Product
PXI/PXIe RF Multiplexer, Single 16-Channel, Terminated, 8GHz, 50Ω, SMA
40-883B-002
Multiplexer Module
The 40-883B-002 (PXI) and 42-883B-002 (PXIe) are single 16 to 1 50Ω RF multiplexers with 8GHz bandwidth and automatic termination of unused signal channels. They are available in 8 to 1 and 16 to 1 configurations in two and three slots respectively.
-
Product
PXI/PXIe RF Multiplexer, Single 6-Channel, Terminated, 8GHz, 50Ω, SMA
42-881B-001
Multiplexer Module
The 40/42-881B has low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the module ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
Product
PXI/PXIe RF Multiplexer, Quad 4-Channel, Terminated, 8GHz, 50Ω, SMA
40-882B-004
Multiplexer Module
The 40-882B-004 (PXI) and 42-882B-004 are quad 50Ω 4 to 1 RF multiplexers with 8GHz bandwidth.The 40/42-882B range has automatic termination of unused signals and is available as a single MUX in one slot, a dual MUX in two slots, or triple and quad MUXs in three slots.
-
Product
PXI Dual 4 to 1 RF Multiplexer 2GHz 75 Ohm 1.0/2.3
40-746-731
Multiplexer Module
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
Product
FieldFox Handheld RF and Microwave Analyzers
-
Measure with confidence from 4 to 50 GHz - precise measurements agree with benchtop resultsCapture every signal with real-time spectrum analysis (RTSA) up to 50 GHzWithstands your toughest working environments - rugged enough to meet MIL-specsWeighs less than alternative solutions- millimeter-wave models 30% lighter than other handheldsChoose to configure as a cable and antenna analyzers (CAT), vector network analyzers (VNA), spectrum analyzers and all-in-one combination analyzer
-
Product
PXI Dual 6 to 1 RF Multiplexer 6GHz 50 Ohm SMA Terminated
40-881-002
Multiplexer Module
The 40-881 is a 50 Ohm 6 to 1 6GHz multiplexer available as a single or dual MUX in one and two PXI slots respectively. The 40-881 exhibits low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the 40-881 ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, 3GHz, 50Ω, MCX
40-875A-101
Multiplexer Module
The 40-875A-101 (PXI) and 42-875A-101 (PXIe) are single 50 Ohm 16-channel RF multiplexers in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
RF & Microwave Passive Components
-
SHF Communication Technologies AG
SHF’s microwave components are broadband devices suitable up to 110 GHz. Our SHF BIAS TEES are well known but perhaps a slight variation does suit your application even better. DIPLEXERS are bias tees with a certain bandwidth in the low frequency path to combine or separate high frequency and low frequency signals into or out of a single line. DC-FEEDERS are bias tees without the capacitor. Therefore, it provides slightly lower insertion loss in case it is connected to an AC-coupled device which already has a capacitor on its input. Based on our air line construction, these passive components provide resonance-free transmission over the entire operating range.
-
Product
26-Pin MS-M RF Connector Housing, Female
40-969-526-F
-
These components allow users or their designated cable assembly suppliers to create their own cabling solutions for use with the Souriau MS-M RF connection solution.
-
Product
RF Amplifiers up to 1000 MHz
-
Narrow and Broad band high power RF modules and rack mount amplifier systems using solid state devices including LDMOS and GaAs in Class A and Class A/B topologies for Pulse, AM, FM, continuous wave and digital modulation applications that include EW, Radar, Jamming, EMI and EMC radiated immunity, and wireless communications testing.
-
Product
RF Over IP
-
Quintech Electronics and Communications Inc.
Digital IF / RF Over IP Solutions.
-
Product
RF Safety Monitoring
MVG EME Guard XS 40GHz
-
EME Guard XS 40 GHz has been specifically designed to cover the new 5G millimeter wave bands. This RF safety tool is important for keeping those working close to RF emitters safer. It is easy to use, continuously scanning electromagnetic waves, and alerts the user when acceptable pre-selected limits have been exceeded.
-
Product
PXI/PXIe RF Multiplexer, Single 8-Channel, 3GHz, 75Ω, SMB
40-834A-001
Multiplexer Module
The 40-834A-001 (PXI) and 42-834A-001 (PXIe) are 75 Ohm 8 to 1 RF multiplexers with 1 bank in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
High Load Shear Strength Tester
HLST1000
-
This tester measures the shear force required to analyze the bonding strength of various bonding materials. It is possible to measure shear force up to 5000N for the purpose of bonding strength evaluation over a large area. An optional heating unit enables evaluation while the sample is heated.
-
Product
High Power DC Electronic Load
63200A series
-
The 63200A series high power DC electronic loads are designed for testing a wide range of power conversion products including AC/DC and server power supplies, DC/DC converters, EV batteries, automotive charging stations, and other power electronics components. These units can be synchronously paralleled up to 240kW and dynamically synchronized for generating complex multi-channel transient profiles. The 300% peak overpower capability provides extra headroom for fault condition simulations in automotive batteries, fuel cells, and more. The 63200A series have three operating voltage choices, 150V, 600V & 1,200V, with models covering power levels from 4kW to 24kW and up to 2,000A in a single unit. The DC loads have unique user defined waveform (UDW) capability and external analog modulating input for s imul a t ing re a l-wor ld, cus tom waveforms. Another distinct feature is the dynamic auto-frequency sweep function, which enables detecting a UUTs worst case output deviation across a wide range of current frequencies. In addition, a 255-set of data storage function has been built in for recall of the stored settings at any time. For automated testing, the save and recall functions can save a great deal of time.
