable electrode materials, dimensions, and layouts for laboratory, sensor development, and OEM applications.
-
Product
3μm Silicon Interdigitated Electrode (IDE)
SIE1
-
3 μm silicon-based interdigitated electrode (IDE) designed for MEMS sensors, gas sensing, biosensing, photoelectric detection, and electrochemical research. Fabricated using precision microfabrication on a silicon substrate, with customizable electrode materials, dimensions, and layouts for laboratory and OEM applications.
-
Product
50μm Large-Size PI Interdigitated Electrode (IDE)
FPB1
-
50 μm large-size flexible polyimide (PI) interdigitated electrode (IDE) designed for humidity sensing, gas sensing, biosensing, and electrochemical research. Manufactured on a durable PI substrate with customizable electrode materials, dimensions, and layouts for laboratory, sensor development, and OEM applications.
-
Product
Ceramic Constant-Pressure Solid-State Battery Test Cell
-
SSL1 Ceramic Constant-Pressure Solid-State Battery Test Cell is designed for solid-state battery, liquid battery or in-situ electrochemical research where stable assembly pressure, reliable sealing and repeatable cell geometry are important. It supports laboratory-scale testing, method development and custom battery fixture projects.