-
Product
Load Cell Indicator
-
Morehouse Instrument Company Inc.
This indicator can read mV/V and use free, custom Morehouse software to convert the mV/V units to engineering units with coefficient files from ASTM E74 or ISO 376 reports. This meter is often the choice for accredited calibration service providers that want high accuracy and convenience but do not want to break the bank.
-
Product
Dual 8 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-763-002
Multiplexer Module
This terminated dual 8 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI RF Matrix Switch: 300 MHz, 8x12, 50 Ω
M9128A
Matrix Switch Module
The M9128A, an 8x12 RF switch matrix routes multiple signals up to 300 MHz in a single instance, allowing any combination of channel closures to connect to multiple instruments. Disconnected switches isolate the rows for better overall RF performance. This module also features easy, snap-on SMB connections in a high-performance, bi-directional switch matrix.
-
Product
L-Band RF Tuner and 2-Channel 200 MHz A/D with Virtex-6 FPGA - XMC
Model 71690
-
- Accepts RF Signals from 925 MHz to 2175 MHz- Programmable LNA boosts LNB (low noise block) antenna signal - levels with up to 60 dB gain- Programmable analog downconverter to I + Q baseband signals - 4 to 40 MHz bandwidth- Two 200 MHz 16-bit A/Ds digitize the I + Q signals synchronously- Supports Xilinx Virtex-6 LXT and SXT FPGA- 2 GB DDR3 SDRAM or 32 MB of QDRII+ SRAM- Sample clock synchronization to an external system reference- PCI Express (Gen. 1 & 2) interface, up to x8- Clock/sync bus for multimodule synchronization- VITA 42.0 XMC compatible with switched fabric interfaces- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Low Frequency RF Broadband Power Sources
-
Class A has RF power source, ideal for Industrial /Scientific / Medical applications. Class AS is a robust source of RF power for ultrasonic, laser modulation, RFI/EMI, plasma generation, general laboratory and industrial applications.
-
Product
DC Electronic Loads
-
Keysight DC electronic loads provide you with the flexibility to test a wide range of applications from power-supply test to simulation of high-intensity discharge (HID) headlamps. The 16-bit voltage, current and power-measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.
-
Product
Time Domain Replication (Road Load Simulation)
-
The powerful graphical editor makes it easy to review and compile your field sample data for use in the test lab. The point editor, filters, velocity and displacement compensation ensure the test feasibility is evaluated at an early stage. The continuous closed-loop controller then replicates the test files with very high levels of precision. The control algorithms use a continuous coherence averaging technique to ensure a stable proactive control loop that will not only provide accurate replication but will also respond to changes in test item dynamics.
-
Product
1800~3000W DC Electronic Loads
JT633 series
-
Nanjing Jartul Electronic Co., Ltd
JT633 series electronic load is functioned with 500KHz high-speed synchronous sampling, DSP technology, powerful dynamic test and multi-aspect intelligence analysis. All these are fully integrated into auotmatic test function, which makes JT633 series load very suitable for testing power supply when produced in large quantity. Besides, JT633 series load also possesses the features of current rising slew rate programmable, high-speed dynamic loading and programmable list function, which makes JT633 series load satisfing most of R&D requirements.
-
Product
PXI Dual 8 to 1 RF Multiplexer 3GHz 50 Ohm SMB
40-874-002
Multiplexer Module
The 40-874-002 is a 50 Ohm 8 to 1 RF multiplexer with 2 banks in a single PXI slot. It has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of this RF multiplexer has been minimized by careful attention to the mechanical and electrical design.
-
Product
Static Load Cells (5 N to 300 kN)
2530 Series
-
The Instron 2530 Series static load cells are precision force transducers engineered for versatile use in tension, compression, cyclic, and reverse stress testing, delivering accurate measurements down to 1/500th of their capacity. Individually temperature-compensated and calibrated, they support automatic recognition and electronic calibration, and are built to international force-measurement standards (ASTM E4, ISO 7500-1 class 0.5, and JIS B7721, B7733). With overload protection (150 % of rating without damage, 300 % without mechanical failure), the 2530 family offers consistent, repeatable performance across a wide force range (5 N to 300 kN).2530 Series load cells with capacities of 5 N to 100 N are for use with 3300, 3400, 5900, and 6800 Series testing systems.2530 Series Load cells with capacities of 500 N to 300 kN are for use with 3300 and 3400 Series testing systems.
-
Product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
-
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Product
RF Admittance Level Measurement
-
RF Admittance is one of the most versatile technologies being used today in a wide range of continuous level applications. It has a long standing reputation as a proven technology in the most demanding level process environments.
-
Product
PXI-5651, 3.3 GHz RF Signal Generator
779670-01
Signal Generator
3.3 GHz PXI RF Analog Signal Generator—The PXI‑5651 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5651 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated Common, 3GHz, 50Ω, SMB
40-876A-002
Multiplexer Module
The 40-876A-002 (PXI) and 42-876A-002 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.